High sensitivity refractive index sensor based on splicing points tapered SMF-PCF-SMF structure Mach-Zehnder mode interferometer

被引:128
|
作者
Wang, Qi [1 ,2 ]
Kong, Lingxin [1 ]
Dang, Yunli [1 ]
Xia, Feng [1 ]
Zhang, Yongwei [1 ]
Zhao, Yong [1 ,2 ]
Hu, Haifeng [1 ]
Li, Jin [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Liaoning, Peoples R China
[2] Northeastern Univ, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Liaoning, Peoples R China
基金
高等学校博士学科点专项科研基金; 美国国家科学基金会; 中国国家自然科学基金;
关键词
Optical fiber sensor; Refractive index measurement; Mach-Zehnder interference; Photonic crystal fiber; High sensitivity; Splicing points taper; PHOTONIC CRYSTAL FIBER;
D O I
10.1016/j.snb.2015.11.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper proposed and studied a Mach-Zehnder mode interferometric refractive index sensor, which is based on splicing points tapered SMF-PCF-SMF (SMF, single-mode fiber; PCF, photonic crystal fiber) structure. For the reason that the effective refractive index of photonic crystal fiber cladding high-order modes near fiber core are more sensitive to surrounding refractive index changes, the refractive index measurement sensitivity of splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer can be enhanced further through tapering the splicing points. Relations between refractive index measurement sensitivity and photonic crystal fiber length and taper waist diameter are studied through numerical simulations and experiments. Simulation and experimental results show that sensitivity will be increased with the increase of photonic crystal fiber length and the decrease of taper waist diameter. In the refractive range of 1.3333-1.3737, splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm and taper waist diameter of 60.4 mu m has refractive index measurement sensitivity of 260.8 nm/RIU, compared with sensitivity of 224.2 nm/RIU of direct splicing SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm, the sensitivity increased by 16.3%. The research shows that the sensing structure is with good linearity and repeatability. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 50 条
  • [1] High sensitivity for toxic metal ion sensor based on tapered PCF Mach-Zehnder interferometer
    Jassam, Ghufran Mohammed
    Ahmed, Soudad S.
    JOURNAL OF OPTICS-INDIA, 2024, 53 (02): : 1079 - 1085
  • [2] Temperature Insensitive Vector Bending Sensor Based on Asymmetrical Cascading SMF-PCF-SMF Structure
    Fu, Guangwei
    Li, Yunpu
    Li, Qifeng
    Yang, Jiandong
    Fu, Xinghu
    Bi, Weihong
    IEEE PHOTONICS JOURNAL, 2017, 9 (03):
  • [3] Mach-Zehnder interferometer for multi-parameter measurement sensor based on SMF-NCF-FMF-NCF-SMF
    Wu, Meng
    Zhang, Weihua
    Tong, Zhengrong
    Wang, Xue
    Zhao, Yeming
    Zhang, Jietong
    Yan, Gangxiao
    OPTIK, 2022, 249
  • [4] Refractive index Mach-Zehnder interferometer sensor based on tapered no-core fiber
    Zhao, Yeming
    Tong, Zhengrong
    Zhang, Weihua
    Zhang, Jietong
    Li, Jiaxin
    Wang, Xue
    LASER PHYSICS, 2021, 31 (04)
  • [5] A high sensitivity refractive index sensor based on photonic crystal fibre Mach-Zehnder interferometer
    Wang, Qi
    Zhao, Wanming
    Wang, Botao
    Hu, Haifeng
    Li, Jin
    JOURNAL OF MODERN OPTICS, 2017, 64 (16) : 1639 - 1647
  • [6] Ultracompact and high sensitive refractive index sensor based on Mach-Zehnder interferometer
    Yu, Huaqing
    Xiong, Liangbin
    Chen, Zhihong
    Li, Qianguang
    Yi, Xunong
    Ding, Yu
    Wang, Feng
    Lv, Hao
    Ding, Yaoming
    OPTICS AND LASERS IN ENGINEERING, 2014, 56 : 50 - 53
  • [7] Refractive index interferometer based on SMF-MMF-TMCF-SMF structure with low temperature sensitivity
    Cheng, Pu
    Yang, Minghong
    Hu, Wenbin
    Guo, Donglai
    Du, Cheng
    Luo, Xiaoqiao
    Mumtaz, Farhan
    OPTICAL FIBER TECHNOLOGY, 2020, 57
  • [8] High sensitivity for toxic metal ion sensor based on tapered PCF Mach–Zehnder interferometer
    Ghufran Mohammed Jassam
    Soudad S. Ahmed
    Journal of Optics, 2024, 53 : 1079 - 1085
  • [9] A refractive index sensor of PCF Mach-Zehnder interferometer based on CO2 laser fusion technology
    School of Information Science and Engineering, Yanshan University, Qinhuangdao , China
    不详
    Fu, Guang-Wei, 1657, Board of Optronics Lasers (25):
  • [10] An Ultra-High Sensitivity Optical Fiber Refractive Index Sensor Based on Plasmonic Mach-Zehnder Interferometer
    Zhou, Xue
    Li, Xuegang
    Yan, Xin
    Zhang, Xuenan
    Wang, Fang
    Suzuki, Takenobu
    Ohishi, Yasutake
    Cheng, Tonglei
    IEEE PHOTONICS JOURNAL, 2021, 13 (04):