Data Driven Chiller Sequencing for Reducing HVAC Electricity Consumption in Commercial Buildings

被引:20
|
作者
Zheng, Zimu [1 ]
Chen, Qiong [2 ]
Fan, Cheng [3 ]
Guan, Nan [1 ]
Vishwanath, Arun [4 ]
Wang, Dan [1 ]
Liu, Fangming [2 ]
机构
[1] Hong Kong Polytech Univ, Hong Kong, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan, Hubei, Peoples R China
[3] Shenzhen Univ, Shenzhen, Peoples R China
[4] IBM Res Australia, Melbourne, Vic, Australia
基金
中国国家自然科学基金;
关键词
HVAC Operation; Chiller Sequencing; Applied Machine Learning; SYSTEM; OPTIMIZATION; UNCERTAINTY; ROBUSTNESS;
D O I
10.1145/3208903.3208913
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It is well-known that the HVAC (heating, ventilation and air conditioning) dominates electricity consumption in commercial buildings. Alongside, electricity prices are increasing in several nations around the world, putting pressure on facility managers to reduce the electricity consumption incurred in operating their HVAC and buildings. In this paper, we focus on one of the core problems in building operation, namely chiller sequencing for reducing HVAC electricity consumption. Our contributions are threefold. First, we make a case for why it is important to quantify the performance profile of a chiller, namely coefficient of performance (COP), at run-time, by developing a data-driven COP estimation methodology. Second, we show that predicting COP accurately is a non-trivial problem, requiring considerable computation time. To overcome this barrier, we develop a dominant-graph based COP prediction technique and a time-constrained chiller sequencing algorithm integrating the COP predictions, which strikes a good balance between electricity consumption reduction and ease of use for real-world deployment. Finally, we evaluate the performance of our scheme by applying it to real-world data, spanning 4 years, obtained from multiple chillers across 3 large commercial buildings in Hong Kong. The results show that our solution is able to save on average 21 MWh of electricity consumption in each of the 3 buildings, which is an improvement of over 30% compared to the current mode of operation of the chillers in the buildings. We offer our data-driven chiller sequencing framework under time constraints as an effective and practical mechanism for reducing the electricity consumption associated with HVAC operation in commercial buildings.
引用
下载
收藏
页码:236 / 248
页数:13
相关论文
共 50 条
  • [21] On the Performance of Data-Driven Reinforcement Learning for Commercial HVAC Control
    Faddel, Samy
    Tian, Guanyu
    Zhou, Qun
    Aburub, Haneen
    2020 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2020,
  • [22] Water consumption in absorption chillers is not negligible: Water-for-cooling consumption of chiller systems for commercial buildings in the United States
    Broesicke, Osvaldo A.
    Thomas, Valerie M.
    Grubert, Emily
    Crittenden, John C.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2024, 67
  • [23] CHARACTERISTICS OF ELECTRICITY CONSUMPTION IN COMMERCIAL BUILDINGS - SURVEY OF ELECTRICITY CONSUMPTION IN FULLY AIR-CONDITIONED OFFICE BUILDINGS AND HOTELS IN HONG-KONG, IMPLICATIONS FOR ENERGY-CONSERVATION IN BUILDINGS
    LAM, JC
    CHAN, ALS
    BUILDING RESEARCH AND INFORMATION, 1994, 22 (06): : 313 - 318
  • [24] Data mining algorithm and framework for identifying HVAC control strategies in large commercial buildings
    Chen, Zhe
    Xu, Peng
    Feng, Fan
    Qiao, Yifan
    Luo, Wei
    BUILDING SIMULATION, 2021, 14 (01) : 63 - 74
  • [25] Data mining algorithm and framework for identifying HVAC control strategies in large commercial buildings
    Zhe Chen
    Peng Xu
    Fan Feng
    Yifan Qiao
    Wei Luo
    Building Simulation, 2021, 14 : 63 - 74
  • [26] A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
    Pickering, Ethan M.
    Hossain, Mohammad A.
    Mousseau, Jack P.
    Swanson, Rachel A.
    French, Roger H.
    Abramson, Alexis R.
    PLOS ONE, 2017, 12 (10):
  • [27] Sensitivity to electricity consumption in urban business and commercial area buildings according to climatic change
    Kang-guk Lee
    Sung-bum Kim
    Won-hwa Hong
    Journal of Central South University, 2012, 19 : 770 - 776
  • [28] Predicting electricity consumption for commercial and residential buildings using deep recurrent neural networks
    Rahman, Aowabin
    Srikumar, Vivek
    Smith, Amanda D.
    APPLIED ENERGY, 2018, 212 : 372 - 385
  • [29] Sensitivity to electricity consumption in urban business and commercial area buildings according to climatic change
    Lee Kang-guk
    Kim Sung-bum
    Hong Won-hwa
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2012, 19 (03): : 770 - 776
  • [30] Development of envelope efficiency labels for commercial buildings: Effect of different variables on electricity consumption
    Carlo, Joyce
    Lamberts, Roberto
    ENERGY AND BUILDINGS, 2008, 40 (11) : 2002 - 2008