Migration of an intrauterine contraceptive device into the sigmoid colon

被引:0
|
作者
Al-Mukhtar, Rola S. [1 ]
Al-Ali, Jaber A. [2 ]
Amin, Maher M. [1 ]
Al-Sumait, Basel M. [1 ]
机构
[1] Kuwait Univ, Dept Surg, Fac Med, Mubarak Al Kabeer Hosp,Minist Hlth, Surah 45704, Kuwait
[2] Kuwait Univ, Dept Gastroenterol, Fac Med, Mubarak Al Kabeer Hosp,Minist Hlth, Surah 45704, Kuwait
关键词
PERFORATION; RETRIEVAL; REMOVAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present a case of migrating copper-T intrauterine contraceptive device (IUCD) into the bowel wall at the recto-sigmoid junction, and the colonoscopic retrieval of the device. This case introduces the possibility of safe rectal retrieval of migrating IUCD implanted into the bowel wall.
引用
收藏
页码:561 / 563
页数:3
相关论文
共 50 条
  • [41] Sigmoid colocolic fistula caused by intrauterine device migration: A case report
    Weerasekera A.
    Wijesinghe P.
    Nugaduwa N.
    [J]. Journal of Medical Case Reports, 8 (1)
  • [42] INTRAUTERINE CONTRACEPTIVE DEVICE - CONTRACEPTIVE OR ABORTIFACIENT
    KORT, H
    VANDERWALT, LA
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1978, 53 (21): : 864 - 866
  • [43] PERFORATION OF THE UTERUS AND COLON BY COPPER-T INTRAUTERINE CONTRACEPTIVE DEVICE
    BOLAJI, II
    SARIDOGAN, E
    LAMMERS, G
    FIELDMAN, N
    DJAHANBAKHCH, O
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1995, 48 (02) : 231 - 232
  • [44] An Unusual, Delayed Presentation of a Migrated Intrauterine Contraceptive Device Into the Rectosigmoid Colon
    Toh, Wuen Lynn
    Lim, Whui Whui
    Tan, Wei Keat Andy
    Lim, Shau Khng Jason
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [45] Sigmoid penetration by an intrauterine device
    Baakdah, H
    Asswad, AF
    Tulandi, T
    [J]. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2005, 12 (05) : 384 - 384
  • [46] Transmigration of an intrauterine device into sigmoid colon-surgical management: A case report
    Kaleem, Ahmad
    Zaman, Balakh Sher
    Nasir, Muneeba
    Hassan, Azhar
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (11) : 1716 - 1718
  • [47] Sigmoid colon translocation of an intrauterine device misdiagnosed as a colonic polyp A case report
    Zhou, Xin-Xin
    Yu, Mo-Sang
    Gu, Meng-Li
    Zhong, Wei-Xiang
    Wu, Hong-Ru
    Ji, Feng
    Pan, Hang-Hai
    [J]. MEDICINE, 2018, 97 (06)
  • [48] Far migration of an intrauterine contraceptive device from the uterus to the small bowel
    Carroll, Alexandria
    Paradise, Courtney
    Schuemann, Katie
    Schellhammer, Shannon Scott
    Carlan, Steve J.
    [J]. CLINICAL CASE REPORTS, 2022, 10 (03):
  • [49] Migration of an Intrauterine Contraceptive Device during the Course of Pregnancy: A Case Report
    Glass, Tracy
    Baker, Teresa
    Kauffman, Robert P.
    [J]. JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2009, 16 (01) : 81 - 83
  • [50] Removal of Complete Spontaneous Migration of an Intrauterine Contraceptive Device to the Bladder by Cystoscopy
    Saputra, Akbar Novan Dwi
    Rahman, Muhammad Nurhadi
    Widyasari, Anis
    [J]. CASE REPORTS IN OBSTETRICS AND GYNECOLOGY, 2024, 2024