Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise

被引:21
|
作者
Contreras-Briceno, Felipe [1 ,2 ]
Espinosa-Ramirez, Maximiliano [1 ]
Hevia, Gonzalo [1 ]
Llambias, Diego [1 ]
Carrasco, Miguel [1 ]
Cerda, Francisco [1 ]
Lopez-Fuenzalida, Antonio [1 ]
Garcia, Patricio [1 ]
Gabrielli, Luigi [3 ]
Viscor, Gines [2 ]
机构
[1] Pontificia Univ Catolica Chile, Lab Exercise Physiol, Dept Hlth Sci, Fac Med, Ave Vicuna Mackenna 4860, Santiago, Chile
[2] Univ Barcelona, Dept Cell Biol Physiol & Immunol, Fac Biol, Physiol Sect, Barcelona, Spain
[3] Pontificia Univ Catolica Chile, Adv Ctr Chron Dis ACCDiS, Sch Med, Santiago, Chile
关键词
Muscle oxygenation; exercise; respiration; near-infrared spectroscopy; NEAR-INFRARED SPECTROSCOPY; BLOOD-FLOW LIMITATION; INCREMENTAL EXERCISE; COST; LOCOMOTOR; DEOXYGENATION; AVAILABILITY; SCIENCE; WORK;
D O I
10.1080/02640414.2019.1653422
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study assessed the intra-individual reliability of oxygen saturation in intercostal muscles (SmO2-m.intercostales) during an incremental maximal treadmill exercise by using portable NIRS devices in a test-retest study. Fifteen marathon runners (age, 24.9 +/- 2.0 years; body mass index, 21.6 +/- 2.3 kg center dot m(-2); V?O-2-peak, 63.7 +/- 5.9 mL center dot kg(-1)center dot min(-1)) were tested on two separate days, with a 7-day interval between the two measurements. Oxygen consumption (V?O-2) was assessed using the breath-by-breath method during the V?O-2-test, while SmO2 was determined using a portable commercial device, based in the near-infrared spectroscopy (NIRS) principle. The minute ventilation (VE), respiratory rate (RR), and tidal volume (Vt) were also monitored during the cardiopulmonary exercise test. For the SmO2-m.intercostales, the intraclass correlation coefficient (ICC) at rest, first (VT1) and second ventilatory (VT2) thresholds, and maximal stages were 0.90, 0.84, 0.92, and 0.93, respectively; the confidence intervals ranged from -10.8% - +9.5% to -15.3% - +12.5%. The reliability was good at low intensity (rest and VT1) and excellent at high intensity (VT2 and max). The Spearman correlation test revealed (p <= 0.001) an inverse association of SmO2-m.intercostales with V?O-2 (rho = -0.64), VE (rho = -0.73), RR (rho = -0.70), and Vt (rho = -0.63). The relationship with the ventilatory variables showed that increased breathing effort during exercise could be registered adequately using a NIRS portable device.
引用
收藏
页码:2653 / 2659
页数:7
相关论文
共 50 条
  • [21] Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis
    Sendra-Perez, Carlos
    Sanchez-Jimenez, Jose Luis
    Marzano-Felisatti, Joaquin Martin
    Encarnacion-Martinez, Alberto
    Salvador-Palmer, Rosario
    Priego-Quesada, Jose I.
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [22] Using Portable NIRS to Compare Arm and Leg Muscle Oxygenation During Roller Skiing in Biathletes: A Case Study
    Hesford, Catherine M.
    Laing, Stewart
    Cooper, Chris E.
    [J]. OXYGEN TRANSPORT TO TISSUE XXXV, 2013, 789 : 179 - 184
  • [23] Effects of prior respiratory exercise on VO2 and intercostal muscle oxygenation kinetics during maximal incremental exercise
    Berriri, Ahmed
    Oueslati, Ferid
    Ahmaidi, Said
    [J]. ACTA PHYSIOLOGICA, 2016, 217 : 153 - 153
  • [24] A PORTABLE DEVICE FOR MEASURING ACCELERATION AND KNEE ANGLE DURING SKIING AND WALKING
    KESSLER, D
    STAHELIN, M
    MATTER, P
    ZSCHOKKEGRANACHER, J
    [J]. HELVETICA CHIRURGICA ACTA, 1987, 54 (04) : 457 - 462
  • [25] A new device for measuring isometric force of the craniocervical flexor and extensor muscles and its reliability
    Bokaee, Fateme
    Rezasoltani, Asghar
    Manshadi, Farideh Dehghan
    Naimi, Sedigheh Sadat
    Baghban, Alireza Akbarzadeh
    [J]. CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2017, 35 (04): : 238 - 243
  • [26] Bootstrap Analyses of Anxiety Index Measuring the Prefrontal Cortex of Subjects at Rest with Two-Channel Portable NIRS Device
    Matsumoto, Takashi
    Murayama, Yuta
    Sakatani, Kaoru
    [J]. INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2017, 33 (05) : 399 - 409
  • [27] Validation of a new portable ergospirometric device (Oxycon Mobile®) during exercise
    Perret, C.
    Mueller, G.
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2006, 27 (05) : 363 - 367
  • [28] Electromyographic Analysis of the Lumbar Extensor Muscles during Dynamic Exercise on a Home Exercise Device
    Mayer, John M.
    Udermann, Brian E.
    Verna, Joe L.
    [J]. JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2022, 7 (01)
  • [29] Muscle Oxygenation during Cycle Exercise under Normoxic and Hypoxic Conditions - Near Infrared Spectroscopy (NIRS)
    Franke, Julia
    Geraskin, Dimitri
    Andre, Christiane
    Kohl-Bareis, Matthias
    Vega, Sandra Rojas
    Wahrmann, Berta Vera
    Bloch, Wilhelm
    Platen, Petra
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S63 - S63
  • [30] PARADOXICAL OXYGENATION OF MUSCLE DURING EXERCISE BY PATIENTS WITH DERMATOMYOSITIS AS DETECTED BY NEAR-INFRARED SPECTROSCOPY (NIRS)
    PARK, JH
    OLSEN, NJ
    LECH, G
    STEWARD, KR
    NEWMAN, J
    ADAMSGANDHI, LB
    KING, LE
    CHANCE, B
    [J]. ARTHRITIS AND RHEUMATISM, 1995, 38 (09): : 96 - 96