In-service evaluation of a reinforced concrete T-beam bridge FRP strengthening system

被引:20
|
作者
Hag-Elsafi, O [1 ]
Alampalli, S [1 ]
Kunin, J [1 ]
机构
[1] New York State Dept Transportat, Transportat Res & Dev Bur, Albany, NY 12232 USA
关键词
FRP strengthening system;
D O I
10.1016/j.compstruct.2003.08.002
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In November 1999, bonded fiber-reinforced polymer (FRP) laminates were used to strengthen a single span, reinforced concrete T-beam bridge in New York State. The laminate system was installed to strengthen the structure in flexure and shear, and to contain observed freeze-thaw cracking. The bridge was then instrumented and load tested before and after installation of the laminates, to evaluate effectiveness of the strengthening FRP system. In November 2001, the load test was repeated to monitor in-service performance of the system. The test results indicated that the quality of bond between the laminates and concrete, and effectiveness of the system have not deteriorated after two years of service. Further inspection using an Infrared thermography camera did not show any significant delamination in the system, in agreement with the test results. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 188
页数:10