Comparison of a Wearable Tracker with Actigraph for Classifying Physical Activity Intensity and Heart Rate in Children

被引:21
|
作者
Kang, Seoungki [1 ]
Kim, Youngdeok [2 ]
Byun, Wonwoo [3 ]
Suk, JinSu [1 ]
Lee, Jung-Min [4 ]
机构
[1] Yongin Univ, Grad Sch Educ, 134 Yongindaehak Ro, Yongin 449714, South Korea
[2] Virginia Commonwealth Univ, Dept Kinesiol & Hlth Sci, Med Coll Virginia Campus, Richmond, VA 23284 USA
[3] Univ Utah, Dept Hlth Kinesiol & Recreat, 250 S 1850 E HPER North,Room 205, Salt Lake City, UT 84108 USA
[4] Kyung Hee Univ, Coll Phys Educ, Dept Phys Educ, 1732 Deogyeong Daero, Yongin 17104, South Korea
基金
新加坡国家研究基金会;
关键词
accelerometer; Fitbit; physical activity classification; VALIDATION; CLASSIFICATION; ACCELEROMETER; RELIABILITY; EXERCISE; CONSUMER; VALIDITY; MONITOR; DESIGN; YOUTH;
D O I
10.3390/ijerph16152663
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: To examine the validity and reliability of the Fitbit Charge HR (FCH), wrist-worn ActiGraph (AG) accelerometers were used for assessing the classification of physical activity (PA) into intensity categories in children. Methods: Forty-three children (n = 43) participated in the study. Each participant completed 3 min bouts of 12 PAs ranging from sedentary to vigorous intensity while simultaneously wearing FCH and AG on both hands, a Polar HR monitor, and a portable indirect calorimeter. Total time spent in different PA intensity levels measured by FCH and AG were compared to the indirect calorimetry. Results: The highest classification accuracy values of sedentary behavior was 81.1% for FCH. The highest classification (72.4%) of light intensity PA was observed with Crouter's algorithm from the non-dominant wrist. Crouter's algorithm also show the highest classification (81.8%) for assessing moderate to vigorous intensity PA compared to FCH (70.8%). Across the devices, a high degree of reliability was found in step measurements, ranging from an intra-class correlation (ICC) = 0.92 to an ICC = 0.94. The reliability of the AG and the FCH showed high agreement for each variable. Conclusion: The FCH shows better validity for estimating sedentary behavior and similar validity for assessing moderate to vigorous PA compared to the research-grade monitor. Across the devices, the reliability showed the strongest association.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Using Heart Rate and Accelerometry to Define Quantity and Intensity of Physical Activity in Older Adults
    Schrack, Jennifer A.
    Leroux, Andrew
    Fleg, Jerome L.
    Zipunnikov, Vadim
    Simonsick, Eleanor M.
    Studenski, Stephanie A.
    Crainiceanu, Ciprian
    Ferrucci, Luigi
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2018, 73 (05): : 668 - 675
  • [42] Heart Rate Variability and Activity Magnitude Measuring Wearable Heart Rate Sensor in Depression
    Komatsu, Yoko
    Koga, Norie
    Kimura, Hiroshi
    Shinozaki, Ryo
    Shimizu, Yusuke
    Kunugi, Hiroshi
    Transactions of Japanese Society for Medical and Biological Engineering, 2021, Annual59 (Proc): : 632 - 634
  • [43] Impact of ActiGraph sampling rate on free-living physical activity measurement in youth
    Clevenger, Kimberly A.
    Brond, Jan C.
    Mackintosh, Kelly A.
    Pfeiffer, Karin A.
    Montoye, Alexander H. K.
    McNarry, Melitta A.
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (10)
  • [44] Current agreement between ActiGraph and CUPAR in measuring moderate to vigorous intensity physical activity for adolescents
    Lu, Yijuan
    Hu, Liang
    Yu, Kehong
    BMC PEDIATRICS, 2024, 24 (01)
  • [45] Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
    Santos-Lozano, A.
    Santin-Medeiros, F.
    Cardon, G.
    Torres-Luque, G.
    Bailon, R.
    Bergmeir, C.
    Ruiz, J. R.
    Lucia, A.
    Garatachea, N.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (11) : 975 - 982
  • [46] Comparison Of Polar Active And Wrist Worn Actigraph On Habitual Measures Of Physical Activity In Elementary School-aged Children
    Finn, Kevin J.
    Drumheller, Chelsea K.
    Kinnunen, Hannu
    Virtanen, Paula
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 703 - 703
  • [47] Objective measurement of habitual sedentary behaviour and physical activity in pre-school children: Comparison of activPAL with Actigraph monitors
    Martin, A.
    McNeill, M.
    Penpraze, V.
    Dall, P.
    Granat, M.
    Paton, J. Y.
    Reilly, J. J.
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2011, 70 (OCE1) : E4 - E4
  • [48] VALIDITY OF A PHYSICAL ACTIVITY TRACKER FOR HEART RATE MEASUREMENT DURING AEROBIC EXERCISE IN PEOPLE WITH PARKINSON'S DISEASE
    Mak, M.
    Ren, L.
    Kong, L.
    Wong, I.
    PARKINSONISM & RELATED DISORDERS, 2020, 79 : E42 - E43
  • [49] COMPARISON OF MOTION SENSOR AND HEART RATE MONITOR FOR ASSESSMENT OF PHYSICAL ACTIVITY INTENSITY IN STROKE OUTPATIENT REHABILITATION SESSIONS: AN OBSERVATIONAL STUDY
    Goncalves, Stephanie
    Mandigout, Stephane
    Le Bourvellec, Morgane
    Duclos, Noemie C.
    JOURNAL OF REHABILITATION MEDICINE, 2024, 56
  • [50] Promoting physical activity using a wearable activity tracker in college students: A cluster randomized controlled trial
    Kim, Youngdeok
    Lumpkin, Angela
    Lochbaum, Marc
    Stegemeier, Steven
    Kitten, Karla
    JOURNAL OF SPORTS SCIENCES, 2018, 36 (16) : 1889 - 1896