Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study

被引:5
|
作者
Chen, Fang [1 ]
Liu, Jia [2 ]
Zhang, Xinran [2 ]
Zhang, Daoqiang [1 ]
Liao, Hongen [2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Comp Sci & Engn, Nanjing 210016, Peoples R China
[2] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 10084, Peoples R China
基金
中国博士后科学基金;
关键词
Endovascular navigation; Ultrasound imaging; Catheter shape estimation; Further study; ABDOMINAL AORTIC-ANEURYSM; GUIDANCE; FLUOROSCOPY; ANGIOGRAPHY; TRACKING; REPAIR;
D O I
10.1109/JBHI.2020.3026105
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Two-dimensional fluoroscopy is the standard guidance imaging method for closed endovascular intervention. However, two-dimensional fluoroscopy lacks depth perception for the intervention catheter and causes radiation exposure for both surgeons and patients. In this paper, we extend our previous study and develop the improved three-dimensional (3D) catheter shape estimation using ultrasound imaging. In addition, we perform further quantitative evaluations of endovascular navigation. Method: First, the catheter tracking accuracy in ultrasound images is improved by adjusting the state vector and adding direction information. Then, the 3D catheter points from the catheter tracking are further optimized based on the 3D catheter shape optimization with a high-quality sample set. Finally, the estimated 3D catheter shapes from ultrasound images are overlaid with preoperative 3D tissue structures for the intuitive endovascular navigation. Results: the tracking accuracy of the catheter increased by 24.39%, and the accuracy of the catheter shape optimization step also increased by approximately 17.34% compared with our previous study. Furthermore, the overall error of catheter shape estimation was further validated in the catheter intervention experiment of in vitro cardiovascular tissue and in a vivo swine, and the errors were 2.13 mm and 3.37 mm, respectively. Conclusion: Experimental results demonstrate that the improved catheter shape estimation using ultrasound imaging is accurate and appropriate for endovascular navigation. Significance: Improved navigation reduces the radiation risk because it decreases use of X-ray imaging. In addition, this navigation method can also provide accurate 3D catheter shape information for endovascular surgery.
引用
收藏
页码:3616 / 3629
页数:14
相关论文
共 50 条
  • [21] Estimation of 2D/3D rigid transformation for Computer-assisted Endovascular Navigation
    Castro, Miguel
    Goeksu, Cemil
    Haigron, Pascal
    Lucas, Antoine
    Urbano, Luis
    2008 3RD INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGIES: FROM THEORY TO APPLICATIONS, VOLS 1-5, 2008, : 1099 - +
  • [22] 3D SHAPE ESTIMATION OF AN ACTIVE NEEDLE INSIDE TISSUE USING 2D ULTRASOUND IMAGES
    Konh, Bardia
    Batsaikhan, Zolboo
    Padasdao, Blayton
    PROCEEDINGS OF THE 2021 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2021), 2021,
  • [23] 3D imaging, planning, navigation
    Nolte, LP
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2003, 12 (1-2) : 3 - 4
  • [24] Characterization of a 3D Printed Endovascular Magnetic Catheter
    Ansari, Mohammad Hasan Dad
    Ha, Xuan Thao
    Ourak, Mouloud
    Borghesan, Gianni
    Iacovacci, Veronica
    Vander Poorten, Emmanuel
    Menciassi, Arianna
    ACTUATORS, 2023, 12 (11)
  • [25] Error Analysis for a navigation system using 3D abdominal ultrasound
    Iommi, David
    Valladares, Alejandra
    Figl, Michael
    Hummel, Johann
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [26] A navigation system for flexible endoscopes using abdominal 3D ultrasound
    Hoffmann, R.
    Kaar, M.
    Bathia, Amon
    Bathia, Amar
    Lampret, A.
    Birkfellner, W.
    Hummel, J.
    Figl, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5545 - 5558
  • [27] 3D ultrasound navigation in syrinx surgery - a feasibility study - Comment
    Unsgaard, G
    ACTA NEUROCHIRURGICA, 2005, 147 (05) : 540 - 541
  • [28] 3D Visualisation of Navigation Catheters for Endovascular Procedures Using a 3D Hub and Fiber Optic RealShape Technology: Phantom Study Results
    Bydlon, Torre M.
    Torjesen, Alyssa
    Fokkenrood, Steven
    Di Tullio, Alessandra
    Flexman, Molly L.
    EJVES VASCULAR FORUM, 2023, 59 : 24 - 30
  • [29] 3D ultrasound imaging with echocardiogram and a 3D positioner
    Oshiro, O
    Tanoshima, E
    Matani, A
    Chihara, K
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 835 - 836
  • [30] MIMO Radar 3D Imaging with Improved Rotation Parameters Estimation
    Ma, Changzheng
    Yeo, Tat-Soon
    Chong, Chin Yuan
    Zhang, Tao
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 214 - 220