Modeling and Simulation of Ventilated Double-Skin Facade Using EnergyPlus

被引:5
|
作者
Le, Sha [1 ]
Chen, Youming [1 ]
Bi, Yuan [1 ]
Lu, Xiang [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
关键词
Double-skin facade systems; EnergyPlus; Airflow network model; Simulation; GLASS DOUBLE FACADES; AIR-FLOW;
D O I
10.1007/978-3-642-39578-9_26
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-skin facade systems (DSF), as one of the newest kind of envelops of buildings, is attracting more and more architects and investors' attention in China. The skins can be air tight or ventilated. As for the ventilated DSF, airflow passing through the cavity can be naturally driven, mechanically driven, or a combination of both. According to some previous studies, buildings constructed with DSF may have better energy performance than the conventional single-skin facade. The problem is that, presently, there are still no official specifications which can help the engineers to thoroughly understand the complex thermal and airflow behavior of DSF. This paper presents a detailed simulation process for an office building equipped with naturally ventilated DSF under the climatic condition in Changsha. A theoretical model is developed via the EnergyPlus simulation program to evaluate the thermal performance of double-skin facade with different configurations. The results obtained in this paper can be valuable for engineers to do some optimization work during the design process under the hot summer and cold winter climates. It indicates that a reasonably constructed DSF can provide an annual saving of around 30 % in building cooling energy, and up to 10 % as for the heating energy, compared to a conventional single-skin facade.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 50 条
  • [31] A summer case study on applying ventilated double-skin facade to a building in cold zone of China
    Yang, Hua
    Wan, Qianzhao
    Yang, Bin
    Sun, Chunhua
    Xia, Guoqiang
    Wang, Jiao
    [J]. PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 1682 - 1685
  • [32] Chimney Effect Assessment of the Double-skin Facade
    QIU ZhongzhuLI PengCHOW TintaiREN JianxingWANG WenhuanSchool of Energy Environment EngineeringShanghai University of Electric PowerShanghai ChinaSchool of Mechanical EngineeringTongji UniversityShanghai ChinaDivision of Building Science TechnologyCity University of Hong KongHong Kong SARChina
    [J]. 湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 146 - 150
  • [33] Chimney Effect Assessment of the Double-skin Facade
    QIU Zhong-zhu1
    2.School of Mechanical Engineering
    3.Division of Building Science & Technology
    [J]. 湖南大学学报(自然科学版), 2009, (S1) : 146 - 150
  • [34] Developing a method and simulation model for evaluating the overall energy performance of a ventilated semi-transparent photovoltaic double-skin facade
    Peng, Jinqing
    Curcija, Dragan C.
    Lu, Lin
    Selkowitz, Stephen E.
    Yang, Hongxing
    Mitchell, Robin
    [J]. PROGRESS IN PHOTOVOLTAICS, 2016, 24 (06): : 781 - 799
  • [35] Numerical simulation of dynamical aspects of natural convection flow in a double-skin facade
    Popa, Catalin
    Ospir, Dan
    Fohanno, Stephane
    Chereches, Cristian
    [J]. ENERGY AND BUILDINGS, 2012, 50 : 229 - 233
  • [36] Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell
    Mateus, Nuno M.
    Pinto, Armando
    da Graca, Guilherme Carrilho
    [J]. ENERGY AND BUILDINGS, 2014, 75 : 511 - 522
  • [37] DOUBLE OR SINGLE SKIN FACADE IN A MODERATE CLIMATE An EnergyPlus Assessment
    Andjelkovic, Aleksandar S.
    Petrovic, Jovan R.
    Kljajic, Miroslav V.
    [J]. THERMAL SCIENCE, 2016, 20 : S1501 - S1510
  • [38] Evaluating thermal performance of double-skin facade using response factor
    Lee, Seung Woo
    Park, J. S.
    [J]. ENERGY AND BUILDINGS, 2020, 209
  • [39] Natural Convection in a PV-Integrated Double-Skin Facade using Large-Eddy Simulation
    Lau, G. E.
    Yeoh, G. H.
    Timchenko, V.
    Yuen, R. K. K.
    [J]. PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [40] Characterization of a naturally ventilated double-skin facade through the design of experiments (DOE) methodology in a controlled environment
    Jankovic, Aleksandar
    Goia, Francesco
    [J]. ENERGY AND BUILDINGS, 2022, 263