Experimental studies on the behaviour of headed shear studs for composite beams in fire

被引:7
|
作者
Lim, Ohk Kun [1 ,2 ]
Choi, Sengkwan [2 ]
Kang, Sungwook [3 ]
Kwon, Minjae [3 ]
Choi, J. Yoon [3 ]
机构
[1] Korea Fire Inst, R&D Lab, 331 Jisam Ro, Gyeonggi Do 17088, South Korea
[2] Ulster Univ, Sch Built Environm, Newtownabbey BT37 0QB, North Ireland
[3] Korea Conform Labs, Fire Safety Ctr, 73 Yangcheong 3 Gil, Cheongju 28115, South Korea
来源
STEEL AND COMPOSITE STRUCTURES | 2019年 / 32卷 / 06期
关键词
composite beam; headed shear stud; push-out test; transverse deck; fire; CONNECTORS; PERFORMANCE;
D O I
10.12989/scs.2019.32.6.743
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.
引用
收藏
页码:743 / 752
页数:10
相关论文
共 50 条
  • [31] Studies on the load-carrying behaviour of steel-to-concrete joints with headed studs for normal and shear loads
    Ruopp, Jakob
    Kuhlmann, Ulrike
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2023, 16 (04): : 243 - 255
  • [32] Strength of headed stud shear connection in composite beams
    Ernst, S.
    Bridge, R.
    Wheeler, A.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2006, 7 (02) : 111 - 121
  • [33] Experimental Investigation of Composite Beams with Shear Connections Subjected to Fire Loading
    Selden, Kristi L.
    Fischer, Erica C.
    Varma, Amit H.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (02)
  • [34] Experiment-Based Fatigue Behaviors and Damage Detection Study of Headed Shear Studs in Steel-Concrete Composite Beams
    Xu, Jun
    Sun, Huahuai
    Chen, Weizhen
    Guo, Xuan
    APPLIED SCIENCES-BASEL, 2021, 11 (18):
  • [35] Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures
    Mirza, O.
    Uy, B.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (03) : 662 - 674
  • [36] Ultimate shear strength of inclined headed studs
    Sadasue K.
    Ogomori H.
    Journal of Structural and Construction Engineering, 2020, 85 (769): : 403 - 413
  • [37] Experimental study on the hybrid shear connection using headed studs and steel plates
    Baek, Jang-Woon
    Yang, Hyeon-Keun
    Park, Hong-Gun
    Eom, Tae-Sung
    Hwang, Hyeon-Jong
    STEEL AND COMPOSITE STRUCTURES, 2020, 37 (06): : 649 - 662
  • [38] Size effect on the shear capacity of headed studs
    Donmez, Ahmet Abdullah
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (04) : 815 - 826
  • [39] Performance of Experimental and Theoretical Analysis on Shear Short Headed Studs Embedded in UHPC
    Li M.
    Shao X.-D.
    Cao J.-H.
    He G.
    Chen Y.-B.
    Zhao X.-D.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2021, 34 (08): : 191 - 204
  • [40] Shear behavior and design of headed studs embedded in steel-UHPC composite structures
    Lai, Zhichao
    Weng, Xiangyu
    Yang, Xiaoqiang
    Zhao, Haoran
    STRUCTURES, 2024, 59