Mesoporous CeO2 nanoparticles modified Glassy carbon electrode for individual and simultaneous determination of Cu(II) and Hg(II): Application to environmental samples

被引:21
|
作者
Adarakatti, Prashanth Shivappa [1 ]
Gangaiah, Vijayakumar [2 ]
Siddaramanna, Ashoka [3 ]
机构
[1] Indian Inst Sci, Solid State & Struct Chem Unit, Bengaluru, India
[2] Bangalore Univ, Cent Coll Campus, Dept Chem, Bengaluru, India
[3] Dayananda Sagar Univ, Sch Engn, Kudlu Gate, Bengaluru, India
关键词
CeO2; nanoparticles; Modified electrode; Anodic stripping voltammetry; Quantification; SIMULTANEOUS ELECTROCHEMICAL DETECTION; PASTE ELECTRODE; SENSITIVE DETERMINATION; COPPER; LEAD; SENSOR; MERCURY; PERFORMANCE; IONS; ZINC;
D O I
10.1016/j.mssp.2018.05.010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An electrochemical sensor based on the use of CeO2 nanoparticles modified glassy carbon electrode (CeO2/GCE) was prepared and applied for determination of Cu(II) and Hg(II) individually and simultaneously. The differential pulse anodic stripping voltammetry (DPASV) results indicates that the CeO2 NPs based sensor exhibits good electroanalytical performance with two well-resolved voltammetric stripping peaks for Cu(II) and Hg(II). The proposed CeO2 NPs based sensor shows a wide linear range from 10 to 350 mu g/L and a lower detection limit (3o) 2.9 for Cu(II) and 3.3 mu g/L for Hg(II) under optimized conditions. The developed sensor was successfully applied for the quantification of Cu(II) and Hg(II) in real sample matrices, and satisfactory results were obtained.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [31] Anodic stripping voltammetric determination of traces of Pb(II) and Cd(II) using a glassy carbon electrode modified with bismuth nanoparticles
    Die Yang
    Liang Wang
    Zuliang Chen
    Mallavarapu Megharaj
    Ravi Naidu
    Microchimica Acta, 2014, 181 : 1199 - 1206
  • [32] A novel Cu(II) detection assay via modified glassy carbon electrode
    Akyildirim, Onur
    Yuksek, Haydar
    Gursoy Kol, Ozlem
    Manap, Sevda
    Beytur, Murat
    Yola, Mehmet Lutfi
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2018, 24 (07): : 1284 - 1286
  • [33] Simultaneous detection of Cu(II) and Pb(II) in the Danube river using a bismuth film modified glassy carbon rotating disk electrode
    Bounegru, Alexandra Virginia
    Georgescu, Lucian P.
    Iticescu, Catalina
    Apetrei, Constantin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2025, 979
  • [34] Ordered Mesoporous Carbon and Thiolated Polyaniline Modified Electrode for Simultaneous Determination of Cadmium(II) and Lead(II) by Anodic Stripping Voltammetry
    Tang, Lin
    Chen, Jun
    Zeng, Guangming
    Zhu, Yuan
    Zhang, Yi
    Zhou, Yaoyu
    Xie, Xia
    Yang, Guide
    Zhang, Sheng
    ELECTROANALYSIS, 2014, 26 (10) : 2283 - 2291
  • [35] A new sensor based on In doped CeO2 nanoparticles modified glassy carbon paste electrode for sensitive determination of uric acid in biological fluids
    Temerk, Yassien
    Ibrahim, Hossieny
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 868 - 877
  • [36] Simultaneous Determination of Hg(II), Cd(II), Pb(II) and Zn(II) by Anodic Stripping Voltammetry using Modified Carbon Paste Ionic Liquid Electrode
    Faridan, Ashkan
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (06): : 810 - 827
  • [37] Simultaneous electrochemical determination of uric acid and ascorbic acid on a glassy carbon electrode modified with cobalt(II) tetrakisphenylporphyrin
    Li, CX
    Zeng, YL
    Liu, YJ
    Tang, CR
    ANALYTICAL SCIENCES, 2006, 22 (03) : 393 - 397
  • [38] Preconcentration and voltammetric determination of mercury(II) at a chemically modified glassy carbon electrode
    Sousa, MDB
    Bertazzoli, R
    ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1258 - 1261
  • [39] Simultaneous Electrochemical Determination of Uric Acid and Ascorbic Acid on a Glassy Carbon Electrode Modified with Cobalt(II) Tetrakisphenylporphyrin
    Chun-Xiang Li
    Yun-Long Zeng
    Ying-Ju Liu
    Chun-Rang Tang
    Analytical Sciences, 2006, 22 : 393 - 397
  • [40] Study on determination of lead (II) using pyrogallolarene modified glassy carbon electrode
    Sun, Wen-Bin
    Wang, Xiao-Ling
    Wu, Fang-Hui
    Yejin Fenxi/Metallurgical Analysis, 2008, 28 (05): : 10 - 13