Water Tree Detection in Medium Voltage XLPE Cables

被引:0
|
作者
McDermid, W. [1 ]
Partyka, M. [1 ]
Black, T. [1 ]
机构
[1] Manitoba Hydro, High Voltage Test Facil, Winnipeg, MB, Canada
关键词
medium voltage XLPE cables; water trees; DIAGNOSTIC METHOD;
D O I
10.1109/eic43217.2019.9046547
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
During the period of 1993-1995 Manitoba Hydro investigated the claim by a service provider that water trees could be detected and located in service aged medium voltage XLPE cables by means of time domain reflectometry (TDR) following conditioning of the cable dielectric with direct voltage. In order to avoid subsequent short time in-service failures, it was necessary to limit the conditioning voltage to 0.5 per-unit. With this restriction, no conditioning related surge impedance anomalies were found in cable that subsequently was determined as containing substantial vented water trees. However, it was established that the measurement of leakage current at 0.5 per-unit negative polarity direct voltage did correlate with the magnitude of subsequent 0.1 Hz breakdown voltage. Beginning in 2014 Manitoba Hydro has been assessing service aged medium voltage XLPE cables using Tangent Delta measurements at 0.1 Hz voltages in accordance with IEEE Std 400.2. However, the notion that water tress can be detected and located as a result of conditioning with direct voltage is still of interest as is indicated by publications that have appeared in the literature in recent years, but the related conditioning utilizes direct voltages in excess of 0.5 per-unit.
引用
收藏
页码:217 / 220
页数:4
相关论文
共 50 条
  • [31] Problems of Increase in Operating Reliability and Ecological Compatibility of Medium Voltage XLPE Cables
    Lavrov, J. A.
    Dubrovsky, D. V.
    IFOST: 2007 INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGY, 2007, : 657 - +
  • [32] Pulse Response Measurement for Locating Water Tree Degradation in XLPE Cables
    Hiei, Susumu
    Hozumi, Naohiro
    Kurihara, Takashi
    Okamoto, Tatsuki
    Uchida, Katsumi
    Tsuji, Taizo
    ELECTRICAL ENGINEERING IN JAPAN, 2012, 180 (03) : 18 - 24
  • [33] THE VOLTAGE BREAKDOWN CHARACTERISTICS OF MINIATURE XLPE CABLES CONTAINING WATER TREES
    BULINSKI, A
    DENSLEY, RJ
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1981, 16 (04): : 319 - 326
  • [34] Design of XLPE cables and soundness confirmation methods to extra high voltage XLPE cables
    Katakai, S
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1411 - 1415
  • [35] A Possible Water Tree Initiation Mechanism for Service-aged XLPE Cables: Conversion of Electrical Tree to Water Tree
    Zhou, Kai
    Huang, Ming
    Tao, Wenbiao
    He, Min
    Yang, Mingliang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1854 - 1861
  • [36] Detection of water trees in medium voltage cables by RVM, without reference measurements
    Alijagic-Jonuz, B
    Morshuis, PHF
    van Breen, HJ
    Smit, JJ
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 504 - 507
  • [37] The role of cations in water tree growth in technical grade XLPE insulated cables
    Malik, N. H.
    Qureshi, M. I.
    Al-Arainy, A.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 127 - +
  • [38] EFFECTS OF FREQUENCY AND TEMPERATURE ON WATER TREE DEGRADATION OF MINIATURE XLPE CABLES.
    Bulinski, A.T.
    Bamji, S.S.
    Densley, R.J.
    IEEE transactions on electrical insulation, 1986, EI-21 (04): : 645 - 650
  • [39] Research on Treeing Retardant Performance and Test Protocol of Medium Voltage XLPE Power Cables
    Xu Lin-hua
    Yang Li-ming
    Yan Meng-kun Yan
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 338 - 341
  • [40] On-Site Diagnostic Tests on Medium Voltage, XLPE-Insulated Power Cables
    Abou Dakka, Mahmoud
    Bulinski, Alexander
    Bamji, Soli
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3019 - 3024