Effect of intraocular lens design on migration of lens epithelial cells onto the posterior capsule

被引:61
|
作者
Nagamoto, T [1 ]
Eguchi, G [1 ]
机构
[1] NATL INST BASIC BIOL,DEPT DEV BIOL,DIV MORPHOGENESIS,OKAZAKI,AICHI 444,JAPAN
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 1997年 / 23卷 / 06期
关键词
D O I
10.1016/S0886-3350(97)80245-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To find the conditions that prevent posterior capsule opacification through in vitro analysis of the relationship between intraocular lens (IOL) optic configuration and lens epithelial cell (LEG) migration. Setting: Division of Morphogenesis, Department of Developmental Biology, National Institute for Basic Biology, Okazaki, Japan. Methods: In a preliminary experiment, we measured the size of the capsular bag of rabbits at 8, 16, 20, and 26 weeks of age. The size of a 20-week-old capsular bag was the same size as the capsular bag in senescent Japanese eyes. We isolated the capsular bags in 20- and 8-week-old rabbits. The bags along with a biconvex (BC), convex-piano (CP), or no IOL (C) were cultured, and the eyes were divided into one of six groups (8W-C, 8W-BC, 8W-CP, 20W-C, 20W-BC and 20W-CP), each including six specimens. Results: Two specimens in the 8W-CP group completely blocked LEC migration at the optic edge. All specimens in the 20W-CP group and one in the 20W-BC group showed cell aggregation along the optic edge, None of the other specimens in the BC and C groups blocked migration or showed cell aggregation. Conclusions: In the rabbit-model study, the convex-piano lens was superior to the biconvex lens in inhibiting migration of LECs. A firm contact between the IOL and the posterior capsule blocked the migration.
引用
收藏
页码:866 / 872
页数:7
相关论文
共 50 条
  • [31] Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens
    Cleary, Georgia
    Spalton, David J.
    Hancox, Joanne
    Boyce, James
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 265 - 272
  • [32] THE LENS CAPSULE AND THE INTRAOCULAR-LENS - THE MOUSTACHE LENS
    BINKHORST, CD
    MODERNS TRENDS IN OPHTHALMOLOGY, 1989, 842 : 175 - 178
  • [33] Identification of Design Factors related to Intraocular Lens Fixation in the Lens Capsule
    Katayama, Shingo
    Nagasaka, Shinji
    Soda, Yasushi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [34] Inhibition of lens epithelial cell migration by an acrylic intraocular lens in vitro
    Kurosaka, D
    Obasawa, M
    Kurosaka, H
    Nakamura, K
    OPHTHALMIC RESEARCH, 2002, 34 (01) : 29 - 37
  • [35] EFFECT OF INTRAOCULAR-LENS SIZE ON POSTERIOR CAPSULE OPACIFICATION AFTER PHACOEMULSIFICATION
    MAMALIS, N
    CRANDALL, AS
    LINEBARGER, E
    SHEFFIELD, WK
    LEIDENIX, MJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (01): : 99 - 102
  • [36] Effect of in-the-bag intraocular lens fixation on the prevention of posterior capsule opacification
    Ram, J
    Pandey, SK
    Apple, DJ
    Werner, L
    Brar, GS
    Singh, R
    Chaudhary, KP
    Gupta, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07): : 1039 - 1046
  • [37] Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification
    Buehl, Wolf
    Menapace, Rupert
    Findl, Oliver
    Neumayer, Thomas
    Bolz, Matthias
    Prinz, Ana
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 913 - 919
  • [38] Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Sacu, S
    Kriechbaum, K
    Koeppl, C
    Wirtitsch, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05): : 954 - 961
  • [39] CYTOKERATIN IN LENS EPITHELIAL-CELLS AND ITS EFFECT ON ANTERIOR LENS CAPSULE OPACIFICATION
    BUDO, C
    MONTANUS, F
    GOFFINET, G
    GOOSSENS, G
    GAILL, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03): : 339 - 343
  • [40] Charges in lens epithelial cell migration for different edge design after silicone intraocular lens implantation
    Yanagawa, H
    Kobayakawa, S
    Katayama, Y
    Nagamine, K
    Miura, M
    Tochikubo, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U54 - U54