Experimental evaluation of re-entrainment from wet scrubber filtered containment venting systems

被引:5
|
作者
Lebel, L. S. [1 ]
Lessard, E. [1 ]
Batten, K. [1 ]
Clouthier, T. [1 ]
机构
[1] Canadian Nucl Labs, Chalk River, ON, Canada
关键词
Pool scrubbing experiments; Aerosol re-entrainment; Phase Doppler anemometry; Filtered containment venting systems; POOL ENTRAINMENT; SOURCE-TERM; MITIGATION; BEHAVIOR; BUBBLES;
D O I
10.1016/j.nucengdes.2020.110837
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Wet scrubber-based filtered containment venting systems (FCVSs) are commonly deployed at nuclear power plants, owing to the high degree of aerosol, iodine, and organic iodine retention that is possible through the pool scrubbing action that takes place during their operation. However, after a FCVS has been operating during a severe accident, the pool water will become extremely contaminated with previously-captured radionuclides, and the bubbling action of gases passing through the pool, could result in the re-entrainment of contaminated liquid droplets into the gas stream. This would produce a secondary source term during the late phases of an accident. As such, a set of experiments have been conducted in order to evaluate the aerosol re-entrainment rates and size distribution from a system prototypical of a pool-type FCVS. Entrainment rates were measured by tracking the carry-over of a NaCl tracer into a set of liquid traps, while the size of the re-entrained droplets was measured with a phase Doppler anemometer. The experiment employed a prototypical venturi nozzle and gas injection conditions to examine the influence of gas flow rate, liquid level, and pool water temperature. Entrainment factors between 5 x 10(-5) and 1 x 10(-3) were measured, and the water droplet count median diameters were between 3 and 13 mu m, and fairly wide particle size distributions, with mass mean diameters were on the order of 40-140 mu m. These experimental results help the assessment of the potential magnitude of the late phase source term hazards posed by the fission products retained in pool-type FCVS (secondary release), and the potential loading on the secondary dry filter stage (metal fiber filters) employed in FCVSs after the primary pool scrubbing stage. The secondary metal fiber filters should have a high efficiency in capturing water droplets produced through this mechanism, given the droplet's relatively large size.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Experimental and theoretical study of particulate re-entrainment from the combustion chamber walls of a diesel engine
    AbuQudais, M
    Kittelson, DB
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 1997, 211 (01) : 49 - 57
  • [22] Settling and re-entrainment of wax particles in near-gelling systems
    Kannan, Seetharaman Navaneetha
    Daraboina, Nagu
    Venkatesan, Rama
    Sarica, Cem
    AICHE JOURNAL, 2018, 64 (02) : 765 - 772
  • [23] Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test
    Kim, Sung Il
    Lee, Jae Bong
    Jung, Jae Hoon
    Ha, Kwang Soon
    Kim, Hwan Yeol
    Song, JinHo
    NUCLEAR ENGINEERING AND DESIGN, 2018, 326 : 344 - 353
  • [24] Experimental Investigation of Iodine Decontamination Performance of a Filtered Containment Venting System in ARIEL Facility
    Jung, Jaehoon
    Lee, Jae Bong
    Kim, Hwan Yeol
    26TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2017), 2017,
  • [25] RE-ENTRAINMENT OF BODY-TEMPERATURE IN EXPERIMENTAL SHIFT-WORK STUDIES
    KNAUTH, P
    RUTENFRANZ, J
    HERRMANN, G
    POEPPL, SJ
    ERGONOMICS, 1978, 21 (10) : 775 - 783
  • [26] When is flow re-entrainment important for the flushing time in coastal reef systems?
    Winter, G.
    Castelle, B.
    Lowe, R. J.
    Hansen, J. E.
    McCall, R.
    CONTINENTAL SHELF RESEARCH, 2020, 206
  • [27] Investigation of inclusion re-entrainment from the steel-slag interface
    Bouris, D
    Bergeles, G
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 1998, 29 (03): : 641 - 649
  • [28] Investigation of inclusion re-entrainment from the steel-slag interface
    D. Bouris
    G. Bergeles
    Metallurgical and Materials Transactions B, 1998, 29 : 641 - 649
  • [29] Re-entrainment and dispersion of exhausts from indoor radon reduction systems: Analysis of tracer gas data
    Henschel, DB
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (04): : 270 - 284
  • [30] Deposition and re-entrainment of model colloids in saturated consolidated porous media: Experimental study
    Canseco, V.
    Djehiche, A.
    Bertin, H.
    Omari, A.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 352 (1-3) : 5 - 11