Diagnosis and management challenges in patients with mild haemophilia A and discrepant FVIII measurements

被引:43
|
作者
Trossaert, M. [1 ]
Lienhart, A. [2 ]
Nougier, C. [3 ]
Fretigny, M. [3 ]
Sigaud, M. [1 ]
Meunier, S. [2 ]
Fouassier, M. [1 ]
Ternisien, C. [1 ]
Negrier, C. [2 ,4 ]
Dargaud, Y. [2 ,4 ]
机构
[1] CHU Nantes, Ctr Reg Traitement Hemophilie, F-44035 Nantes 01, France
[2] CHU Lyon, Unite Hemostase Clin, Lyon, France
[3] CHU Lyon, Lab Hemostase, Lyon, France
[4] Univ Lyon 1, EA Unite Rech Hemophilie 4174, F-69365 Lyon, France
关键词
bleeding; bleeding score; FVIII; genotype; mild haemophilia A; thrombin generation; CALIBRATED AUTOMATED THROMBOGRAPHY; THROMBIN GENERATION MEASUREMENT; FACTOR-VIII; ONE-STAGE; ASSAY DISCREPANCY; FAMILIAL DISCREPANCY; MUTATIONS; SUBGROUP; STANDARDIZATION; PHENOTYPE;
D O I
10.1111/hae.12381
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thirty per cent of patients with mild haemophilia A (MHA) present markedly different FVIII: C level when assayed by one-stage clotting and two-stage chromogenic assays. It is, therefore, a real clinical challenge to predict the individual bleeding risk of these patients. The aim of the present work was to study the relationship between the bleeding tendency of these patients with the results of a panel of phenotypic and genotypic tools. Thirty-six patients with MHA were included in this multicentre prospective clinical study. The severity of bleeding symptoms was evaluated using the ISTH/SSC score. FVIII:C levels were measured using an activated partial thromboplastin time-based one-stage FVIII assay (FVIII: C1) and three commercial chromogenic kits (FVIII:CR). FVIII antigen levels, thrombin generation measurement and FVIII gene mutation analysis were also performed. Our results showed that a one-stage FVIII: C assay cannot rule out the diagnosis of MHA, a combined use of FVIII:C1 with a FVIII:CR is suitable for detecting MHA. We observed that FVIII:CR results better reflected the clinical bleeding tendency of patients compared to FVIII:C1. We also observed a relationship between thrombin generation (TG) capacity and FVIII:CR of these patients. FVIII gene mutation analysis showed mutations previously reported in MHA patients with discrepant FVIII:C measurements, but with no predictive value of the individual bleeding phenotype of patients. Overall, we observed a relationship between chromogenic FVIII:C results, TG assay and bleeding tendency of patients with discrepant FVIII:C measurements, while FVIII:C1 was not well correlated with clinical bleeding phenotype in this particular population.
引用
收藏
页码:550 / 558
页数:9
相关论文
共 50 条
  • [31] Specific and global coagulation assays in the diagnosis of discrepant mild hemophilia A
    Bowyer, Annette E.
    Van Veen, Joost J.
    Goodeve, Anne C.
    Kitchen, Steve
    Makrisi, Michael
    HAEMATOLOGICA, 2013, 98 (12) : 1980 - 1987
  • [32] Management of major surgery in patients with haemophilia A with continuous infusion and bolus injections of FVIII pharmacokinetic approach to therapy
    Jankovicova, Denisa
    Batorova, Angelika
    Prigancova, Tatiana
    HAEMOPHILIA, 2018, 24 : 88 - 89
  • [33] Impact of FVIII product change in severe haemophilia A patients previously treated with plasma-derived FVIII
    Mingot, M. E.
    Heiniger, A., I
    Garcia, M.
    Fernandez, J. A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 1124 - 1124
  • [34] Educational materials for patients with mild haemophilia
    Zeissink, B.
    HAEMOPHILIA, 2008, 14 : 144 - 144
  • [35] SURGICAL MANAGEMENT OF ELECTIVE SURGERY IN PATIENTS WITH MILD HAEMOPHILIA FROM A SINGLE INSTITUTION
    Lacalle, L.
    Espinosa, N.
    Segura, A.
    Calvo, J. M.
    Fernandez, N.
    Delgado, P.
    HAEMATOLOGICA, 2015, 100 : 670 - 671
  • [36] Epidemiological Challenges in Rare Bleeding Disorders: FVIII Inhibitor Incidence in Haemophilia A Patients-A Known Issue of Unknown Origin
    Keipert, Christine
    Drechsel-Baeuerle, Ursula
    Oberle, Doris
    Mueller-Olling, Mirco
    Hilger, Anneliese
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (01) : 1 - 19
  • [37] FVIII inhibitors in haemophilia A patients who are considered as previously treated patients.
    von Auer, C
    Krause, M
    Miesbach, W
    Scharrer, I
    Asmelash, G
    Stier-Brueck, I
    BLOOD, 2004, 104 (11) : 91B - 92B
  • [38] Functional FVIII assays and bleeding phenotype in 13 patients with mild haemophilia A due to the p.Tyr365Cys mutation
    Graves, E. A.
    Talks, K.
    Sergeant, K.
    Vowles, J.
    Hanley, J.
    Biss, T.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 662 - 662
  • [39] Current dosing practices for perioperative factor VIII concentrate treatment in mild haemophilia A patients result in FVIII levels above target
    Schutte, Lisette M.
    de Rooij, Nils
    Hazendonk, Hendrika C. A. M.
    Mathot, Ron A. A.
    van Hest, Reinier M.
    Leebeek, Frank W. G.
    Cnossen, Marjon H.
    Kruip, Marieke J. H. A.
    HAEMOPHILIA, 2019, 25 (06) : 960 - 968
  • [40] Specific and global coagulation assays in the diagnosis of mild haemophilia A
    Bowyer, A. E.
    Van Veen, J.
    Goodeve, A. C.
    Kitchen, S.
    Makris, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 704 - 704