High sensitivity refractive index sensor based on splicing points tapered SMF-PCF-SMF structure Mach-Zehnder mode interferometer

被引:128
|
作者
Wang, Qi [1 ,2 ]
Kong, Lingxin [1 ]
Dang, Yunli [1 ]
Xia, Feng [1 ]
Zhang, Yongwei [1 ]
Zhao, Yong [1 ,2 ]
Hu, Haifeng [1 ]
Li, Jin [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Liaoning, Peoples R China
[2] Northeastern Univ, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Liaoning, Peoples R China
基金
高等学校博士学科点专项科研基金; 美国国家科学基金会; 中国国家自然科学基金;
关键词
Optical fiber sensor; Refractive index measurement; Mach-Zehnder interference; Photonic crystal fiber; High sensitivity; Splicing points taper; PHOTONIC CRYSTAL FIBER;
D O I
10.1016/j.snb.2015.11.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper proposed and studied a Mach-Zehnder mode interferometric refractive index sensor, which is based on splicing points tapered SMF-PCF-SMF (SMF, single-mode fiber; PCF, photonic crystal fiber) structure. For the reason that the effective refractive index of photonic crystal fiber cladding high-order modes near fiber core are more sensitive to surrounding refractive index changes, the refractive index measurement sensitivity of splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer can be enhanced further through tapering the splicing points. Relations between refractive index measurement sensitivity and photonic crystal fiber length and taper waist diameter are studied through numerical simulations and experiments. Simulation and experimental results show that sensitivity will be increased with the increase of photonic crystal fiber length and the decrease of taper waist diameter. In the refractive range of 1.3333-1.3737, splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm and taper waist diameter of 60.4 mu m has refractive index measurement sensitivity of 260.8 nm/RIU, compared with sensitivity of 224.2 nm/RIU of direct splicing SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm, the sensitivity increased by 16.3%. The research shows that the sensing structure is with good linearity and repeatability. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 50 条
  • [31] Optimization of cascaded fiber tapered Mach-Zehnder interferometer and refractive index sensing technology
    Wang, Qi
    Wei, Wenqing
    Guo, Mengjuan
    Zhao, Yong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 222 : 159 - 165
  • [32] High sensitive Mach-Zehnder interferometer for seawater refractive index measurement
    Mu, Xiaoguang
    Yang, Yuqiang
    Wang, Ji
    Bi, Lei
    FERROELECTRICS, 2022, 595 (01) : 27 - 34
  • [33] A High Sensitivity Curvature Sensor Based on Microfiber Mach-Zehnder Interferometer With Tapered Seven-Core Fiber
    Ji, Yancheng
    Sun, Dan
    Chen, Yupei
    Shi, Yuechun
    Cao, Juan
    Zhang, Guoan
    Han, Zhanghua
    Wang, Chinhua
    Zhu, Xiaojun
    IEEE SENSORS JOURNAL, 2021, 21 (21) : 24090 - 24097
  • [34] Highly sensitive strain sensor based on a novel Mach-Zehnder mode interferometer with TCF-PCF-TCF structure
    Dong, Xinran
    Luo, Zhi
    Du, Haifeng
    Sun, Xiaoyan
    Yin, Kai
    Duan, Ji'an
    OPTICS AND LASERS IN ENGINEERING, 2019, 116 : 26 - 31
  • [35] Tapered Mach-Zehnder interferometer based on two mechanically induced long-period fiber gratings as refractive index sensor
    Cardenas-Sevilla, G. A.
    Monzon-Hernandez, D.
    Torres-Gomez, I.
    Martinez-Rios, A.
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (05): : 1516 - 1520
  • [36] High sensitivity temperature sensor using microfiber based Mach-Zehnder interferometer
    Liang, Ruibing
    Sun, Qizhen
    Wo, Jianghai
    Zhang, Jiejun
    Jia, Weihua
    Liu, Deming
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [37] High-sensitivity pressure sensor based on fiber Mach-Zehnder interferometer
    Wu, Yue
    Xu, Yao
    Yang, Yuguang
    Jin, Wenxing
    Jiang, Youchao
    Shen, Ya
    Jian, Shuisheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (10)
  • [38] Improved optical fiber Mach-Zehnder high-sensitivity refractive index sensor
    Wu, Yongfeng
    Liu, Bo
    Nan, Tong
    Wu, Jing
    Mao, Yaya
    Ren, Jianxin
    Zhao, Lilong
    Sun, Tingting
    Wang, Jin
    Han, Yang
    Zhang, Yulan
    OPTIK, 2021, 229
  • [39] Design of highly sensitive refractive index sensor based on silicon photonic Mach-Zehnder interferometer
    Wu, Yiheng
    Zhou, Yutong
    Pan, Jianxing
    Huang, Tianye
    Jin, Shilong
    OPTICS COMMUNICATIONS, 2023, 534
  • [40] All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index
    曹晔
    赵晨
    童峥嵘
    OptoelectronicsLetters, 2015, 11 (06) : 438 - 443