The fixation of the cemented femoral component - Effects of stem stiffness, cement thickness and roughness of the cement-bone surface

被引:108
|
作者
Ramaniraka, NA [1 ]
Rakotomanana, LR [1 ]
Leyvraz, PF [1 ]
机构
[1] Orthoped Hosp, CH-1005 Lausanne, Switzerland
来源
关键词
D O I
10.1302/0301-620X.82B2.9613
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [41] The influence of bone cement type on production of fretting wear on the femoral stem surface: A preliminary study
    Zhang, H. Y.
    Blunt, L. A.
    Jiang, X. Q.
    Fleming, L. T.
    Barrans, S. M.
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 666 - 672
  • [42] Effects of the absorber, thickness and surface roughness on the electromagnetic wave absorption characteristics of magnesium phosphate cement
    Liu, Xiongfei
    Wang, Nan
    Wang, Zhuang
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 344
  • [43] The contribution of the micropores in bone cement surface to generation of femoral stem wear in total hip replacement
    Zhang, Hongyu
    Brown, Leigh
    Blunt, Liam
    Jiang, Xiangqian
    Barrans, Simon
    TRIBOLOGY INTERNATIONAL, 2011, 44 (11) : 1476 - 1482
  • [44] Fatigue debonding of the roughened stem-cement interface: Effects of surface roughness and stem heating conditions
    Damron, LA
    Kim, DG
    Mann, KA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 181 - 188
  • [45] Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement
    Harvey, EJ
    Bobyn, JD
    Tanzer, M
    Stackpool, GJ
    Krygier, JJ
    Hacking, SA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 93 - 107
  • [46] PULMONARY EMBOLIZATION OF FEMORAL INTRAMEDULLARY CONTENTS DURING FIXATION OF PROSTHESIS WITH BONE CEMENT
    KALLOS, T
    ENIS, JE
    GOLD, MI
    GOLLAN, F
    DAVIS, JH
    SARMIENT.A
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (04): : 850 - 850
  • [47] THE INFLUENCE OF STEM SURFACE IN MICROMOBILITY AND CEMENT BONE STRESSES
    Ramos, A.
    Relvas, C.
    Completo, A.
    Simoes, J. A.
    COMPUTATIONAL METHODS FOR COUPLED PROBLEMS IN SCIENCE AND ENGINEERING IV, 2011, : 1251 - 1260
  • [48] Microstructure study on bone cement mantle polymerised in an idealized specimen of cemented hip implants with different initial temperature of the stem and bone cement
    Madrala, A.
    Nuño, N.
    Bureau, M.N.
    Computer Methods in Biomechanics and Biomedical Engineering, 2007, 10 (SUPPL. 1) : 67 - 68
  • [49] The effect of cement mantle thickness on strain energy density distribution and prediction of bone density changes around cemented acetabular component
    Sanjay, Devismita
    Mondal, Subrata
    Bhutani, Richa
    Ghosh, Rajesh
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (09) : 912 - 921