Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes

被引:23
|
作者
Kleine, P [1 ]
Perthel, M [1 ]
Hasenkam, JM [1 ]
Nygaard, H [1 ]
Hansen, SB [1 ]
Laas, J [1 ]
机构
[1] Herz Kreislauf Klin Bevensen, Dept Cardiothorac Surg, D-29549 Bad Bevensen, Germany
关键词
high intensity transient signals; prosthetic heart valves; Medtronic; St. Jude Medical;
D O I
10.1016/S1010-7940(99)00351-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: High intensity transient signals (HITS) representing microembolization to the brain have been found to contribute to cognitive impairment and psychoneurological dysfunction in patients carrying a mechanical aortic valve. It is unknown, whether HITS represent gaseous or solid emboli. This animal study evaluates the impact of valve orientation on HITS fur two different mechanical valves with both valves implanted in their best and worst orientation, which has been defined in previous studies with respect to downstream turbulence. Methods: In four pigs a rotation device carrying either a Medtronic Hall (MH) or St. Jude Medical (SJM) valve size 23 mm was implanted. The device allowed rotation of the implanted valves without reopening of the aorta. Approximately 30 min after weaning from extracorporeal circulation, a Doppler probe was placed on both common carotid arteries. Tn different orientations of the implanted valves (best and worst position), HITS were detected by the Doppler probe and recorded for ten min by a transcranial Doppler sonography device (Medilab Inc., Estenfeld, Germany). Results: HITS showed significant change with rotation for both valve designs. With the major orifice of the MH oriented towards the non-coronary leaflet (optimum position) very low HITS-counts (0.8-1.7/min) were observed. In the worst orientation HITS rose to 43-66/min. For the SJM the HITS count in the optimum position was 23.4-24/min and in the worst orientation 38-48/min. Conclusions: Valve orientation has an important impact on microembolization to the brain. In the optimum orientation (large orifice facing the non-coronary leaflet) the Medtronic Hall valve showed neglectible incidence of HITS. The St. Jude Medical bileaflet valve showed less variation but demonstrated significant HITS counts at any orientation. As the MH in the worst position shows significantly higher turbulent stresses than the SJM but no higher incidence of HITS, a strong correlation between turbulence and HITS was not demonstrated by this study. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 50 条
  • [41] Platelet aggregation and high-intensity transient signals (HITS) in a sheep model of mitral valve replacement
    Raco, L
    Belcher, PR
    Sim, I
    McGarrity, A
    Bernacca, GM
    Wheatley, DJ
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 476 - 480
  • [42] Reoperative valve replacement with the St. Jude Medical valve prosthesis: Long-term follow-up
    Emery, RW
    Arom, KV
    Krogh, C
    Joyce, LD
    Nicoloff, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 438A - 438A
  • [43] Multiple mechanical valve replacement surgery comparison of St. Jude Medical and CarboMedics prostheses
    Jamieson, WRE
    Munro, AI
    Miyagishima, RT
    Grunkemeier, GL
    Burr, LH
    Lichtenstein, SV
    Tyers, GFO
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (02) : 151 - 159
  • [44] The small aortic root and the Medtronic Hall valve: Ultrafast computed tomography assessment of left ventricular mass following aortic valve replacement
    Anderson, WA
    Ilkowski, DA
    Eldredge, J
    Cha, R
    Chen, C
    Waters, D
    Mahan, VL
    Anolik, G
    Laub, GW
    Fernandez, J
    McGrath, LB
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 : S329 - S335
  • [45] St. Jude Medical prosthetic aortic valve malfunction due to pannus formation.
    Naito Y.
    Hachida M.
    Shimabukuro T.
    Nonoyama M.
    Endo M.
    Koyanagi H.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2000, 48 (11): : 739 - 741
  • [46] Early Results of the Investigational St. Jude Medical Trifecta™ Pericardial Aortic Valve Bioprosthesis
    Bavaria, J. E.
    Szeto, W. Y.
    Burtch, K. E.
    Moyer, E. P.
    Morris, R. J.
    Desai, N. D.
    CARDIOLOGY, 2010, 115 (04) : 253 - 253
  • [47] Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve
    Bach, DS
    Sakwa, MP
    Goldbach, M
    Petracek, MR
    Emery, RW
    Mohr, FW
    ANNALS OF THORACIC SURGERY, 2002, 74 (06): : 2003 - 2009
  • [48] Impact of size mismatch and left ventricular function on performance of the St. Jude disc valve after aortic valve replacement
    Lund, O
    Emmertsen, K
    Nielsen, TT
    Jensen, FT
    Flo, C
    Pilegaard, HK
    Rasmussen, BS
    Hansen, OK
    Kristensen, LH
    ANNALS OF THORACIC SURGERY, 1997, 63 (05): : 1227 - 1234
  • [49] Intracranial high-intensity transient signals after homograft or mechanical aortic valve replacement
    Lievense, AM
    Bakker, SLM
    Dippel, DWJ
    Taams, MA
    Koudstaal, PJ
    Bogers, AJJC
    JOURNAL OF CARDIOVASCULAR SURGERY, 1998, 39 (05): : 613 - 617
  • [50] Late-term results of mitral valve replacement with St. Jude medical® mechanical valve prosthesis:: Samsun experience
    Demirag, Mustafa Kemal
    Keceligil, Hasan Tahsin
    Kolbakir, Fersat
    ACTA CARDIOLOGICA, 2006, 61 (05) : 537 - 544