The filter/moderator arrangement-optimisation for the boron-neutron capture therapy (BNCT)

被引:2
|
作者
Tracz, G
Dabkowski, L
Dworak, D
Pytel, K
Woznicka, U
机构
[1] Polish Acad Sci, Henry Niewodniczanski Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Inst Atom Energy, PL-05400 Otwock, Poland
关键词
D O I
10.1093/rpd/nch145
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The paper presents results of the numerical modelling of the fission-converter-based epithermal neutron source designed for the boron neutron capture therapy (BNCT) facility to be located at the Polish research nuclear reactor MARIA at Swierk. The unique design of the fission converter has been proposed due to a specific geometrical surrounding of the reactor. The filter/moderator arrangement has been optimised to moderate fission neutrons to epithermal energies and to remove both fast neutrons and photons from the therapeutic beam. The selected filter/moderator set-up ensures both high epithermal neutron flux and suitably low level of beam contamination. Photons originating from the reactor core are almost eliminated what is the exceptional advantage of the proposed design. It yields one order of magnitude lower gamma radiation dose than the maximum allowed dose in such a type of therapeutic facility. The MCNP code has been used for the computations.
引用
收藏
页码:827 / 831
页数:5
相关论文
共 50 条
  • [21] Use of a Xenon Gamma Spectrometer for Dosimetry in Boron-Neutron Capture Therapy
    Khimmatov, I. F.
    Ulin, S. E.
    PHYSICS OF ATOMIC NUCLEI, 2024, 87 (05) : 620 - 624
  • [22] Polymers and boron neutron capture therapy (BNCT): a potent combination
    Pitto-Barry, Anais
    POLYMER CHEMISTRY, 2021, 12 (14) : 2035 - 2044
  • [23] Clinical results of boron neutron capture therapy (BNCT) for glioblastoma
    Kageji, T.
    Mizobuchi, Y.
    Nagahiro, S.
    Nakagawa, Y.
    Kumada, H.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1823 - 1825
  • [24] Synthesis and evaluation of boron folates for Boron-Neutron-Capture-Therapy (BNCT)
    Kettenbach, Kathrin
    Schieferstein, Hanno
    Grunewald, Catrin
    Iffland, Dorothee
    Reffert, LauraM.
    Hampel, Gabriele
    Schuetz, Christian L.
    Bings, Nicolas H.
    Ross, Tobias L.
    RADIOCHIMICA ACTA, 2015, 103 (11) : 799 - 809
  • [25] Boron analysis and boron imaging in biological materials for Boron Neutron Capture Therapy (BNCT)
    Wittig, Andrea
    Michel, Jean
    Moss, Raymond L.
    Stecher-Rasmussen, Finn
    Arlinghaus, Heinrich F.
    Bendel, Peter
    Mauri, Pier Luigi
    Altieri, Saverio
    Hilger, Ralf
    Salvadori, Piero A.
    Menichetti, Luca
    Zamenhof, Robert
    Sauerwein, Wolfgang A. G.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 68 (01) : 66 - 90
  • [26] IMPROVED MONITORING-SYSTEM OF NEUTRON-FLUX DURING BORON-NEUTRON CAPTURE THERAPY
    HARASAWA, S
    NAKAMOTO, A
    HAYAKAWA, Y
    EGAWA, J
    AIZAWA, O
    NOZAKI, T
    MINOBE, T
    HATANAKA, H
    RADIATION RESEARCH, 1981, 88 (01) : 187 - 193
  • [27] POSSIBLE ALTERATION OF THE BLOOD-BRAIN-BARRIER BY BORON-NEUTRON CAPTURE THERAPY
    HATANAKA, H
    MORITANI, M
    CAMILLO, M
    ACTA ONCOLOGICA, 1991, 30 (03) : 375 - 378
  • [28] Evaluations for prompt-gamma imaging of boron and hydrogen neutron capture reactions in boron neutron capture therapy (BNCT)
    Auterinen, I
    Kotiluoto, P
    Anttila, K
    Serén, T
    Kekki, T
    Renvall, T
    Tiitta, A
    Kaschuck, Y
    Trykov, L
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 887 - 890
  • [29] Preliminary study of MAGAT polymer gel dosimetry for boron-neutron capture therapy
    Hayashi, Shin-ichiro
    Sakurai, Yoshinori
    Uchida, Ryohei
    Suzuki, Minoru
    Usui, Shuji
    Tominaga, Takahiro
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [30] A SIMPLE AND IMPROVED SYNTHESIS OF P-BORONOPHENYLALANINE, A BORON CARRIER FOR THE BORON-NEUTRON CAPTURE THERAPY
    KIRIHARA, M
    MORIMOTO, T
    ICHIMOTO, I
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 1993, 57 (11) : 1940 - 1941