Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept

被引:62
|
作者
Sailer, Irena [1 ]
Asgeirsson, Asgeir G. [2 ]
Thoma, Daniel S. [2 ]
Fehmer, Vincent [1 ]
Aspelund, Thor [3 ]
Ozcan, Mutlu [2 ]
Pjetursson, Bjarni E. [1 ,4 ]
机构
[1] Univ Geneva, Div Fixed Prosthodont & Biomat, Univ Clin Dent Med, Geneva, Switzerland
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Zurich, Switzerland
[3] Univ Iceland, Publ Hlth Sci, Reykjavik, Iceland
[4] Univ Iceland, Clin Reconstruct Dent, Fac Odontol, Reykjavik, Iceland
关键词
aging; bending moment; hybrid abutment; implant abutment; implant abutment connection; titanium resin base; zirconia abutment; CONTROLLED CLINICAL-TRIAL; ALL-CERAMIC RESTORATIONS; IN-VITRO; BENDING MOMENTS; SINGLE CROWNS; RESISTANCE; FAILURE; REGIONS; CANINE; COLOR;
D O I
10.1111/clr.13139
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThere is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. ObjectivesTo compare the fracture strength of narrow diameter abutments with different types of implant abutment connections after chewing simulation. Material and methodsHundred and twenty identical customized abutments with different materials and implant abutment connections were fabricated for five groups: 1-piece zirconia abutment with internal connection (T1, Cares-abutment-Straumann BL-NC implant, Straumann Switzerland), 1-piece zirconia abutment with external hex connection (T2, Procera abutment-Branemark NP implant, Nobel Biocare, Sweden), 2-piece zirconia abutments with metallic insert for internal connection (T3, Procera abutment-Replace NP implant, Nobel Biocare), 2-piece zirconia abutment on titanium resin base (T4, LavaPlus abutment-VarioBase-Straumann BL-NC implant, 3M ESPE, Germany) and 1-piece titanium abutment with internal connection (C, Cares-abutment-Straumann BL-NC implant, Straumann, Switzerland). All implants had a narrow diameter ranging from 3.3 to 3.5mm. Sixty un-restored abutments and 60 abutments restored with glass-ceramic crowns were tested. Mean bending moments were compared using ANOVA with p-values adjusted for multiple comparisons using Tukey's procedure. ResultsThe mean bending moments were 52133Ncm (T4), 404 +/- 36Ncm (C), 311 +/- 106Ncm (T1) 265 +/- 22Ncm (T3) and 225 +/- 29 (T2) for un-restored abutments and 278 +/- 84Ncm (T4), 302 +/- 170Ncm (C), 190 +/- 55Ncm (T1) 80 +/- 102Ncm (T3) and 125 +/- 57 (T2) for restored abutments. For un-restored abutments, C and T4 had similar mean bending moments, significantly higher than those of the three other groups (p<.05). Titanium abutments (C) had significantly higher bending moments than identical zirconia abutments (T1) (p<.05). Zirconia abutments (T1) with internal connection had higher bending moments than zirconia abutments with external connection (T2) (p<.05). For all test groups, the bending moments were significantly reduced when restored with all-ceramic crowns. ConclusionsFor narrow diameter abutments, the fracture strength of 2-piece internal connected zirconia abutments fixed on titanium resin bases was similar to those obtained for 1-piece titanium abutments. Narrow diameter zirconia abutments with internal connection exhibited higher fracture strength than zirconia abutments with an external connection. Titanium abutments with an internal connection were significantly stronger than identical zirconia abutments.
引用
收藏
页码:411 / 423
页数:13
相关论文
共 40 条
  • [21] Abutment Screw Loosening in Single Implant Restorations: Evaluation of Fracture Strength of Implant-Supported Cement- Retained Monolithic Zirconia Restorations Repaired with Porcelain and Composite Resin
    Asli, Hamid Neshandar
    Falahchai, Mehran
    Rahimabadi, Samiye
    Arbab, Hamidreza
    Mehr, Zoheir Mousavi
    DENTAL HYPOTHESES, 2021, 12 (03): : 128 - 131
  • [22] Mechanical stability of posterior implant-supported monolithic zirconia cantilever on titanium-base abutments. An in vitro study
    Riera, Carme
    Karasan, Duygu
    Sailer, Irena
    Mojon, Phillipe
    Fehmer, Vincent
    Pitta, Joao
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 1042 - 1053
  • [23] Influence of the Titanium Base Abutment Design on Monolithic Zirconia Multiple-Unit Implant Fixed Dental Prostheses: A Laboratory Study
    Calderon, Ulises
    Hicklin, Stefan Paul
    Mojon, Philippe
    Fehmer, Vincent
    Nesic, Dobrila
    Mekki, Mustapha
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 19 - 29
  • [24] Three-Dimensional Deformation and Wear of Internal Implant-Abutment Connection: A Comparative Biomechanical Study Using Titanium and Zirconia
    Nam, Rae-Kyeong
    Lee, Sang J.
    Park, Eun-Jin
    Kwon, Ho-Beom
    Yoon, Hyung-In
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1279 - 1286
  • [25] The Effect of Tissue Entrapment on Screw Loosening at the Implant/Abutment Interface of External- and Internal-Connection Implants: An In Vitro Study
    Zeno, Helios A.
    Buitrago, Renan L.
    Sternberger, Sidney S.
    Patt, Marisa E.
    Tovar, Nick
    Coelho, Paulo
    Kurtz, Kenneth S.
    Tuminelli, Frank J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (03): : 216 - 223
  • [26] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [27] Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    MATERIALS, 2021, 14 (17)
  • [28] Impact of cement type and abutment height on pull-off force of zirconia reinforced lithium silicate crowns on titanium implant stock abutments: an in vitro study
    Lisa Müller
    Angelika Rauch
    Daniel R. Reissmann
    Oliver Schierz
    BMC Oral Health, 21
  • [29] Impact of cement type and abutment height on pull-off force of zirconia reinforced lithium silicate crowns on titanium implant stock abutments: an in vitro study
    Mueller, Lisa
    Rauch, Angelika
    Reissmann, Daniel R.
    Schierz, Oliver
    BMC ORAL HEALTH, 2021, 21 (01)
  • [30] Clinical, Technical, and Radiologic Outcomes of 182 Implant-Supported Zirconia Single Crowns Using Titanium-Base Abutments: A Retrospective Study
    Guncu, Mustafa Baris
    Aktas, Guliz
    Guncu, Guliz N.
    Anil, Duygu
    Turkyilmaz, Ilser
    Antonoff, Lisa R.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (04) : 553 - 559