Assessment of coronary calcification using calibrated mass score with two different multidetector computed tomography scanners in the Copenhagen General Population Study

被引:7
|
作者
Fuchs, Andreas [1 ]
Groen, Jaap M. [2 ,7 ]
Arnold, Ben A. [3 ]
Nikolovski, Sasho [2 ]
Knudsen, Andreas D. [1 ]
Kuhl, J. Tobias [1 ]
Nordestgaard, Borge G. [4 ,5 ]
Greuter, Marcel J. W. [2 ]
Kofoed, Klaus F. [1 ,6 ]
机构
[1] Univ Copenhagen, Rigshosp, Ctr Heart, Dept Cardiol, Copenhagen, Denmark
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, NL-9700 AB Groningen, Netherlands
[3] Image Anal, 1380 Burkesville Rd, Columbia, KY USA
[4] Univ Copenhagen, Herlev Hosp, Dept Clin Biochem, DK-1168 Copenhagen, Denmark
[5] Univ Copenhagen, Herlev Hosp, Copenhagen Gen Populat Study, DK-1168 Copenhagen, Denmark
[6] Univ Copenhagen, Rigshosp, Ctr Diagnost, Dept Radiol, Copenhagen, Denmark
[7] OLVG, Dept Med Phys, Amsterdam, Netherlands
关键词
Agatston; Calcium; Multidetector computed tomography; MDCT; Mass score; Population; ITERATIVE IMAGE-RECONSTRUCTION; DUAL-SOURCE CT; ARTERY CALCIUM; DISEASE; REPRODUCIBILITY; ALGORITHMS; DENSITY; EVENTS; IMPACT; MODEL;
D O I
10.1016/j.ejrad.2016.12.033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Population studies have shown coronary calcium score to improve risk stratification in subjects suspected for cardiovascular disease. The aim of this work was to assess the validity of multidetector computed tomography (MDCT) for measurement of calibrated mass scores (MS) in a phantom study, and to investigate inter-scanner variability for MS and Agaston score (AS) recorded in a population study on two different high-end MDCT scanners. Materials and methods: A calcium phantom was scanned by a first (A) and second (B) generation 320-MDCT. MS was measured for each calcium deposit from repeated measurements in each scanner and compared to known physical phantom mass. Random samples of human subjects from the Copenhagen General Population Study were scanned with scanner A (N = 254) and scanner B (N = 253) where MS and AS distributions of these two groups were compared. Results: The mean total MS of the phantom was 32.9 +/- 0.8 mg and 33.1 +/- 0.9 mg (p = 0.43) assessed by scanner A and B respectively - the physical calcium mass was 34.0 mg. Correlation between measured MS and physical calcium mass was R-2 = 0.99 in both scanners. In the population study the median total MS was 16.8 mg (interquartile range (IQR): 3.5-81.1) and 15.8 mg (IQR: 3.8-63.4) in scanner A and B(p = 0.88). The corresponding median total AS were 92 (IQR: 23-471) and 89 (IQR: 40-384) (p = 0.64). Conclusion: Calibrated calcium mass score may be assessed with very high accuracy in a calcium phantom by different generations of 320-MDCT scanners. In population studies, it appears acceptable to pool calcium scores acquired on different 320-MDCT scanners. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [41] Relation of a coronary artery calcium score higher than 400 to coronary stenoses detected using multidetector computed tomography and to traditional cardiovascular risk factors
    Ho, John S.
    FitzGerald, Shannon J.
    Stolfus, Lisa L.
    Wade, Wendy A.
    Reinhardt, Dale B.
    Barlow, Carolyn E.
    Cannaday, John J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (10): : 1444 - 1447
  • [42] Comprehensive assessment of coronary computed tomography angiography by using Leaman and Leiden score in overweight and obese patients
    Nausharwan Butt
    Sabin Parajuli
    Laith Ali
    Omar Yacob
    Gebremedhin D. Melaku
    Alexandre Hideo-Kajita
    Gaby Weissman
    Hector M. Garcia-Garcia
    [J]. The International Journal of Cardiovascular Imaging, 2020, 36 : 2377 - 2382
  • [43] Comprehensive assessment of coronary computed tomography angiography by using Leaman and Leiden score in overweight and obese patients
    Butt, Nausharwan
    Parajuli, Sabin
    Ali, Laith
    Yacob, Omar
    Melaku, Gebremedhin D.
