A Novel Method to Extend a Partial-Body CT for the Reconstruction of Dose to Organs beyond the Scan Range

被引:12
|
作者
Kuzmin, Gleb A. [1 ]
Mille, Matthew M. [1 ]
Jung, Jae Won [2 ]
Lee, Choonik [3 ]
Pelletier, Christopher [2 ]
Akabani, Gamal [4 ]
Lee, Choonsik [1 ]
机构
[1] NCI, Div Canc Epidemiol & Genet, NIH, Rockville, MD 20850 USA
[2] East Carolina Univ, Dept Phys, Greenville, NC 27858 USA
[3] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[4] Texas A&M Univ, Dept Nucl Engn, College Stn, TX 77843 USA
关键词
EXTERNAL-BEAM; RADIOTHERAPY; PHANTOMS; DOSIMETRY; THERAPY; FAMILY;
D O I
10.1667/RR14999.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Epidemiological investigation is an important approach to assessing the risk of late effects after radiotherapy, and organ dosimetry is a crucial part of such analysis. Computed tomography (CT) images, if available, can be a valuable resource for individualizing the dosimetry, because they describe the specific anatomy of the patient. However, CT images acquired for radiation treatment planning purposes cover only a portion of the body near the target volume, whereas for epidemiology, the interest lies in the more distant normal tissues, which may be located outside the scan range. To address this challenge, we developed a novel method, called the Anatomically Predictive Extension (APE), to extend a partial-body CT image stack using images of a computational human phantom matched to the patient based on their height and weight. To test our method, we created five APE phantoms from chest and abdominal images extracted from the chest-abdomen-pelvis (CAP) CT scans of five patients. Organ doses were calculated for simple chest and prostate irradiations that were planned on the reference computational phantom (assumed patient geometry if no CT images are available), APE phantoms (patient-phantom hybrid given a partial-body patient CT) and full patient CAP CT scans (ground truth). The APE phantoms and patient CAP CT scans resulted in nearly identical dosimetry for those organs that were fully included in the partial-body CT used to construct the APE. The calculated doses to these same organs in the reference phantoms differed by up to 20% and 52% for the chest and prostate cases, respectively. For organs outside the scan coverage, the reference phantom showed, on average, dose differences of 31% (chest case) and 41% (prostate case). For the APE phantoms, these values were 26% (chest) and 17% (prostate). The APE method combines patient and phantom images to improve organ dosimetry both inside and outside the scan range. We intend to use the APE method for estimating dose for organs peripheral to the treatment fields; however, this method is quite generalizable with many potential applications. (C) 2018 by Radiation Research Society
引用
收藏
页码:618 / 626
页数:9
相关论文
共 17 条
  • [1] Dose reconstruction of a Brazilian industrial gamma radiography partial-body overexposure case
    Da Silva, FCA
    Hunt, JG
    Ramalho, AT
    Crispim, VR
    JOURNAL OF RADIOLOGICAL PROTECTION, 2005, 25 (03) : 289 - 298
  • [2] A novel reconstruction algorithm to extend the CT scan field-of-view
    Hsieh, J
    Chao, E
    Thibault, J
    Grekowicz, B
    Horst, A
    McOlash, S
    Myers, TJ
    MEDICAL PHYSICS, 2004, 31 (09) : 2385 - 2391
  • [3] Realistic extension of partial-body pediatric CT for whole-body organ dose estimation in radiotherapy patients
    Rafet, Sergio Morato
    Lee, Choonik
    Griffin, Keith T.
    Saha, Monjoy
    Lee, Choonsik
    Mille, Matthew M.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [4] AN APPRAISAL OF THE VALUE OF THE CONTAMINATED POISSON METHOD TO ESTIMATE THE DOSE INHOMOGENEITY IN SIMULATED PARTIAL-BODY EXPOSURE
    HILALI, A
    LEONARD, ED
    DECAT, G
    LEONARD, A
    RADIATION RESEARCH, 1991, 128 (01) : 108 - 111
  • [5] Dose to Organs Outside of CT Scan Range-Monte Carlo and Hybrid Phantom Approach
    Pelletier, C.
    Lee, C.
    Jung, J.
    Kim, J.
    Lee, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 249 - 249
  • [6] A Look at Radiation Dose Dependence on Subject Size at Locations Across and Beyond CT Scan Range
    Li, X.
    Yang, K.
    Liu, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E599 - E599
  • [7] Organ Dose Estimation in Body CT Examinations Using a Mathematical Model Based On Planar Scan Range Average Dose
    Faghihi, R.
    Sina, S.
    Masoudi, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E546 - E546
  • [8] Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method
    Yu, Lifeng
    Fletcher, Joel G.
    Shiung, Maria
    Thomas, Kristen B.
    Matsumoto, Jane M.
    Zingula, Shannon N.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1026 - 1037
  • [9] Novel Iterative Reconstruction method for optimal dose usage in redundant CT-acquisitions
    Bruder, H.
    Raupach, R.
    Allmendinger, T.
    Kappler, S.
    Sunnegardh, J.
    Stierstorfer, K.
    Flohr, T.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] A novel reconstruction approach combining OSEM and split Bregman method for low dose CT
    Sheng, Jinhua
    Chen, Bin
    Ma, Yangjie
    Shi, Yuchen
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 62 (62)