Spatial variation of radiation quality during moving beam therapy with 14 MeV [d(0.25)+T] neutrons

被引:1
|
作者
Herskind, C
Loncol, T
Höver, KH
机构
[1] German Canc Res Ctr, Dept Radiol, D-69120 Heidelberg, Germany
[2] Catholic Univ Louvain, Dept Radiotherapy, Univ Clin St Luc, B-1200 Brussels, Belgium
关键词
D O I
10.1093/oxfordjournals.rpd.a006804
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In conformal moving beam therapy with fast neutrons, the contributions to dose from the direct beam, scattered radiation and the gamma component vary with the position in the phantom. To determine this variation in radiation quality, microdosimetric measurements of energy deposition spectra were performed at different positions in a therapy phantom. Fixed beam irradiation at different incidence angles showed strong changes in the lineal energy spectrum. An increase of slow protons (20 < y < 110 keV.mum(-1)) and a decrease of fact protons (2 < y < 20 keV.mum(-1)) was seen for irradiation outside the direct beam. During moving beam irradiation, different positions on the same isodose curves (55% or 35%) showed differences in (y) over bar (D) of up to 5%. Variations in the quality parameter. R, determined by applying an empirical biological weighting function, were of similar magnitude. Thus, spatial variations in radiation quality should be taken into account in biological dose planning for moving beam neutron therapy.
引用
收藏
页码:365 / 368
页数:4
相关论文
共 40 条
  • [21] Fission cross-section measurement for 135mXe and 135gXe in 238U reaction induced by 14MeV D-T neutrons
    Wang, Quanxiao
    Wang, Yunyu
    li, Zhonglin
    Niu, Shutong
    Si, Shuyao
    Wang, Qiang
    Zhang, Shuo
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [22] Design and performance validation of a novel 3d printed thin-walled and transparent electron beam applicators for intraoperative radiation therapy with beam energy up to 12 MeV
    Misiarz, Agnieszka
    Lenartowicz, Aleksandra
    Adrich, Przemyslaw
    Rzadkiewicz, Jacek
    Wronka, Slawomir
    Trzuskowski, Jan
    Kruszyna-Mochalska, Marta
    Urbanski, Bartosz
    Adamczyk, Beata
    Pracz, Jacek
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (03) : 329 - 339
  • [23] Intrafractional Prostate Motion and Dose Variation during Radiation Therapy for Prostate Cancer Using 4D-TPUS
    Qi, X.
    Gao, X.
    Zhao, B.
    Qin, S.
    Zhang, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E234 - E234
  • [24] Relationship Between Fatigue, Sleep Quality, and Cytokines During External Beam Radiation Therapy for Prostate Cancer: A Phase 2 Study
    Holliday, E.
    Wood, L. J.
    Dieckmann, N.
    Thomas, C. R., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E191 - E191
  • [25] An investigation into the possibility of performing radiography with gamma rays emitted from water made radioactive by irradiation with 14 MeV D-T fusion neutrons (vol 31, pg 41, 1996)
    Smith, DL
    Ikeda, Y
    Uno, Y
    FUSION ENGINEERING AND DESIGN, 1996, 31 (04) : 333 - 333
  • [26] Intrarectal amifostine during external beam radiation therapy for prostate cancer produces significant improvements in quality of life measured by epic score
    Simone, Nicole L.
    Menard, Cynthia
    Soule, Benjamin P.
    Albert, Paul S.
    Guion, Peter
    Smith, Sharon
    Godette, Denise
    Crouse, Nancy S.
    Sciuto, Linda C.
    Cooley-Zgela, Theresa
    Camphausen, Kevin
    Coleman, C. Norman
    Singh, Anurag K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 90 - 95
  • [27] Relationship between fatigue, sleep quality and inflammatory cytokines during external beam radiation therapy for prostate cancer: A prospective-study
    Holliday, Emma B.
    Dieckmann, Nathan F.
    McDonald, Tasha L.
    Hung, Arthur Y.
    Thomas, Charles R., Jr.
    Wood, Lisa J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (01) : 105 - 111
  • [28] Early evaluation of prostate positioning and movement during external beam radiation therapy using a transperineal 4D ultrasound system
    Pachoud, Marc
    Matzinger, Oscar
    Mazouni, Zohra
    Cosinschi, Adrien
    Godin, Sarah
    Ghandour, Sarah
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 595 - 595
  • [29] Observational study of cone beam computed tomography based interfractional urinary bladder filling variation during image guided radiation therapy in pelvic malignancies
    Shah, Manjari
    Agarwal, Sandeep
    Agarwal, Rashi
    Subramanian, Bala
    Gupta, Sweety
    De, Sudarsan
    Mishra, Shiv
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 152 - 156
  • [30] 3D-MR Spectroscopic Imaging Assessment of Metabolic Status of Malignant Gliomas during External Beam Radiation Therapy - Preliminary Results
    Muruganandham, M.
    Bayouth, J. E.
    Anderson, C. M.
    Smith, M. C.
    Buatti, J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S228 - S229