Calibration of an arbitrarily arranged projection moire system for 3D shape measurement

被引:10
|
作者
Tang, Ying [1 ]
Yao, Jun [1 ]
Zhou, Yihao [1 ]
Sun, Chen [1 ]
Yang, Peng [1 ]
Miao, Hong [2 ]
Chen, Jubing [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Engn Mech, Shanghai 200240, Peoples R China
[2] Univ Sci & Technol China, Dept Mech & Mech Engn, Hefei 230027, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Projection moire; Metrology; Moire techniques; Surface measurements; System calibration; CAMERA CALIBRATION; ACCURACY; TOPOGRAPHY;
D O I
10.1016/j.optlaseng.2017.10.018
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An arbitrarily arranged projection moire system is presented for three-dimensional shape measurement. We develop a model for projection moire system and derive a universal formula expressing the relation between height and phase variation before and after we put the object on the reference plane. With so many system parameters involved, a system calibration technique is needed. In this work, we provide a robust and accurate calibration method for an arbitrarily arranged projection moire system. The system no longer puts restrictions on the configuration of the optical setup. Real experiments have been conducted to verify the validity of this method. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [1] Three-dimensional shape measurement with an arbitrarily arranged projection moire system
    Yao, Jun
    Tang, Ying
    Chen, Jubing
    OPTICS LETTERS, 2016, 41 (04) : 717 - 720
  • [2] Adaptive projection moire method for arbitrarily arranged light path system
    Cai, Tianyu
    Sun, Chen
    Chen, Jubing
    OPTICS LETTERS, 2022, 47 (10) : 2594 - 2597
  • [3] Three-dimensional shape measurement with an arbitrarily arranged fringe projection profilometry system
    Du, Hua
    Wang, Zhaoyang
    OPTICS LETTERS, 2007, 32 (16) : 2438 - 2440
  • [4] Calibration for endoscopic 3D shape measurement with cone beam projection
    Takahashi, Yuta
    Higashiguchi, Takeshi
    Wakayama, Toshitaka
    APPLIED OPTICS, 2024, 63 (12) : 3058 - 3068
  • [5] Flexible global calibration technique for an arbitrarily arranged fringe projection profilometry system
    Yue, Huimin
    Zhao, Biyu
    Wu, Yuxiang
    Li, Mingyang
    OPTICAL ENGINEERING, 2016, 55 (06)
  • [6] Improvement of depth calibration for digital projection 3D measurement system
    Zheng, Peng
    Zhang, Lin-Na
    Wu, Jian-Quan
    Jia, Ying-Feng
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 : 239 - 246
  • [7] Accurate 3D measurement system and calibration for speckle projection method
    Zhu, Feipeng
    Liu, Wenwen
    Shi, Hongjian
    He, Xiaoyuan
    OPTICS AND LASERS IN ENGINEERING, 2010, 48 (11) : 1132 - 1139
  • [8] 3D profile measurement by color pattern projection and system calibration
    Sinlapeecheewa, C
    Takamasu, K
    IEEE ICIT' 02: 2002 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 405 - 410
  • [9] Pre-calibration-free 3D shape measurement method based on fringe projection
    Zhong, Kai
    Li, Zhongwei
    Li, Renfu
    Shi, Yusheng
    Wang, Congjun
    OPTICS EXPRESS, 2016, 24 (13): : 14196 - 14207
  • [10] 3D shape measurement with thermal pattern projection
    Brahm, Anika
    Reetz, Edgar
    Schindwolf, Simon
    Correns, Martin
    Kuehmstedt, Peter
    Notni, Gunther
    ADVANCED OPTICAL TECHNOLOGIES, 2016, 5 (5-6) : 405 - 413