Color duplex measurement of cerebral blood flow volume in healthy adults

被引:163
|
作者
Scheel, P [1 ]
Ruge, C [1 ]
Petruch, UR [1 ]
Schöning, M [1 ]
机构
[1] Univ Tubingen, Childrens Hosp, Div Child Neurol, D-72076 Tubingen, Germany
关键词
aging; cerebral blood flow; ultrasonography; Doppler; duplex;
D O I
10.1161/01.STR.31.1.147
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Global cerebral blood flow (CBF) is an important yet largely unknown quantity in the treatment of neurological intensive care patients. Color duplex sonography of the extracranial cerebral arteries can be used to measure global CBF volume directly at the bedside. To establish reference data on global CBF volume and to test the influence of sex and age on this parameter, a prospective study was performed in a group of 78 healthy adults aged 20 to 85 years (39 women, 39 men; mean age, 52+/-19 years in either sex). Methods-The common, external, and internal carotid arteries and the vertebral arteries were examined with the use of a 7.0-MHz transducer of a computed sonography system. Angle-corrected time averaged flow velocity and the diameter of the vessel were measured. Intravascular flow volumes were calculated as the product of angle-corrected time-averaged flow velocity and the cross-sectional area of the circular vessel. CBF volume was determined as the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Results-From 20 to 85 years of age, CBF volume decreased significantly (P less than or equal to 0.0001), on average by approximate to 3 mL/min per year. There were no sex-linked differences in CBF volume. The mean relative contributions of the internal carotid artery and the vertebral arteries to global CBF volume remained constant with age (76% versus 24%). The reference data on CBF volume established for the,groups aged 20 to 39 years, 40 to 59 years, and 60 to 85 years were 727+/-102, 656+/-121, and 603+106 mL/min, respectively. Conclusions-The data presented here provide additional information on the natural development of global cerebral perfusion in "benign aging." CBF volume reference data for different age groups were also established. These data provide a basis for the clinical application of CBF volume measurements at the bedside, especially in the monitoring of CBF volume in neurological intensive care patients.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 50 条
  • [41] MEASUREMENT OF CEREBRAL BLOOD-FLOW
    HARPER, AM
    GLASS, HI
    [J]. LANCET, 1963, 1 (729): : 1262 - &
  • [42] Cerebral Blood Flow Measurement in Neurosurgery
    Mette, David
    Strunk, Rhonda
    Zuccarello, Mario
    [J]. TRANSLATIONAL STROKE RESEARCH, 2011, 2 (02) : 152 - 158
  • [43] Measurement of cerebral blood flow at the bedside
    Mélot, C
    Moraine, JJ
    Berré, J
    [J]. ANESTHESIOLOGY, 2000, 93 (06) : 1555 - 1555
  • [44] The landmarks of the measurement of cerebral blood flow
    Nyary Istvan
    [J]. IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2008, 61 (1-2): : 61 - 67
  • [45] Regional cerebral blood flow measurement
    Germann, P
    Urak, G
    Donner, A
    Ullrich, R
    Kneifel, W
    Roder, G
    Zimpfer, M
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 : 37 - 40
  • [46] RADIOISOTOPIC MEASUREMENT OF CEREBRAL BLOOD FLOW
    CRANDALL, PH
    [J]. ARCHIVES OF NEUROLOGY AND PSYCHIATRY, 1958, 80 (04): : 453 - 453
  • [47] Cerebral Blood Flow Measurement in Neurosurgery
    David Mette
    Rhonda Strunk
    Mario Zuccarello
    [J]. Translational Stroke Research, 2011, 2 : 152 - 158
  • [48] MEASUREMENT OF CEREBRAL BLOOD-FLOW
    VEALL, N
    MALLETT, BL
    [J]. LANCET, 1963, 2 (729): : 91 - +
  • [49] Magnetic resonance imaging measurement of blood volume flow in peripheral arteries in healthy subjects
    Klein, WM
    Bartels, LW
    Bax, L
    van der Graaf, Y
    Mali, WPTM
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 38 (05) : 1060 - 1066
  • [50] VOLUME FLOW MEASUREMENT WITH DUPLEX SCANNING IN FEMOROPOPLITEAL BYPASS GRAFTS
    MCSHANE, MD
    GAZZARD, VM
    COTTON, AM
    HUMPHRIES, KN
    CHANT, ADB
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 801 - 801