    Hideo-Kajita, Alexandre
    Weissman, Gaby
    Garcia-Garcia, Hector M.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (12): : 2377 - 2382
  • [44] Detection of Coronary Artery Disease Using Coronary Flow Velocity Reserve by Transthoracic Doppler Echocardiography versus Multidetector Computed Tomography Coronary Angiography: Influence of Calcium Score
    Kakuta, Kentaro
    Dohi, Kaoru
    Yamada, Tomomi
    Yamanaka, Takashi
    Kawamura, Masaki
    Nakamori, Shiro
    Nakajima, Hiroshi
    Tanigawa, Takashi
    Onishi, Katsuya
    Yamada, Norikazu
    Nakamura, Mashio
    Ito, Masaaki
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (07) : 775 - 785
  • [45] Stature estimation based on femoral measurements in the modern Japanese population: a cadaveric study using multidetector computed tomography
    Fumiko Chiba
    Yohsuke Makino
    Suguru Torimitsu
    Ayumi Motomura
    Go Inokuchi
    Namiko Ishii
    Yumi Hoshioka
    Hiroko Abe
    Rutsuko Yamaguchi
    Ayaka Sakuma
    Sayaka Nagasawa
    Hisako Saito
    Daisuke Yajima
    Yuta Fukui
    Hirotaro Iwase
    [J]. International Journal of Legal Medicine, 2018, 132 : 1485 - 1491
  • [46] Stature estimation based on femoral measurements in the modern Japanese population: a cadaveric study using multidetector computed tomography
    Chiba, Fumiko
    Makino, Yohsuke
    Torimitsu, Suguru
    Motomura, Ayumi
    Inokuchi, Go
    Ishii, Namiko
    Hoshioka, Yumi
    Abe, Hiroko
    Yamaguchi, Rutsuko
    Sakuma, Ayaka
    Nagasawa, Sayaka
    Saito, Hisako
    Yajima, Daisuke
    Fukui, Yuta
    Iwase, Hirotaro
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2018, 132 (05) : 1485 - 1491
  • [47] The relationship between volumetric thoracic bone mineral density and coronary calcification in men and women - results from the Copenhagen General Population Study
    Wiegandt, Yaffah L.
    Sigvardsen, Per Ejlstrup
    Sorgaard, Mathias H.
    Knudsen, Andreas D.
    Rerup, Sofie Aagaard
    Kuhl, Jurgen Tobias
    Fuchs, Andreas
    Kober, Lars V.
    Nordestgaard, Barge G.
    Kofoed, Klaus F.
    [J]. BONE, 2019, 121 : 116 - 120
  • [48] Normal values of regional left ventricular myocardial thickness, mass and distribution-assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study
    Louise Hindsø
    Andreas Fuchs
    Jørgen Tobias Kühl
    Emma Julia P. Nilsson
    Per Ejlstrup Sigvardsen
    Lars Køber
    Børge G. Nordestgaard
    Klaus Fuglsang Kofoed
    [J]. The International Journal of Cardiovascular Imaging, 2017, 33 : 421 - 429
  • [49] Diagnostic Accuracy of Computed Tomography Coronary Angiography According to Pre-Test Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification The CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) International Multicenter Study
    Arbab-Zadeh, Armin
    Miller, Julie M.
    Rochitte, Carlos E.
    Dewey, Marc
    Niinuma, Hiroyuki
    Gottlieb, Ilan
    Paul, Narinder
    Clouse, Melvin E.
    Shapiro, Edward P.
    Hoe, John
    Lardo, Albert C.
    Bush, David E.
    de Roos, Albert
    Cox, Christopher
    Brinker, Jeffrey
    Lima, Joao A. C.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (04) : 379 - 387
  • [50] Normal values of regional left ventricular myocardial thickness, mass and distribution-assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study
    Hindso, Louise
    Fuchs, Andreas
    Kuhl, Jorgen Tobias
    Nilsson, Emma Julia P.
    Sigvardsen, Per Ejlstrup
    Kober, Lars
    Nordestgaard, Borge G.
    Kofoed, Klaus Fuglsang
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 421 - 429