Effect of bar-code-assisted medication administration on medication administration errors and accuracy in multiple patient care areas

被引:74
|
作者
Helmons, Pieter J. [1 ]
Wargel, Lindsay N. [1 ]
Daniels, Charles E. [1 ,2 ]
机构
[1] Univ Calif San Diego, Med Ctr, Dept Pharm, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Skaggs Sch Pharm & Pharmaceut Sci, San Diego, CA 92103 USA
关键词
Codes; Drug administration; Errors; medication; Hospitals; Quality assurance; Technology; ADVERSE DRUG EVENTS; SAFETY; FREQUENCY; SYSTEM; IMPACT;
D O I
10.2146/ajhp080357
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose. The effect of a commercially available bar-code-assisted medication administration (BCMA) technology on six indicators of medication administration accuracy and nine types of medication administration errors in distinct patient care areas were studied. Methods. This prospective, before-and-after, observational study was conducted in two medical-surgical units, one medical intensive care unit (ICU), and one surgical ICU of a 386-bed academic teaching hospital. Nursing staff were observed administering medications one month before and three months after implementation of BCMA technology. Observations were conducted by two pharmacists and four pharmacy students on weekdays and weekends. Medication administration accuracy was measured using the accuracy indicator of the California Nursing Outcomes Coalition. Results. The majority of medication administrations occurred during the 9 a.m. medication round. After BCMA implementation in the medical-surgical units, improved adherence to patient identification policies was observed, but more distractions of the nursing staff occurred and the medications administered were less frequently explained to the patient. Although an increase in wrong-time errors was observed in the medical-surgical units, the total number of medication errors did not change. When wrong-time errors were excluded, the rate of medication errors decreased by 58%. In the ICUs, the charting of medication administration improved after BCMA implementation, but total medication errors and wrong-time errors did not change. Conclusion. Implementing BCMA technology decreased medication administration errors in medical-surgical units but not in ICUs when time errors were excluded. BCMA technology affected different types of medication administration errors in different patient care areas.
引用
收藏
页码:1202 / 1210
页数:9
相关论文
共 50 条
  • [31] Medication errors at the administration stage in an intensive care unit
    E. Tissot
    C. Cornette
    P. Demoly
    M. Jacquet
    F. Barale
    G. Capellier
    [J]. Intensive Care Medicine, 1999, 25 : 353 - 359
  • [32] Alert Types and Frequencies During Bar Code-Assisted Medication Administration A Systematic Review
    Sloss, Elizabeth A.
    Jones, Terry L.
    [J]. JOURNAL OF NURSING CARE QUALITY, 2020, 35 (03) : 265 - 269
  • [33] Medication administration errors after the introduction of Bar Code technology in a veterans affairs nursing home.
    Epure, J
    Tokushige, L
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (04) : S197 - S197
  • [34] Comparing the working time between Bar-Code Medication Administration system and traditional medication administration system: An observational study
    Tsai, Sing-ling
    Sun, Ying-Chou
    Taur, Fang-Meei
    [J]. INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2010, 79 (10) : 681 - 689
  • [35] Using Bar-Code Data to Streamline Medication Administration in the Neonatal Intensive Care Unit
    Angert, Robert
    Cregin, Regina
    Morgan-Joseph, Toshiba
    Cohen, Zahava
    [J]. PEDIATRICS, 2018, 142
  • [36] Using a bar-coded medication administration system to prevent medication errors in a community hospital network
    Sakowski, J
    Leonard, T
    Colburn, S
    Michaelsen, B
    Schiro, T
    Schneider, J
    Newman, JM
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (24) : 2619 - 2625
  • [37] Errors of oral medication administration in a patient with enteral feeding tube
    Emami, Shahram
    Hamishehkar, Hadi
    Mahmoodpoor, Ata
    Mashayekhi, Simin
    Asgharian, Parina
    [J]. JOURNAL OF RESEARCH IN PHARMACY PRACTICE, 2012, 1 (01) : 37 - 40
  • [38] Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds
    Miller, Daniel F.
    Fortier, Christopher R.
    Garrison, Kelli L.
    [J]. ANNALS OF PHARMACOTHERAPY, 2011, 45 (02) : 162 - 168
  • [39] Implementing a bar-code assisted medication administration system: Effects on the dispensing process and user perceptions
    Samaranayake, N. R.
    Cheung, S. T. D.
    Cheng, K.
    Lai, K.
    Chui, W. C. M.
    Cheung, B. M. Y.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2014, 83 (06) : 450 - 458
  • [40] Effect of barcode technology with electronic medication administration record on medication accuracy rates
    Seibert, Heather H.
    Maddox, Ray R.
    Flynn, Elizabeth A.
    Williams, Carolyn K.
    [J]. AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2014, 71 (03) : 209 - 218