Novel electrospun poly(ε-caprolactone)/type I collagen nanofiber conduits for repair of peripheral nerve injury

被引:31
|
作者
Yen, Chun-Ming [1 ,2 ]
Shen, Chiung-Chyi [1 ,3 ,4 ]
Yang, Yi-Chin [1 ]
Liu, Bai-Shuan [5 ]
Lee, Hsu-Tung [1 ]
Sheu, Meei-Ling [6 ,7 ,8 ]
Tsai, Meng-Hsiun [9 ]
Cheng, Wen-Yu [1 ,3 ]
机构
[1] Taichung Vet Gen Hosp, Neurol Inst, Dept Neurosurg, Taichung, Taiwan
[2] Natl Chung Hsing Univ, PhD Program Translat Med, Taichung, Taiwan
[3] Hungkuang Univ, Dept Phys Therapy, Taichung, Taiwan
[4] Cent Taiwan Univ Sci & Technol, Basic Med Educ Ctr, Taichung, Taiwan
[5] Cent Taiwan Univ Sci & Technol, Dept Med Imaging & Radiol Sci, Taichung, Taiwan
[6] Natl Chung Hsing Univ, Inst Biomed Sci, Taichung, Taiwan
[7] Taichung Vet Gen Hosp, Dept Med Res, Taichung, Taiwan
[8] Natl Chung Hsing Univ, Rong Hsing Res Ctr Translat Med, Taichung, Taiwan
[9] Natl Chung Hsing Univ, Dept Management Informat Syst, Taichung, Taiwan
关键词
poly(epsilon-caprolactone); type I collagen; electrospinning; sciatic nerve; nerve conduit; immunohistostaining; walking track analysis; peripheral nerve injury; TISSUE; REGENERATION; SCAFFOLD; GUIDES; CELLS;
D O I
10.4103/1673-5374.255997
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Recent studies have shown the potential of artificially synthesized conduits in the repair of peripheral nerve injury. Natural biopolymers have received much attention because of their biocompatibility. To investigate the effects of novel electrospun absorbable poly(epsilon-caprolactone)/type I collagen nanofiber conduits (biopolymer nanofiber conduits) on the repair of peripheral nerve injury, we bridged 10-mm-long sciatic nerve defects with electrospun absorbable biopolymer nanofiber conduits, poly(epsilon-caprolactone) or silicone conduits in Sprague-Dawley rats. Rat neurological function was weekly evaluated using sciatic function index within 8 weeks after repair. Eight weeks after repair, sciatic nerve myelin sheaths and axon morphology were observed by osmium tetroxide staining, hematoxylin-eosin staining, and transmission electron microscopy. S-100 (Schwann cell marker) and CD4 (inflammatory marker) immunoreactivities in sciatic nerve were detected by immunohistochemistry. In rats subjected to repair with electrospun absorbable biopolymer nanofiber conduits, no serious inflammatory reactions were observed in rat hind limbs, the morphology of myelin sheaths in the injured sciatic nerve was close to normal. CD4 immunoreactivity was obviously weaker in rats subjected to repair with electrospun absorbable biopolymer nanofiber conduits than in those subjected to repair with poly(epsilon-caprolactone) or silicone. Rats subjected to repair with electrospun absorbable biopolymer nanofiber conduits tended to have greater sciatic nerve function recovery than those receiving poly(epsilon-caprolactone) or silicone repair. These results suggest that electrospun absorbable poly(epsilon-caprolactone)/type I collagen nanofiber conduits have the potential of repairing sciatic nerve defects and exhibit good biocompatibility. All experimental procedures were approved by Institutional Animal Care and Use Committee of Taichung Veteran General Hospital, Taiwan, China (La-1031218) on October 2, 2014.
引用
收藏
页码:1617 / 1625
页数:9
相关论文
共 50 条
  • [31] Electrospun, Reinforcing Network-Containing, Silk Fibroin-Based Nerve Guidance Conduits for Peripheral Nerve Repair
    Wang, Yaling
    Kong, Yan
    Zhao, Yahong
    Feng, Qilin
    Wu, Yue
    Tang, Xin
    Gu, Xiaosong
    Yang, Yumin
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2016, 6 (01) : 53 - 60
  • [32] Use of nerve conduits for peripheral nerve injury repair A Web of Science-based literature analysis
    Nan, Jinniang
    Hu, Xuguang
    Li, Hongxiu
    Zhang, Xiaonong
    Piao, Renjing
    NEURAL REGENERATION RESEARCH, 2012, 7 (35) : 2826 - 2833
  • [33] Tissue engineered peripheral nerve repair using a novel nanofiber scaffold
    Segovia, Luis A.
    Hokugo, Akishige
    Li, Andrew
    Yalom, Anisa
    Jarrahy, Reza
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (04) : E31 - E32
  • [34] TRILAYERED ALIGNED ELECTROSPUN CONDUITS WITH ENCAPSULATED GDNF AND TACROLIMUS FOR AXONAL GUIDANCE AND REGENERATION IN PERIPHERAL NERVE REPAIR
    Gregory, Holly
    Phillips, James B.
    Roberton, Victoria H.
    Hilton, Stephen
    Williams, Gareth
    TISSUE ENGINEERING PART A, 2022, 28 : S222 - S222
  • [35] Use of nerve conduits for peripheral nerve injury repair:A Web of Science-based literature analysis
    Jinniang Nan
    Xuguang Hu
    Hongxiu Li
    Xiaonong Zhang
    Renjing Piao
    NeuralRegenerationResearch, 2012, 7 (35) : 2826 - 2833
  • [36] Nanofibrous nerve guidance conduits decorated with decellularized matrix hydrogel facilitate peripheral nerve injury repair
    Zheng, Chushan
    Yang, Zehong
    Chen, Shihao
    Zhang, Fang
    Rao, Zilong
    Zhao, Cailing
    Quan, Daping
    Bai, Ying
    Shen, Jun
    THERANOSTICS, 2021, 11 (06): : 2917 - 2931
  • [37] Peripheral Nerve Repair in Rats Using Composite Hydrogel-Filled Aligned Nanofiber Conduits with Incorporated Nerve Growth Factor
    Jin, Jenny
    Limburg, Sonja
    Joshi, Sunil K.
    Landman, Rebeccah
    Park, Michelle
    Zhang, Qia
    Kim, Hubert T.
    Kuo, Alfred C.
    TISSUE ENGINEERING PART A, 2013, 19 (19-20) : 2138 - 2146
  • [38] The influence of electrospun aligned poly(ε-caprolactone)/collagen nanofiber meshes on the formation of self-aligned skeletal muscle myotubes
    Choi, Jin San
    Lee, Sang Jin
    Christ, George J.
    Atala, Anthony
    Yoo, James J.
    BIOMATERIALS, 2008, 29 (19) : 2899 - 2906
  • [39] Nanofiber-Based Multi-Tubular Conduits with a Honeycomb Structure for Potential Application in Peripheral Nerve Repair
    Xue, Jiajia
    Li, Haoxuan
    Xia, Younan
    MACROMOLECULAR BIOSCIENCE, 2018, 18 (09)
  • [40] Electrohydrodynamic Jet 3D Printed Nerve Guide Conduits (NGCs) for Peripheral Nerve Injury Repair
    Vijayavenkataraman, Sanjairaj
    Zhang, Shuo
    Thaharah, Siti
    Sriram, Gopu
    Lu, Wen Feng
    Fuh, Jerry Ying Hsi
    POLYMERS, 2018, 10 (07)