Evaluation and optimization of a shock load de-icing method for transmission lines with combined ice failure criteria

被引:17
|
作者
Ji, Kunpeng [1 ]
Liu, Bin [1 ]
Cheng, Yongfeng [1 ]
Zhan, Xueping [1 ]
McClure, Ghyslaine [2 ]
机构
[1] China Elect Power Res Inst, Dept Power Transmiss & Transformat, 33 Nanbinhe Rd, Beijing 100055, Peoples R China
[2] McGill Univ, Dept Civil Engn & Appl Mech, 817 Sherbrooke St West, Montreal, PQ H3A 0C3, Canada
基金
加拿大自然科学与工程研究理事会; 北京市自然科学基金; 中国国家自然科学基金;
关键词
Dynamic response; Finite element analysis; Ice shedding; Mechanical de-icing; Overhead transmission lines; JUMP HEIGHT; CONDUCTORS;
D O I
10.1016/j.coldregions.2019.102818
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A mechanical de-icing process for overhead transmission lines using shock load is investigated numerically by finite element analysis, where a combination of three validated ice failure criteria is implemented, namely- the maximum bending strain criterion, the tensile detachment criterion and the shear detachment criterion. A total of 25 numerical scenarios are established and the ice shedding ratio and dynamic response of overhead lines are studied. The goal is to assess the relative importance of the leading parameters that affect the efficiency of the shock-load deicing method and the corresponding transient effects. The parameters under study include: the shock load characteristics (amplitude, time history and applied location along the span), the ice accretion characteristics (equivalent thickness and eccentricity ratio), and the line profile (height difference of span suspension points and adjacent spans). The study leads to suggestions to improve the de-icing efficiency of the shock-load method and reduce the adverse transient effects on the line components. The modeling approach used in this study provides a cost-effective tool and helpful reference for design, evaluation and optimization of a variety of mechanical de-icing methods, devices and procedures.
引用
收藏
页数:10
相关论文
共 45 条
  • [21] Elimination of Total Harmonic Distortion in Transmission Lines Using Adaptive Fuzzy Logic in De-Icing Process
    Foudeh, Husam
    Mokhtar, Ahmad Safawi
    2015 JIEEEC 9TH JORDANIAN INTERNATIONAL ELECTRICAL AND ELECTRONICS ENGINEERING CONFERENCE (JIEEEC), 2015,
  • [22] Design scheme of large-capacity fixed DC de-icing device for AC transmission lines
    Sun, Xu
    Wang, Mingxin
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (12): : 102 - 105
  • [23] Intelligent control and optimization of uninterrupted power serving de-icing technology for 110 kV power lines
    Guo, Ziqiang
    Zhang, Tianyi
    Jia, Laiqiang
    Liu, Ru
    Duan, Weiquan
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1910 - 1918
  • [24] ESTIMATION OF COMBINED ICE AND WIND LOAD ON OVERHEAD TRANSMISSION-LINES
    MCCOMBER, P
    MORIN, G
    MARTIN, R
    VAN, LV
    COLD REGIONS SCIENCE AND TECHNOLOGY, 1983, 6 (03) : 195 - 206
  • [25] An Online De-icing Method Based on Single-Phase Grounding Fault Current for Distribution Lines
    Yu, Kun
    Xie, Liwei
    Liu, Yixuan
    Zeng, Xiangjun
    Gu, Yingke
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3796 - 3800
  • [26] Ice Melting Capacity Evaluation of Applicable Materials of De-icing Fluid for High Speed Railway Rolling Stock
    Park, Gyoung-Won
    Lee, Jun-Ku
    Lee, Hong-Ki
    APPLIED CHEMISTRY FOR ENGINEERING, 2019, 30 (03): : 384 - 388
  • [27] Analysis and calculation of high-frequency excitation de-icing for transmission lines based on electromagnetic and thermal coupling field
    Yuan X.
    Zhou Y.
    Wang Y.
    Xiong Q.
    Wang X.
    Ma X.
    Dai Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (03): : 103 - 109
  • [28] De-icing EHV overhead transmission lines using electromagnetic forces generated by moderate short-circuit currents
    Landry, M
    Beauchemin, R
    Venne, A
    2000 IEEE ESMO - 2000 IEEE 9TH INTERNATIONAL CONFERENCE ON TRANSMISSION & DISTRIBUTION CONSTRUCTION, OPERATION & LIVE-LINE MAINTENANCE PROCEEDINGS, 2000, : 94 - 100
  • [29] A Risk Evaluation Method for Cascading Failure Considering Transmission Line Icing
    Feng, Xin
    Yang, Jun
    Luo, Chao
    Sun, Yuanzhang
    Liu, Mingsong
    Tang, Yong
    2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015,
  • [30] Aero-thermal optimization of in-flight electro-thermal ice protection systems in transient de-icing mode
    Pourbagian, Mandi
    Habashi, Wagdi G.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2015, 54 : 167 - 182