Studying Different Operating Conditions on Reverse Osmosis Performance in the Treatment of Wastewater Containing Nickel (II) Ions

被引:5
|
作者
Shigidi, Ihab [1 ]
Harharah, Ramzi H. H. [1 ]
Abdalla, Ghassan M. T. [2 ]
Elkhaleefa, Abubakar [1 ]
Alsaiari, Norah S. S. [3 ]
Harharah, Hamed N. N. [1 ]
Amari, Abdelfattah [1 ,4 ]
Hassan, Mohamed G. G. [5 ]
机构
[1] King Khalid Univ, Coll Engn, Dept Chem Engn, Abha 61421, Saudi Arabia
[2] Univ Khartoum, Fac Engn, Dept Elect & Elect Engn, POB 10179, Khartoum, Sudan
[3] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Dept Chem, POB 84428, Riyadh 11671, Saudi Arabia
[4] Gabes Univ, Natl Sch Engineers, Res Lab Proc Energet Environm & Elect Syst, Gabes 6072, Tunisia
[5] Univ Southampton, Fac Engn & Phys Sci, Chem Engn, Highfield Campus, Southampton SO17 1BJ, England
关键词
reverse osmosis; nickel (II) removal; industrial wastewater; temperature correction factor; mathematical models; HEAVY-METAL IONS; AQUEOUS-SOLUTIONS; REMOVAL; NANOFILTRATION; COMPLEXATION; SEPARATION; EXCHANGE; NI(II);
D O I
10.3390/membranes12111163
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The reverse osmosis performance in removing nickel ions from artificial wastewater was experimentally and mathematically assessed. The impact of temperature, pressure, feed concentration, and feed flow rate on the permeate flux and Ni (II) rejection % were studied. Experiments were conducted using a SEPA CF042 Membrane Test Skid-TFC BW30XFR with applied pressures of 10, 20, 30, and 40 bar and feed concentrations of 25, 50, 100, and 150 ppm with varying operating temperatures of 25, 35, and 45 degrees C, while the feed flow rate was changed between 2, 3.2, and 4.4 L/min. The permeate flux and the Ni (II) removal % were directly proportional to the feed temperature and operating pressure, but inversely proportional to the feed concentration, where the permeate flux increased by 49% when the temperature was raised from 25 to 45 degrees C, while the Ni (II) removal % slightly increased by 4%. In addition, the permeate flux increased by 188% and the Ni (II) removal % increased to 95.19% when the pressure was raised from 10 to 40 bar. The feed flow rate, on the other hand, had a negligible influence on the permeate flux and Ni (II) removal %. The temperature correction factor (TCF) was determined to be directly proportional to the feed temperature, but inversely proportional to the operating pressure; nevertheless, the TCF was unaffected either by the feed flow rate or the feed concentration. Based on the experimental data, mathematical models were generated for both the permeate flux and nickel removal %. The results showed that both models matched the experimental data well.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Impacts of operating conditions on reverse osmosis performance of pretreated olive mill wastewater
    Ochando-Pulido, J. M.
    Rodriguez-Vives, S.
    Hodaifa, G.
    Martinez-Ferez, A.
    WATER RESEARCH, 2012, 46 (15) : 4621 - 4632
  • [2] A Study of Copper (II) Ions Removal by Reverse Osmosis under Various Operating Conditions
    Harharah, Ramzi H.
    Abdalla, Ghassan M. T.
    Elkhaleefa, Abubakr
    Shigidi, Ihab
    Harharah, Hamed N.
    SEPARATIONS, 2022, 9 (06)
  • [3] Influence of filtration conditions on the performance of nanofiltration and reverse osmosis membranes in dairy wastewater treatment
    Turan, M
    DESALINATION, 2004, 170 (01) : 83 - 90
  • [4] Reverse osmosis filtration for space mission wastewater: membrane properties and operating conditions
    Lee, S
    Lueptow, RM
    JOURNAL OF MEMBRANE SCIENCE, 2001, 182 (1-2) : 77 - 90
  • [5] Applicability of nanofiltration and reverse osmosis for the treatment of wastewater of different origin
    Csefalvay, Edit
    Imre, Peter M.
    Mizsey, Peter
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (02): : 277 - 283
  • [7] Processing of retentates of reverse osmosis treatment of phosphate-containing wastewater
    O. O. Seminskaya
    M. N. Balakina
    D. D. Kucheruk
    Journal of Water Chemistry and Technology, 2017, 39 : 171 - 176
  • [8] Processing of Retentates of Reverse Osmosis Treatment of Phosphate-Containing Wastewater
    Seminskaya, O. O.
    Balakina, M. N.
    Kucheruk, D. D.
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2017, 39 (03) : 171 - 176
  • [9] Effect of operating conditions on the separation of ammonium and nitrate ions with nanofiltration and reverse osmosis membranes
    Koyuncu, I
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2002, 37 (07): : 1347 - 1359
  • [10] Effect of operating conditions on the separation of ammonium and nitrate ions with nanofiltration and reverse osmosis membranes
    Koyuncu, Ismail
    Koyuncu, I. (koyuncu@itu.edu.tr), 1600, Marcel Dekker Inc. (37):