Influence of DIR algorithms on correspondence model-based 4D dose accumulation for lung/liver SBRT

被引:0
|
作者
Sothmann, T. [1 ,2 ]
Mogadas, N. [1 ]
Gauer, T. [2 ]
Werner, R. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf UKE, Dept Computat Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf UKE, Dept Radiotherapy & Radiooncol, Hamburg, Germany
关键词
D O I
10.1016/S0167-8140(18)32431-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-2122
引用
下载
收藏
页码:S1168 / S1168
页数:1
相关论文
共 50 条
  • [21] 4D Model-Based Iterative Reconstruction from Interlaced Views
    Mohan, K. Aditya
    Venkatakrishnan, S. V.
    Gibbs, John W.
    Gulsoy, E. Begum
    Xiao, Xianghui
    De Graef, M.
    Voorhees, Peter W.
    Bouman, Charles A.
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 783 - 787
  • [22] Inter- and intrafractional 4D dose accumulation for evaluating ANTCP robustness in lung cancer
    Smolders, Andreas
    Hengeveld, Adriaan C.
    Both, Stefan
    Wijsman, Robin
    Langendijk, Johannes A.
    Weber, Damien C.
    Lomax, Anthony J.
    Albertini, Francesca
    Marmitt, Gabriel Guterres
    RADIOTHERAPY AND ONCOLOGY, 2023, 182
  • [23] Investigating the Impact of Model-Based Dose Calculation on Interstitial Lung Brachytherapy and Comparison to External Beam SBRT
    O'Connell, D.
    Chang, A.
    Lee, A.
    Venkat, P.
    Hagio, M.
    Yang, Y.
    Park, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E367 - E367
  • [24] Model of lung respiratory movement based on 4D CT
    Liang, Rui
    Zhang, Jianxun
    Feng, Changli
    Zhao, Roger
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2015, 48 (04): : 298 - 304
  • [25] Using 4D dose accumulation to calculate organ-at-risk dose deviations from motion-synchronized liver and lung tomotherapy treatments
    Ferris, William S.
    Chao, Edward H.
    Smilowitz, Jennifer B.
    Kimple, Randall J.
    Bayouth, John E.
    Culberson, Wesley S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [26] 4D-CT Artifacts influence the local Control of an SBRT of Lung and Liver Metastases
    Sentker, T.
    Schmidt, V
    Petersen, C.
    Madesta, F.
    Hofmann, C.
    Werner, R.
    Gauer, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (SUPPL 1) : S43 - S44
  • [27] 4D patient dose reconstruction using online measured EPID cine images for lung SBRT treatment validation
    Lin, Mu-Han
    Li, Jinsheng
    Wang, Lu
    Koren, Sion
    Fan, Jiajing
    Forkal, Eugene
    Ma, C. -M.
    MEDICAL PHYSICS, 2012, 39 (10) : 5949 - 5958
  • [28] Development of a Clinically Feasible Workflow of 4D MRI-Based Treatment Planning for Liver SBRT
    Han, S.
    Yin, F.
    Czito, B.
    Palta, M.
    Cai, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3588 - 3588
  • [29] Method for a motion model based automated 4D dose calculation
    Ziegler, Marc
    Brandt, Tobias
    Lettmaier, Sebastian
    Fietkau, Rainer
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [30] Evaluation of dosimetric misrepresentations from 3D conventional planning of liver SBRT using 4D deformable dose integration
    Yeo, Unjin A.
    Taylor, Michael L.
    Supple, Jeremy R.
    Siva, Shankar
    Kron, Tomas
    Pham, Daniel
    Franich, Rick D.