The fixation of the cemented femoral component - Effects of stem stiffness, cement thickness and roughness of the cement-bone surface

被引:108
|
作者
Ramaniraka, NA [1 ]
Rakotomanana, LR [1 ]
Leyvraz, PF [1 ]
机构
[1] Orthoped Hosp, CH-1005 Lausanne, Switzerland
来源
关键词
D O I
10.1302/0301-620X.82B2.9613
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] Novel methods to study functional loading micromechanics at the stem-cement and cement-bone interface in cemented femoral hip replacements
    Race, A.
    Miller, M. A.
    Mann, K. A.
    JOURNAL OF BIOMECHANICS, 2010, 43 (04) : 788 - 791
  • [2] Application of an Amphiphilic bonder in a goat model to increase the femoral cement-bone adhesion in cemented hip arthroplasty
    Mueller-Rath, R.
    Wirtz, D.
    Andereya, S.
    Gravius, S.
    Hermanns-Sachweh, B.
    Marx, R.
    Mumme, T.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 (04): : 476 - 482
  • [3] FEMORAL STEM FIXATION - THE CASE FOR CEMENT
    WELCH, RB
    MCGANN, WA
    RASMUSSEN, L
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (261) : 134 - 139
  • [4] The Influence of Cement Morphology Parameters on the Strength of the Cement-Bone Interface in Tibial Tray Fixation
    Nagel, Katrin
    Bishop, Nicholas E.
    Schlegel, Ulf J.
    Pueschel, Klaus
    Morlock, Michael M.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 563 - +
  • [5] Similitude of cement-bone micromechanics in cemented rat and human knee replacement
    Mann, Kenneth A.
    Miller, Mark A.
    Tatusko, Megan E.
    Oest, Megan E.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (07) : 1529 - 1537
  • [6] The mechanical effects of different levels of cement penetration at the cement-bone interface
    Waanders, Daan
    Janssen, Dennis
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF BIOMECHANICS, 2010, 43 (06) : 1167 - 1175
  • [7] THE EFFECTS OF FEMORAL CANAL GEOMETRIES, STEM SHAPES, CEMENT THICKNESS, AND STEM MATERIALS ON THE CHOICE OF FEMORAL IMPLANT IN CEMENTED TOTAL HIP REPLACEMENT
    Lai, Yu-Shu
    Wei, Hung-Wen
    Chang, Ting-Kuo
    Cheng, Cheng-Kung
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2009, 32 (03) : 333 - 341
  • [8] Residual stress effects on fracture energies of cement-bone and cement-implant interfaces
    Zor, M
    Küçük, M
    Aksoy, S
    BIOMATERIALS, 2002, 23 (07) : 1595 - 1601
  • [9] STRESS TRANSFER AT THE FEMORAL BONE BONE-CEMENT INTERFACE AS A FUNCTION OF THE CEMENT THICKNESS
    JANSSON, V
    HEIMKES, B
    ZIMMER, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1993, 112 (02) : 65 - 68
  • [10] Risk factors for a radiolucent line around the acetabular component with an interface bioactive bone cement technique after primary cemented total hip arthroplasty PROGNOSTIC FACTORS FOR A RADIOLUCENT LINE AND IMPROVEMENT OF THE CEMENT-BONE INTERFACE AROUND CEMENTED ACETABULAR COMPONENT WITH AN INTERFACE BIOACTIVE BONE CEMENT TECHNIQUE
    Miyamoto, S.
    Iida, S.
    Suzuki, C.
    Nakatani, T.
    Kawarai, Y.
    Nakamura, J.
    Orita, S.
    Ohtori, S.
    BONE & JOINT OPEN, 2021, 2 (05): : 278 - 292