Studying Different Operating Conditions on Reverse Osmosis Performance in the Treatment of Wastewater Containing Nickel (II) Ions

被引:5
|
作者
Shigidi, Ihab [1 ]
Harharah, Ramzi H. H. [1 ]
Abdalla, Ghassan M. T. [2 ]
Elkhaleefa, Abubakar [1 ]
Alsaiari, Norah S. S. [3 ]
Harharah, Hamed N. N. [1 ]
Amari, Abdelfattah [1 ,4 ]
Hassan, Mohamed G. G. [5 ]
机构
[1] King Khalid Univ, Coll Engn, Dept Chem Engn, Abha 61421, Saudi Arabia
[2] Univ Khartoum, Fac Engn, Dept Elect & Elect Engn, POB 10179, Khartoum, Sudan
[3] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Dept Chem, POB 84428, Riyadh 11671, Saudi Arabia
[4] Gabes Univ, Natl Sch Engineers, Res Lab Proc Energet Environm & Elect Syst, Gabes 6072, Tunisia
[5] Univ Southampton, Fac Engn & Phys Sci, Chem Engn, Highfield Campus, Southampton SO17 1BJ, England
关键词
reverse osmosis; nickel (II) removal; industrial wastewater; temperature correction factor; mathematical models; HEAVY-METAL IONS; AQUEOUS-SOLUTIONS; REMOVAL; NANOFILTRATION; COMPLEXATION; SEPARATION; EXCHANGE; NI(II);
D O I
10.3390/membranes12111163
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The reverse osmosis performance in removing nickel ions from artificial wastewater was experimentally and mathematically assessed. The impact of temperature, pressure, feed concentration, and feed flow rate on the permeate flux and Ni (II) rejection % were studied. Experiments were conducted using a SEPA CF042 Membrane Test Skid-TFC BW30XFR with applied pressures of 10, 20, 30, and 40 bar and feed concentrations of 25, 50, 100, and 150 ppm with varying operating temperatures of 25, 35, and 45 degrees C, while the feed flow rate was changed between 2, 3.2, and 4.4 L/min. The permeate flux and the Ni (II) removal % were directly proportional to the feed temperature and operating pressure, but inversely proportional to the feed concentration, where the permeate flux increased by 49% when the temperature was raised from 25 to 45 degrees C, while the Ni (II) removal % slightly increased by 4%. In addition, the permeate flux increased by 188% and the Ni (II) removal % increased to 95.19% when the pressure was raised from 10 to 40 bar. The feed flow rate, on the other hand, had a negligible influence on the permeate flux and Ni (II) removal %. The temperature correction factor (TCF) was determined to be directly proportional to the feed temperature, but inversely proportional to the operating pressure; nevertheless, the TCF was unaffected either by the feed flow rate or the feed concentration. Based on the experimental data, mathematical models were generated for both the permeate flux and nickel removal %. The results showed that both models matched the experimental data well.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Laundry Wastewater Treatment Using Ultrafiltration under Different Operating Conditions
    Ashfaq, Mohammad Yousaf
    Qiblawey, Hazim
    RECENT ADVANCES ON ENVIRONMENT, CHEMICAL ENGINEERING AND MATERIALS, 2018, 2022
  • [22] Determination of Optimal Operating Condition in Nanofiltration (NF) and Reverse Osmosis (RO) During the Treatment of a Tannery Wastewater Stream
    Sannino, Diana
    Sacco, Olga
    Chianese, Angelo
    ICHEAP-11: 11TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-4, 2013, 32 : 1993 - 1998
  • [23] Forward osmosis desalination of oil and gas wastewater: Impacts of membrane selection and operating conditions on process performance
    Coday, Bryan D.
    Almaraz, Nohemi
    Cath, Tzahi Y.
    JOURNAL OF MEMBRANE SCIENCE, 2015, 488 : 40 - 55
  • [24] Performance of MVR desalination system with variable operating conditions for wastewater treatment
    Liu, Guangbin
    Zhao, Xiaoyan
    Yang, Qichao
    Zhao, Yuanyang
    Tang, Bin
    Li, Liansheng
    Wang, Le
    DESALINATION AND WATER TREATMENT, 2020, 178 : 21 - 31
  • [25] Treatment of Simulated Radioactive Cobalt Containing Wastewater by Ultra-low Pressure Reverse Osmosis Process
    Zhang W.
    Zhang G.
    Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (01): : 187 - 191
  • [26] Parametric study to enhance performance of wastewater treatment process, by reverse osmosis-photovoltaic system
    Yousra Jbari
    Souad Abderafi
    Applied Water Science, 2020, 10
  • [27] Parametric study to enhance performance of wastewater treatment process, by reverse osmosis-photovoltaic system
    Jbari, Yousra
    Abderafi, Souad
    APPLIED WATER SCIENCE, 2020, 10 (10)
  • [28] Treatment of wastewater reverse osmosis concentrate using alginate-immobilised microalgae: Integrated impact of solution conditions on algal bead performance
    Mohseni, Arash
    Kube, Matthew
    Fan, Linhua
    Roddick, Felicity A.
    CHEMOSPHERE, 2021, 276 (276)
  • [29] Performance evaluation of different wastewater treatment technologies operating in a developing country
    Oliveira, Silvia C.
    von Sperling, Marcos
    JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2011, 1 (01) : 37 - 56
  • [30] The influence of salts on the reverse osmosis performance treating simulated boron-containing low level radioactive wastewater
    Chen, Ding
    Li, Fuzhi
    Zhao, Xuan
    Sun, Yuliang
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2018, 93 (12) : 3607 - 3612