Hand-held dynamometry fixated with a tripod is reliable for assessment of back extensor strength in women with osteoporosis

被引:20
|
作者
Valentin, G. [1 ]
Maribo, T. [2 ,3 ]
机构
[1] Cent Denmark Reg, Publ Hlth & Qual Improvement, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ, Dept Publ Hlth, Aarhus, Denmark
[3] Cent Denmark Reg, MarselisborgCentret, Rehabil Publ Hlth & Qual Improvement, DK-8000 Aarhus, Denmark
关键词
Assessment; Back extensor strength; Hand-held dynamometer; Osteoporosis; Vertebral fractures; QUALITY-OF-LIFE; TRUNK MUSCLE STRENGTH; VERTEBRAL FRACTURES; THORACIC KYPHOSIS; SPINAL MOBILITY; RELIABILITY; EXERCISE; RISK; PAIN; DEFORMITIES;
D O I
10.1007/s00198-014-2743-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An appropriate method to assess back extensor strength in clinical practice has not yet been described. Our results showed that a hand-held dynamometry fixated with a tripod is reliable for assessing back extensor strength in women with osteoporosis. Back strengthening exercises play an important role in the rehabilitation of patients with osteoporotic vertebral fractures. Evaluation of the effect of back strengthening exercises requires a method suitable for use in clinical practice to measure back extensor strength. A hand-held dynamometer (HHD) is quick and easy to handle in clinical practice. Currently, there is a lack of evidence whether a HHD is reliable for assessment of back extensor strength in people with osteoporosis. When using a HHD, it may be difficult for the tester to provide a counter pressure corresponding to the effort of the patient. In order to accommodate this, we have developed a tripod and a belt system, which was used to fixate the HHD. This study examined the intra-tester reliability of back extensor strength assessment in women with osteoporosis using a HHD. Back extensor strength of the participants was measured on two events with 7-day intervals. Test procedures were standardized, and all tests were performed by the same tester. Forty-eight women with osteoporosis and vertebral fractures were included in the analysis. The coefficient of variation was 22 % using a HHD fixated by the tester and 17 % using a HHD fixated with the tripod. ICC was 0.75 (95 % confidence interval (CI), 0.63 and 0.88) when using a HHD with fixated by the tester and 0.90 (95 % CI, 0.84 and 0.95) when using a HHD fixated with the tripod. A HHD fixated with a tripod is reliable for the assessment of back extensor strength in women with osteoporosis and vertebral fractures.
引用
收藏
页码:2143 / 2149
页数:7
相关论文
共 50 条
  • [31] Hand-held dynamometry for assessment of muscle strength in patients with inflammatory myopathies (vol 60, pg 2146, 2021)
    Saygin, Didem
    Oddis, Chester, V
    Moghadam-Kia, Siamak
    Rockette-Wagner, Bonny
    Neiman, Nicole
    Koontz, Diane
    Aggarwal, Rohit
    [J]. RHEUMATOLOGY, 2022, 61 (10) : 4220 - 4220
  • [32] Criterion Validity of Hand-Held Dynamometry to Assess Quadriceps Strength in Patients with Lung Disease
    Burtin, C.
    De Brandt, J.
    Spruit, M. A.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [33] Isometric strength of upper limb muscles in youth using hand-held and hand-grip dynamometry
    Mendez-Rebolledo, Guillermo
    Ruiz-Gutierrez, Arturo
    Salas-Villar, Sebastian
    Guzman-Munoz, Eduardo
    Sazo-Rodriguez, Sergio
    Urbina-Santibanez, Eric
    [J]. JOURNAL OF EXERCISE REHABILITATION, 2022, 18 (03) : 203 - 213
  • [34] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    [J]. ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [35] Assessment of Postural Muscle Strength in Sitting: Reliability of Measures Obtained with Hand-Held Dynamometry in Individuals with Spinal Cord Injury
    Larson, Cathy A.
    Tezak, Wynne Dawley
    Malley, Meghan Sheppard
    Thornton, William
    [J]. JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2010, 34 (01): : 24 - 31
  • [36] Correlation of isokinetic and novel hand-held dynamometry measures of knee flexion and extension strength testing
    Whiteley, Rod
    Jacobsen, Phillip
    Prior, Simon
    Skazalski, Christopher
    Otten, Roald
    Johnson, Amanda
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2012, 15 (05) : 444 - 450
  • [37] Can Clinician-Stabilization with Hand-Held Dynamometry Yield a Reliable Measure of Knee Flexion Torque?
    Larson, Daniel
    Lorenz, Daniel
    Melton, Brittany
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (06): : 1095 - 1103
  • [38] Reliability of hand-held dynamometry and functional strength tests for the lower extremity in children with Cerebral Palsy
    Verschuren, Olaf
    Ketelaar, Marjolijn
    Takken, Tim
    Van Brussel, Marco
    Helders, Paul J. M.
    Gorter, Jan Willem
    [J]. DISABILITY AND REHABILITATION, 2008, 30 (18) : 1358 - 1366
  • [39] Responsiveness of hand-held dynamometry to changes in limb muscle strength: A retrospective investigation of published research
    Bohannon, Richard W.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2009, 17 (04) : 221 - 225
  • [40] Literature reporting normative data for muscle strength measured by hand-held dynamometry: A systematic review
    Bohannon, Richard W.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2011, 19 (03) : 143 - 147