Impulse characteristics of 24 kV overhead line pin insulators

被引:0
|
作者
Taklaja, Paul [1 ]
Hyvonen, Petri [1 ]
Niitsoo, Jaan [1 ]
Palu, Ivo [1 ]
Kluss, Joni [2 ]
机构
[1] Tallinn Univ Technol, Dept Elect Power Engn, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] Aalto Univ, Dept Elect Engn, Espoo 02150, Finland
关键词
Insulator; flashover; breakdown; lightning stroke; volt-time characteristic;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
One of the main characteristics of the distribution grid is the reliability of medium voltage overhead lines which can be improved by appropriate insulation coordination. This paper assesses common insulator types in Estonia. Old glass pin insulators and newly installed porcelain pin insulators were tested against different lightning overvoltages (impulse flashovers) in order to determine their volt-time characteristics. Test results show convincingly that the new porcelain pin insulators can be easily physically broken when stressed by lightning impulses. This can lead to the numeral increase of outages in medium voltage overhead lines in the distribution grid.
引用
收藏
页码:545 / 549
页数:5
相关论文
共 50 条
  • [21] DIELECTRIC STRENGTH OF OVERHEAD LINE INSULATORS UNDER OVERVOLTAGE CONDITIONS
    ALEKSANDROV, GN
    GERASIMOV, YA
    ELECTRICAL TECHNOLOGY, 1995, (02): : 121 - 130
  • [22] Lightning Impulse Arc Development Process and Flashover Characteristics of 110 kV SIR Insulators Under Heavy Rainstorms
    Dong B.
    Song J.
    Li T.
    Li J.
    Jiang X.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (02): : 525 - 535
  • [23] Breakdown of 15 kV Insulators under Bipolar Oscillating Impulse Voltage
    Silva, Alexandre Rigotti
    Piantini, Alexandre
    da Silva, Daiana A.
    Shigihara, Miltom
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [24] Investigation of electrical failures in porcelain cap and pin line insulators
    Mishra, A. P.
    Gorur, R. S.
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 95 - 98
  • [25] SWITCHING IMPULSE CHARACTERISTICS OF UHV STATION POST INSULATORS
    HILEMAN, AR
    ASKINS, HW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (01): : 139 - 144
  • [26] Failure characteristics of suspension-type porcelain insulators on a 154kV transmission line
    Han, Se-Won
    Cho, Han-Goo
    Choi, In-Hyuk
    Lee, Dong-Il
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 118 - +
  • [27] Switching transients in overhead transmission line 220 kV
    Vasileva, Margreta
    Stanchev, Danail
    7TH INTERNATIONAL CONFERENCE ON ENERGY EFFICIENCY AND AGRICULTURAL ENGINEERING (EE&AE), 2020,
  • [28] Funan suburb 35 kV overhead line design
    Wang, Hong-Ling
    Zhang, Yuan-Min
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (06): : 88 - 90
  • [29] Corona noise on a 400 kV overhead power line
    Mujcic, A
    Suljanovic, N
    Zajc, M
    Tasic, JF
    ELECTRICAL ENGINEERING, 2004, 86 (02) : 61 - 67
  • [30] Performance of 400 kV line insulators under pollution
    Arora, Ravindra
    Rai, Manoj
    Yadav, Satyendra Kumar
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 136 - +