Interruptions and Delivery of Care in the Intensive Care Unit

被引:42
|
作者
Drews, Frank A. [1 ]
Markewitz, Boaz A. [2 ]
Stoddard, Gregory J. [3 ,4 ]
Samore, Matthew H. [5 ]
机构
[1] Univ Utah, Psychol, Salt Lake City, UT USA
[2] Univ Utah, Sch Med, Med, Salt Lake City, UT USA
[3] Univ Utah, Study Design & Biostat Ctr, Salt Lake City, UT USA
[4] Univ Utah, Grad Stat Courses, Salt Lake City, UT USA
[5] Univ Utah, Med, Salt Lake City, UT USA
关键词
interruptions; devices; tasks; patient hazards; HEALTH-CARE; WORKPLACE INTERRUPTIONS; PROSPECTIVE MEMORY; DISPENSING ERRORS; PATIENT SAFETY; NURSES WORK; TASK; COMMUNICATION; SYSTEMS; EMERGENCY;
D O I
10.1177/0018720819838090
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
Objective: This study samples interruption frequency in intensive care unit (ICU) settings to assess the relationship between interruptions and common patient hazards. Background: Task interruptions are accident contributors in numerous industries. Recently, studies on health care interruptions and their impact on patient hazards have received attention. Method: Seven ICUs in four hospitals participated in a 24-month study. Experienced ICU nurses directly observed nursing tasks, interruptions, and patient hazards (delays in care, breaks in device task protocols, and patient safety hazards). Results: During 1,148 hours of observation, 175 nurses performed 74,733 nursing tasks. Interruptions occurred at a rate of 4.95 per hour, and 8.4% of tasks were interrupted. Interruptions originated mostly from humans (65.9%), alarms (24.1%), and others (10%). A total of 774 patient hazards were observed, with a hazard occurring on average every 89 minutes. Relative to noninterrupted tasks, device alarm interrupted nonstructured tasks were associated with increased rates of delays in care and safety hazards (rate ratio [RR] = 3.19). In contrast, rate of delays in care and safety hazards did not increase during human interrupted tasks (RR = 1.13). Rates of protocol nonadherence varied by device type and were highest during artificial airway, medication administration, chest tube, and supplemental oxygen management. Conclusion: Interruptions in the ICU are frequent and contribute to patient hazards, especially when caused by device alarms during nonstructured tasks. Nonadherence to protocols is common and contributed to patient hazards. Application: The findings suggest a need for improvement in task and device design to reduce patient hazards.
引用
收藏
页码:564 / 576
页数:13
相关论文
共 50 条
  • [21] Multidisciplinary obstetric critical care delivery: The concept of the "virtual" intensive care unit
    Leovic, Michael P.
    Robbins, Hailey N.
    Starikov, Roman S.
    Foley, Michael R.
    [J]. SEMINARS IN PERINATOLOGY, 2018, 42 (01) : 3 - 8
  • [22] Team model: Advocating for the optimal method of care delivery in the intensive care unit
    Durbin, CG
    [J]. CRITICAL CARE MEDICINE, 2006, 34 (03) : S12 - S17
  • [23] The Art of Healing Transforming Intensive Care Unit Care Delivery Using a Compassionate Care Approach
    McCray, TaShauna
    [J]. JOURNAL OF HOSPICE & PALLIATIVE NURSING, 2016, 18 (01) : 29 - 38
  • [24] Palliative care and intensive care unit care: Daily intensive care unit care plan checklist #123
    Mularski, Richard A.
    Osborne, Molly L.
    [J]. JOURNAL OF PALLIATIVE MEDICINE, 2006, 9 (05) : 1205 - 1206
  • [25] Epidemiology of Interruptions to Nutrition Support in Critically Ill Children in the Pediatric Intensive Care Unit
    Keehn, Alysha
    O'Brien, Christina
    Mazurak, Vera
    Brunet-Wood, Kim
    Joffe, Ari
    de Caen, Allan
    Larsen, Bodil
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2015, 39 (02) : 211 - 217
  • [26] ENTERAL FEEDING INTERRUPTIONS IN THE PEDIATRIC INTENSIVE CARE UNIT (PICU) - RISK FACTORS AND CONSEQUENCES?
    Hamilton, Susan
    McAleer, Diane
    Naples, Elizabeth
    Mehta, Nilesh
    Leavitt, Kristen
    Mitchell, Paul
    Duggan, Christopher
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (12) : A108 - A108
  • [27] Interruptions During Senior Nurse Handover in the Intensive Care Unit A Quality Improvement Study
    Spooner, Amy J.
    Chaboyer, Wendy
    Aitken, Leanne M.
    [J]. JOURNAL OF NURSING CARE QUALITY, 2019, 34 (01) : E15 - E21
  • [28] Time for Quiet: Reducing Nighttime Interruptions in the Intensive Care Unit (TURN IN-ICU)
    Junker, Christina
    Kesten, Karen
    Ley, Cathaleen
    [J]. NURSING RESEARCH, 2020, 69 (03) : E169 - E170
  • [29] Special Intensive Care The Surgical Intensive Care Unit
    Bhatt, Muneer
    Carpenter, David
    [J]. PHYSICIAN ASSISTANT CLINICS, 2019, 4 (02) : 439 - +
  • [30] Palliative care in the intensive care unit
    Karg, O.
    Geiseler, J.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (49) : 2558 - 2560