Experimental evaluation of re-entrainment from wet scrubber filtered containment venting systems

被引:5
|
作者
Lebel, L. S. [1 ]
Lessard, E. [1 ]
Batten, K. [1 ]
Clouthier, T. [1 ]
机构
[1] Canadian Nucl Labs, Chalk River, ON, Canada
关键词
Pool scrubbing experiments; Aerosol re-entrainment; Phase Doppler anemometry; Filtered containment venting systems; POOL ENTRAINMENT; SOURCE-TERM; MITIGATION; BEHAVIOR; BUBBLES;
D O I
10.1016/j.nucengdes.2020.110837
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Wet scrubber-based filtered containment venting systems (FCVSs) are commonly deployed at nuclear power plants, owing to the high degree of aerosol, iodine, and organic iodine retention that is possible through the pool scrubbing action that takes place during their operation. However, after a FCVS has been operating during a severe accident, the pool water will become extremely contaminated with previously-captured radionuclides, and the bubbling action of gases passing through the pool, could result in the re-entrainment of contaminated liquid droplets into the gas stream. This would produce a secondary source term during the late phases of an accident. As such, a set of experiments have been conducted in order to evaluate the aerosol re-entrainment rates and size distribution from a system prototypical of a pool-type FCVS. Entrainment rates were measured by tracking the carry-over of a NaCl tracer into a set of liquid traps, while the size of the re-entrained droplets was measured with a phase Doppler anemometer. The experiment employed a prototypical venturi nozzle and gas injection conditions to examine the influence of gas flow rate, liquid level, and pool water temperature. Entrainment factors between 5 x 10(-5) and 1 x 10(-3) were measured, and the water droplet count median diameters were between 3 and 13 mu m, and fairly wide particle size distributions, with mass mean diameters were on the order of 40-140 mu m. These experimental results help the assessment of the potential magnitude of the late phase source term hazards posed by the fission products retained in pool-type FCVS (secondary release), and the potential loading on the secondary dry filter stage (metal fiber filters) employed in FCVSs after the primary pool scrubbing stage. The secondary metal fiber filters should have a high efficiency in capturing water droplets produced through this mechanism, given the droplet's relatively large size.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Overview of the experimental studies and numerical simulations on the filtered containment venting systems with wet scrubbers
    Dong, Shichang
    Yang, Jun
    ANNALS OF NUCLEAR ENERGY, 2019, 132 : 461 - 485
  • [2] Performance evaluation of venturi scrubber for the removal of iodine in filtered containment venting system
    Bal, Manisha
    Reddy, Thamatam Tejaswini
    Melkap, B. C.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 138 : 158 - 167
  • [3] SCALING ANALYSIS OF SCRUBBER POOL AND CYCLONE FOR FILTERED CONTAINMENT VENTING SYSTEM TESTING
    Revankar, Shripad T.
    Song, JinHo
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 7, 2017,
  • [4] Re-entrainment of particles from powder structures: experimental investigations
    Grzybowski, Krzysztof
    Gradon, Leon
    ADVANCED POWDER TECHNOLOGY, 2007, 18 (04) : 427 - 439
  • [5] ANALYZING DROPLET SIZE DISTRIBUTIONS INSIDE A SELF-PRIMING VENTURI SCRUBBER FOR FILTERED CONTAINMENT VENTING SYSTEMS
    Papadopoulos, P.
    Lind, T.
    Prasser, H. -M.
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 6B, 2018,
  • [6] Concept for a cyclonic spray scrubber as a fission product removal system for filtered containment venting
    Lebel, Luke S.
    Piro, Markus H.
    MacCoy, Reilly
    Clouthier, Anthony
    Chin, Yu-Shan
    NUCLEAR ENGINEERING AND DESIGN, 2016, 297 : 60 - 71
  • [7] Prediction of pressure drop in a Venturi scrubber: Effect of liquid film and re-entrainment
    Rahimi, A
    Taheri, M
    Fathikalajahi, J
    CHEMICAL ENGINEERING COMMUNICATIONS, 2004, 191 (03) : 315 - 334
  • [8] Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation
    Dong, Shichang
    Zhou, Xiafeng
    Yang, Jun
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (07) : 1396 - 1408
  • [9] Experimental Research on Mechanism of Aerosol Re-entrainment Behavior in Containment under Severe Accident Condition
    Hu Z.
    Chen L.
    Ji S.
    Wei Y.
    Shi X.
    Zheng G.
    Hedongli Gongcheng/Nuclear Power Engineering, 2023, 44 (04): : 253 - 258
  • [10] RE-ENTRAINMENT OF PARTICLES FROM A PLANE SURFACE
    CORN, M
    STEIN, F
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1965, 26 (04): : 325 - &