Modelling nonlinear ultrasound propagation in bone

被引:0
|
作者
Cleveland, Robin O. [1 ,2 ]
Johnson, Paul A. [3 ]
Muller, Marie [2 ]
Talmant, Maryline [2 ]
Padilla, Frederic [2 ]
Laugier, Pascal [2 ]
机构
[1] Boston Univ, Dept Aerosp & Mech Engn, 110 Cummington St, Boston, MA 02215 USA
[2] Univ Paris 06, CNRS, UMR 7623, Lab Imagerie Parametr, F-75006 Paris, France
[3] Los Alamos Natl Lab, MS D443, Geophys Grp, Los Alamos, NM 87545 USA
来源
基金
美国国家科学基金会;
关键词
nonlinear acoustics; bone properties; harmonic generation; self-demodulation;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Simulations have been carried out to assess the possibility for detecting the nonlinear properties of bone in vivo. We employed a time domain solution to the KZK equation to determine the nonlinear field generated by an unfocussed circular transducer in both cancellous and cortical bone. The results indicate that determining nonlinear properties from the generation of higher harmonics is challenging in both bone types (for propagation distances and source amplitudes appropriate in the body). In cancellous bone this is because the attenuation length scale is very short (about 5 mm) and in cortical bone because the high sound speed and density result in long nonlinear length scales (hundreds of millimeters). An alternative approach to determine the nonlinear properties was considered using self-demodulation of sound. For cancellous bone this may result in a detectable signal although the predicted amplitude of the self-demodulation signal was almost 90 dB below the source level (1 MPa). In cortical bone the self-demodulated signal was even weaker that in cancellous bone (similar to 110 dB down) and, for a practical length signal, was not easy to separate from the components associated with the source
引用
收藏
页码:333 / +
页数:2
相关论文
共 50 条
  • [31] Full-wave modeling of therapeutic ultrasound: Nonlinear ultrasound propagation in ideal fluids
    Ginter, S
    Liebler, M
    Steiger, E
    Dreyer, T
    Ridelinger, RE
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 111 (05): : 2049 - 2059
  • [32] Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound
    School of Physics, University of Bath, Claverton Down, Bath BA2 7AY, United Kingdom
    J. ACOUST. SOC. AM., 1 (143-154):
  • [33] Higher order Nonlinear ultrasound propagation in tissue - Simulation study
    Haider, B
    Krishnan, K
    Thomenius, K
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1737 - 1740
  • [34] Impact of nonlinear propagation on temperature distributions caused by diagnostic ultrasound
    Thomenius, KE
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1409 - 1413
  • [35] Effects of nonlinear ultrasound propagation on output display indices - Introduction
    Carson, PL
    JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (01) : 27 - 31
  • [36] Influence of the abdominal wall on the nonlinear propagation of focused therapeutic ultrasound
    刘振波
    范庭波
    章东
    龚秀芬
    Chinese Physics B, 2009, 18 (11) : 4932 - 4937
  • [37] Nonlinear propagation applied to the improvement of resolution in diagnostic medical ultrasound
    Ward, B
    Baker, AC
    Humphrey, VF
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01): : 143 - 154
  • [38] Effects of nonlinear ultrasound propagation on high intensity brain therapy
    Pinton, Gianmarco
    Aubry, Jean-Francois
    Fink, Mathias
    Tanter, Mickael
    MEDICAL PHYSICS, 2011, 38 (03) : 1207 - 1216
  • [39] THEORY OF NONLINEAR PROPAGATION OF SHORT-WAVE ULTRASOUND IN SEMICONDUCTORS
    MISHIN, AG
    FIZIKA TVERDOGO TELA, 1975, 17 (11): : 3455 - 3456
  • [40] Nonlinear propagation in ultrasonic fields: measurements, modelling and harmonic imaging
    Humphrey, VF
    ULTRASONICS, 2000, 38 (1-8) : 267 - 272