Age dependency of sensing performance and AV synchrony in single lead VDD pacing

被引:17
|
作者
Wiegand, UKH [1 ]
Potratz, J [1 ]
Bode, F [1 ]
Schneider, R [1 ]
Peters, W [1 ]
Bonnemeier, H [1 ]
Katus, HA [1 ]
机构
[1] Med Univ Lubeck, Med Klin 2, Dept Internal Med 2, D-23538 Lubeck, Germany
来源
关键词
single lead VDD pacemaker; age; atrial sensing; sinus node function; atrial fibrillation; AV synchrony;
D O I
10.1111/j.1540-8159.2000.tb00856.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Implantation of single lead VDD pacemakers is an established therapeutic option in patients with AV block and normal sinus node function. However, related to occurrence of sinus node disease and atrial undersensing, there is concern whether VDD devices are appropriate in physically active young patients. Two hundred thirty-two consecutive patients with isolated AV block and VDD pacemakers were investigated. This population was subdivided into quartiles of 58 patients according to age at time of inclusion: 26.2-59.4 years (group A), 59.5-70.1 years (group B), 70.2-81.0 years (group C), and 81.1-92.5 years (group D). Follow-up visits included pacemaker telemetry, Holter monitoring, and exercise testing. Patients were visited at 2 and 12 weeks after implantation thereafter followed by 6-month intervals. Mean follow-up period was 35 +/- 14 months. Three months after implantation, atrial sensing threshold was significantly higher in young patients: 1.18 +/- 0.58 mV (group A) versus 0.79 +/- 0.35 mV (group B), 0.68 +/- 0.33 mV(group C), and 0.60 +/- 0.25 mV (group D), P < 0.001 for comparison of group A to all other groups. Atrial undersensing was observed less frequently in young patients: 6.9% (group A) versus 17.2 % (group B), 24.1 % (group C), and 27.6% (group D), P = 0.025 for intergroup comparisons. Sinus node dysfunction did not occur in group A. Atrial arrhythmias and loss of AV synchronized pacing mode occurred rarely in young patients: 0.6% (0.4%) per year in group A versus 1.3% (1.3%) in group B, 3.9% (3.4%) in group C, and 5.7% (7.4%) per year in group D, P < 0.01 for intergroup comparisons. Our data show good atrial sensing performance, low incidence of sinus node dysfunction, and few atrial arrhythmias in young patients with VDD pacing for AV block. Thus, single lead VDD pacing can be recommended particularly for young patients with AV block.
引用
收藏
页码:863 / 869
页数:7
相关论文
共 50 条
  • [1] Age-dependency of sensing performance and AV-synchrony in single-lead VDD-pacing
    Wiegand, UKH
    Potratz, J
    Bonnemeier, H
    Bode, F
    Schneider, R
    Toelg, R
    Peters, W
    CIRCULATION, 1999, 100 (18) : 568 - 568
  • [2] Predictors of loss of atrioventricular synchrony in single lead VDD pacing
    Hunziker, P
    Buser, P
    Pfisterer, M
    Burkart, F
    Osswald, S
    HEART, 1998, 80 (04) : 390 - 392
  • [3] COMPLICATIONS OF SINGLE LEAD VDD PACING IN 35 PATIENTS WITH AV-BLOCK
    PARRAVICINI, U
    ZANETTA, M
    ZENONE, F
    BIELLI, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1901 - 1902
  • [4] Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. Is the occurrence of atrial undersensing predictable?
    Wiegand, UKH
    Schneider, R
    Bode, F
    Brandes, A
    Taubert, G
    Potratz, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1997, 86 (02): : 95 - 104
  • [5] Atrial sensing and AV synchrony in single lead VDD pacemakers: A prospective comparison to DDD devices with bipolar atrial leads
    Wiegand, UKH
    Bode, F
    Schneider, R
    Taubert, G
    Brandes, A
    Peters, W
    Katus, HA
    Potratz, J
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (04) : 513 - 520
  • [6] Echocardiography to predict inappropriate atrial sensing in single lead VDD pacing
    De Cock, CC
    Van Campen, LCMC
    Huygens, J
    Kamp, O
    Visser, CA
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 125 - 129
  • [7] Atrial sensing performance of a single-lead VDD pacing system during physical activities
    Ertas, F
    Karaoguz, R
    Güldal, M
    Kumbasar, D
    Güleç, S
    Oral, D
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (03) : 253 - 260
  • [8] A SINGLE LEAD FOR VDD PACING - A REVIVAL
    ANTONIOLI, GE
    MARZALONI, M
    SERMASI, S
    GIORDANO, M
    RONCAROLO, P
    BINAGHI, G
    BOSCARINI, M
    DEPONTI, C
    GIBELLI, G
    ZANUTTINI, D
    BURELLI, C
    SGARBI, E
    RENZI, R
    SANTINI, M
    FARRIS, W
    TAMARO, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 635 - 635
  • [9] Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. A prospective comparison to DDD-devices.
    Wiegand, UKH
    Bode, F
    Schneider, R
    Brandes, A
    Haase, H
    Potratz, J
    CIRCULATION, 1998, 98 (17) : 427 - 427
  • [10] IS THE HEMODYNAMIC BENEFIT OF VDD PACING DUE TO AV-SYNCHRONY OR TO RATE RESPONSIVENESS
    MUNTEANU, J
    WIRTZFELD, A
    STANGL, K
    ALT, E
    SEIDL, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A75 - A75