Experimental studies on the behaviour of headed shear studs for composite beams in fire

被引:7
|
作者
Lim, Ohk Kun [1 ,2 ]
Choi, Sengkwan [2 ]
Kang, Sungwook [3 ]
Kwon, Minjae [3 ]
Choi, J. Yoon [3 ]
机构
[1] Korea Fire Inst, R&D Lab, 331 Jisam Ro, Gyeonggi Do 17088, South Korea
[2] Ulster Univ, Sch Built Environm, Newtownabbey BT37 0QB, North Ireland
[3] Korea Conform Labs, Fire Safety Ctr, 73 Yangcheong 3 Gil, Cheongju 28115, South Korea
来源
STEEL AND COMPOSITE STRUCTURES | 2019年 / 32卷 / 06期
关键词
composite beam; headed shear stud; push-out test; transverse deck; fire; CONNECTORS; PERFORMANCE;
D O I
10.12989/scs.2019.32.6.743
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.
引用
收藏
页码:743 / 752
页数:10
相关论文
共 50 条
  • [1] Behaviour of demountable steel-concrete composite beams with bolts and headed studs
    Jakovljević, Isidora
    Spremić, Milan
    Fric, Nenad
    Marković, Zlatko
    [J]. ce/papers, 2023, 6 (3-4) : 84 - 89
  • [2] Seismic behaviour of double skin composite shear walls with overlapped headed studs
    Yan, Jia-Bao
    Li, Zhong-Xian
    Wang, Tao
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 191 : 590 - 607
  • [3] EXPERIMENTAL STUDIES ON THE BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL CONCRETE BEAMS UNDER ELEVATED TEMPERATURES
    Mirza, O.
    Uy, B.
    Krezo, S.
    [J]. Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 467 - 473
  • [4] New investigations on the fatigue behaviour of headed shear studs
    Hanswille, Gerhard
    Porsch, Markus
    Üstündag, Cenk
    [J]. Stahlbau, 2006, 75 (04) : 303 - 316
  • [5] SHEAR BEHAVIOUR OF DEMOUNTABLE CONNECTIONS WITH BOLTS AND HEADED STUDS
    Jakovljevic, Isidora
    Spremic, Milan
    Markovic, Zlatko
    [J]. ADVANCED STEEL CONSTRUCTION, 2023, 19 (04): : 341 - 352
  • [6] Fire performance of headed shear studs in profiled steel sheeting
    Lim, Ohk Kun
    Choi, Sengkwan
    Kang, Sungwook
    Kwon, Minjae
    Choi, J. Yoon
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 164
  • [7] Behaviour of Headed Shear Stud in Composite Beams with Profiled Metal Decking
    Qureshi, Jawed
    Lam, Dennis
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (09) : 1547 - 1558
  • [8] Residual Post-fire Strength of Shear Studs in Composite Beams with Solid Slabs
    Erfan Maliji
    Hossein Yousefpour
    [J]. Fire Technology, 2024, 60 : 369 - 400
  • [9] Contribution of headed studs to the composite behavior of the partially encased beams
    De Nardin, Silvana
    El Debs, Ana Lucia H. de C.
    [J]. REM-REVISTA ESCOLA DE MINAS, 2008, 61 (02) : 239 - 247
  • [10] Residual Post-fire Strength of Shear Studs in Composite Beams with Solid Slabs
    Maliji, Erfan
    Yousefpour, Hossein
    [J]. FIRE TECHNOLOGY, 2024, 60 (01) : 369 - 400