Numerical simulation of non-Newtonian models effect on hemodynamic factors of pulsatile blood flow in elastic stenosed artery

被引:47
|
作者
Jahangiri, Mehdi [1 ]
Saghafian, Mohsen [1 ]
Sadeghi, Mahmood Reza [2 ]
机构
[1] Isfahan Univ Technol, Dept Mech Engn, Esfahan 8415683111, Iran
[2] Univ Isfahan, Dept Biomed Engn, Esfahan 8174673441, Iran
关键词
Adina; Consecutive stenosis; Fluid-solid interaction; Hemodynamic; Reverse flow; Stenosis; WALL SHEAR-STRESS; COMPUTATIONAL FLUID-DYNAMICS; LEFT CORONARY-ARTERY; INTRACRANIAL ANEURYSMS; MIRROR ANEURYSMS; PLAQUE LOCATION; PARAMETERS; BIFURCATION; VESSEL; VISCOSITY;
D O I
10.1007/s12206-017-0153-x
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Atherosclerosis develops due to different hemodynamic factors, among which time-averaged Wall shear stress (mean WSS) and Oscillatory shear index (OSI) are two of the most important. These two factors not only depend on flow geometry, but are also influenced by rheological characteristics of blood. Since analytical solutions are limited to simple problems and since experimental tests are costly and time consuming, CFD solutions been prominently and effectively used to solve such problems. We conducted a numerical study via ADINA 8.8 software on the non-Newtonian pulsatile flow of blood through an elastic blood artery with single and consecutive stenosis. The studied stenosis cross sectional area was 70 % that of the unstenosed artery. The single stenosis results were compared with the consecutive stenosis results. The five non-Newtonian flow models, the Carreau model, the Carreau-Yasuda model, the modified Casson model, the power-law model, and the generalized power-law model, were used to model the non-Newtonian blood flow. The obtained results showed that increasing the number of stenoses would lead to reduced length of the oscillatory area after the first stenosis, thus forming another oscillatory area with a larger length after the second stenosis. Thus, a consecutive stenosis would develop a larger disease prone area. Upon examining the mean WSS and OSI, we found that, as compared with the other models, the modified Casson model and the power-law model produced predictions for the most extent of damage to endothelial cells and the most disease prone areas, respectively.
引用
收藏
页码:1003 / 1013
页数:11
相关论文
共 50 条
  • [1] Numerical simulation of non-Newtonian models effect on hemodynamic factors of pulsatile blood flow in elastic stenosed artery
    Mehdi Jahangiri
    Mohsen Saghafian
    Mahmood Reza Sadeghi
    [J]. Journal of Mechanical Science and Technology, 2017, 31 : 1003 - 1013
  • [2] The impact of uniform magnetic field on the pulsatile non-Newtonian blood flow in an elastic stenosed artery
    Sadeghi, Mahmood Reza
    Jahangiri, Mehdi
    Saghafian, Mohsen
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (11)
  • [3] The impact of uniform magnetic field on the pulsatile non-Newtonian blood flow in an elastic stenosed artery
    Mahmood Reza Sadeghi
    Mehdi Jahangiri
    Mohsen Saghafian
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [4] NUMERICAL STUDY OF THE NON-NEWTONIAN BLOOD FLOW IN A STENOSED ARTERY USING TWO RHEOLOGICAL MODELS
    Achab, Louiza
    Mahfoud, Mohamed
    Benhadid, Salah
    [J]. THERMAL SCIENCE, 2016, 20 (02): : 449 - 460
  • [5] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Y. Fan X. Deng School of Biological Science and Medical Engineering
    [J]. Acta Mechanica Sinica, 2009, (02) : 249 - 255
  • [6] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Yubo Fan
    Wentao Jiang
    Yuanwen Zou
    Jinchuan Li
    Junkai Chen
    Xiaoyan Deng
    [J]. Acta Mechanica Sinica, 2009, 25 : 249 - 255
  • [7] Numerical investigation of unsteady pulsatile Newtonian/non-Newtonian blood flow through curved stenosed arteries
    Lakzian, E.
    Akbarzadeh, P.
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 525 - 540
  • [8] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Fan, Yubo
    Jiang, Wentao
    Zou, Yuanwen
    Li, Jinchuan
    Chen, Junkai
    Deng, Xiaoyan
    [J]. ACTA MECHANICA SINICA, 2009, 25 (02) : 249 - 255
  • [9] Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis
    Tian, Fang-Bao
    Zhu, Luoding
    Fok, Pak-Wing
    Lu, Xi-Yun
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) : 1098 - 1113
  • [10] THE ANALYSIS OF THE FLOW OF BLOOD IN A STENOSED ARTERY THROUGH SIMULATION: A COMPARISON AMONG VARIOUS NON-NEWTONIAN MODELS
    Narayan, S. shankar
    Bhattacharjee, Anuradha
    Saha, Sunanda
    Puneeth, Venkatesh
    Singhal, Abhinav
    Abdullaeva, Barno Sayfutdinovna
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2024,