A Novel Method to Extend a Partial-Body CT for the Reconstruction of Dose to Organs beyond the Scan Range

被引:12
|
作者
Kuzmin, Gleb A. [1 ]
Mille, Matthew M. [1 ]
Jung, Jae Won [2 ]
Lee, Choonik [3 ]
Pelletier, Christopher [2 ]
Akabani, Gamal [4 ]
Lee, Choonsik [1 ]
机构
[1] NCI, Div Canc Epidemiol & Genet, NIH, Rockville, MD 20850 USA
[2] East Carolina Univ, Dept Phys, Greenville, NC 27858 USA
[3] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[4] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
关键词
EXTERNAL-BEAM; RADIOTHERAPY; PHANTOMS; DOSIMETRY; THERAPY; FAMILY;
D O I
10.1667/RR14999.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Epidemiological investigation is an important approach to assessing the risk of late effects after radiotherapy, and organ dosimetry is a crucial part of such analysis. Computed tomography (CT) images, if available, can be a valuable resource for individualizing the dosimetry, because they describe the specific anatomy of the patient. However, CT images acquired for radiation treatment planning purposes cover only a portion of the body near the target volume, whereas for epidemiology, the interest lies in the more distant normal tissues, which may be located outside the scan range. To address this challenge, we developed a novel method, called the Anatomically Predictive Extension (APE), to extend a partial-body CT image stack using images of a computational human phantom matched to the patient based on their height and weight. To test our method, we created five APE phantoms from chest and abdominal images extracted from the chest-abdomen-pelvis (CAP) CT scans of five patients. Organ doses were calculated for simple chest and prostate irradiations that were planned on the reference computational phantom (assumed patient geometry if no CT images are available), APE phantoms (patient-phantom hybrid given a partial-body patient CT) and full patient CAP CT scans (ground truth). The APE phantoms and patient CAP CT scans resulted in nearly identical dosimetry for those organs that were fully included in the partial-body CT used to construct the APE. The calculated doses to these same organs in the reference phantoms differed by up to 20% and 52% for the chest and prostate cases, respectively. For organs outside the scan coverage, the reference phantom showed, on average, dose differences of 31% (chest case) and 41% (prostate case). For the APE phantoms, these values were 26% (chest) and 17% (prostate). The APE method combines patient and phantom images to improve organ dosimetry both inside and outside the scan range. We intend to use the APE method for estimating dose for organs peripheral to the treatment fields; however, this method is quite generalizable with many potential applications. (C) 2018 by Radiation Research Society
引用
收藏
页码:618 / 626
页数:9
相关论文
共 17 条
  • [11] Dose Reduction in CT Using a Novel Fourier-Based Iterative Reconstruction Method
    Fahimian, B.
    Miao, J.
    Chatziioannou, A.
    DeMarco, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [12] Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition
    Bruder, H.
    Raupach, R.
    Sunnegardh, J.
    Allmendinger, T.
    Klotz, E.
    Stierstorfer, K.
    Flohr, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8567 - 8582
  • [13] A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
    Machida, Haruhiko
    Fukui, Rika
    Tanaka, Isao
    Shen, Yun
    Ishikawa, Takuya
    Tate, Etsuko
    Suzuki, Shigeru
    Ueno, Eiko
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (04) : 217 - 223
  • [14] A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
    Haruhiko Machida
    Rika Fukui
    Isao Tanaka
    Yun Shen
    Takuya Ishikawa
    Etsuko Tate
    Shigeru Suzuki
    Eiko Ueno
    Japanese Journal of Radiology, 2014, 32 : 217 - 223
  • [15] A novel protocol for abdominal low-dose CT scans adapted with a model-based iterative reconstruction method
    Tsai, Meng-Yuan
    Liang, Huei-Lung
    Chuo, Chiung-Chen
    Li, Chia-Wei
    Chen, Ai-Chih
    Hsiao, Chia-Chi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (03) : 453 - 461
  • [16] Impact of total-body PET/CT Scan Duration and Reconstruction Parameters on Absorbed Doses in Y-90 Radioembolisation Patients derived from Dose Maps generated with a Monte-Carlo simulated Dose Kernel
    Linder, P. M.
    Koerner, E.
    Brosch-Lenz, J.
    Dittmann, H.
    la Fougere, C.
    Schmidt, F. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S210 - S211
  • [17] Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study
    Nagayama, Y.
    Nakaura, T.
    Oda, S.
    Tsuji, A.
    Urata, J.
    Furusawa, M.
    Tanoue, S.
    Utsunomiya, D.
    Yamashita, Y.
    CLINICAL RADIOLOGY, 2018, 73 (02) : 217.e7 - 217.e16