Ultrasound-guided pleural cutting needle biopsy: accuracy and factors influencing diagnostic yield

被引:23
|
作者
Zhang, Yuxin [1 ]
Tang, Jiaxin [2 ]
Zhou, Xinghua [1 ]
Zhou, Dazhi [1 ]
Wang, Jinlin [2 ]
Tang, Qing [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 1, Dept Ultrasound, 151 Rd Yanjiang, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Affiliated Hosp 1, Guangzhou Inst Resp Dis, Dept Resp Dis,State Key Lab Resp Dis,China Clin R, Guangzhou 510120, Guangdong, Peoples R China
关键词
Ultrasound-guided pleural biopsy; cutting needle; influencing factors; diagnostic accuracy; retrospective study; TRU-CUT NEEDLE; CONTROLLED-TRIAL; EFFUSION; CT; DISEASE; MESOTHELIOMA; ABRAMS; COMPLICATIONS; THORACOSCOPY; PHYSICIAN;
D O I
10.21037/jtd.2018.05.94
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The aim of this study was to retrospectively investigate the diagnostic accuracy of ultrasound-guided pleural cutting needle biopsy (US-guided PCNB) and the potential factors influencing diagnostic yield. Methods: From July 2014 to June 2016, a total of 147 percutaneous US-guided PCNBs in 144 patients were retrospectively reviewed. The final diagnosis was confirmed by histopathological analysis and followup. We calculated diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) and divided all cases into group of correct diagnoses (true-positive and true-negative cases) and group of incorrect diagnoses (false-positive, false-negative, and inconclusive cases). Univariate and multivariate logistic regression analyses were performed to analyze the differences of influencing factors (patient, pleura, and biopsy-associated factors) in the between the two groups. Results: Seven patients were excluded because of loss to follow-up. A total of 140 cases were ultimately included (105 males and 35 females). "There were 105 cases in the correct diagnosis group, and 35 cases in the incorrect diagnosis group. The overall accuracy of US-NCNB was 75.0% and the sensitivity, specificity, PPV, NPV in malignant diagnosis were 58.1%, 99.0%, 96.2%, and 84.2%, respectively. On univariate analysis, variables affecting diagnostic accuracy of US-PCNB were the pleural thickness (<3 mm in thickness 61.0%, >= 3 mm in thickness 85.2%; P=0.001), morphology (non-nodular pleura 71.4%, nodular pleura 95.2%; P=0.026), and needle size (18 G 69.1%, 16 G 87.0%; P=0.022). Finally multivariate logistic regression demonstrated that pleural thickness [odds ratio (OR): 0.278, P=0.003] and needle size (OR: 0.291, P=0.018) independently predicted diagnostic accuracy. Conclusions: Pleural thickness and the size of the biopsy needle were significantly correlated with the diagnostic yield.
引用
收藏
页码:3244 / 3252
页数:9
相关论文
共 50 条
  • [31] Computed tomography-guided cutting needle pleural biopsy: Accuracy and complications
    Cao, Yi-Yuan
    Fan, Na
    Xing, Fen
    Xu, Li-Ying
    Qu, Yan-Juan
    Liao, Mei-Yan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 9 (01) : 262 - 266
  • [32] Diagnostic yield of Xpert MTB/RIF on contrast-enhanced ultrasound-guided pleural biopsy specimens for pleural tuberculosis
    Sun, Wenwen
    Zhou, Yiming
    Li, Wenting
    Wang, Yin
    Xiong, Kunlong
    Zhang, Zhemin
    Fan, Lin
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 108 : 89 - 95
  • [33] ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION BIOPSY AND FINE NEEDLE CUTTING BIOPSY - CLINICAL EFFICACY IN ONCOLOGY
    WANDT, H
    GRUMMICH, H
    FALGE, C
    ZIPPEL, R
    GALLMEIER, WM
    WUNSCH, PH
    TUMORDIAGNOSTIK & THERAPIE, 1991, 12 (02) : 79 - 82
  • [34] Accuracy of ultrasound-guided, large-core needle breast biopsy
    Schueller, G.
    Schueller-Weidekamm, C.
    Helbich, T. H.
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1761 - 1773
  • [35] Ultrasound-guided needle biopsy of the breast
    Staren, ED
    O'Neill, TP
    SURGERY, 1999, 126 (04) : 629 - 634
  • [36] Accuracy of ultrasound-guided, large-core needle breast biopsy
    G. Schueller
    C. Schueller-Weidekamm
    T. H. Helbich
    European Radiology, 2008, 18
  • [37] Safety and Diagnostic Yield of Endoscopic Ultrasound-Guided Fine-Needle Biopsy for Hypervascular Pancreatic Lesions
    Hamamoto, Wataru
    Onoyama, Takumi
    Kawahara, Shiho
    Sakamoto, Yuri
    Koda, Hiroki
    Yamashita, Taro
    Takeda, Yohei
    Matsumoto, Kazuya
    Harada, Kenichi
    Yamaguchi, Naoyuki
    Isomoto, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [38] Diagnostic accuracy of ultrasound-guided core needle biopsy versus incisional biopsy in soft tissue sarcoma: an institutional experience
    Cernakova, Miroslava
    Hobusch, Gerhard M.
    Amann, Gabriele
    Funovics, Philipp T.
    Windhager, Reinhard
    Panotopoulos, Joannis
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [39] Diagnostic Value of Ultrasound-Guided Needle Biopsy in Undiagnosed Pleural Effusions: A Systematic Review and Meta-Analysis
    Lin, Z.
    Wang, J.
    Wu, D.
    Wang, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [40] Diagnostic value of ultrasound-guided needle biopsy in undiagnosed pleural effusions A systematic review and meta-analysis
    Lin, Zhidi
    Wu, Donghong
    Wang, Jinlin
    Wang, Chuqiao
    Huang, Mingkai
    MEDICINE, 2020, 99 (27) : E21076