Impulse characteristics of 24 kV overhead line pin insulators

被引:0
|
作者
Taklaja, Paul [1 ]
Hyvonen, Petri [1 ]
Niitsoo, Jaan [1 ]
Palu, Ivo [1 ]
Kluss, Joni [2 ]
机构
[1] Tallinn Univ Technol, Dept Elect Power Engn, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
[2] Aalto Univ, Dept Elect Engn, Espoo 02150, Finland
关键词
Insulator; flashover; breakdown; lightning stroke; volt-time characteristic;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
One of the main characteristics of the distribution grid is the reliability of medium voltage overhead lines which can be improved by appropriate insulation coordination. This paper assesses common insulator types in Estonia. Old glass pin insulators and newly installed porcelain pin insulators were tested against different lightning overvoltages (impulse flashovers) in order to determine their volt-time characteristics. Test results show convincingly that the new porcelain pin insulators can be easily physically broken when stressed by lightning impulses. This can lead to the numeral increase of outages in medium voltage overhead lines in the distribution grid.
引用
收藏
页码:545 / 549
页数:5
相关论文
共 50 条
  • [1] Volt-Time Characteristics of Medium Voltage Overhead Line Porcelain Pin Insulators
    Taklaja, Paul
    Hyvoenen, Petri
    Niitsoo, Jaan
    Palu, Ivo
    Kluss, Joni
    Kutt, Lauri
    PROCEEDINGS OF THE 14TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2013, 2013, : 423 - 427
  • [3] EVALUATION OF PLASTICS INSULATORS FOR USE ON BRITISH RAILWAYS 25-KV OVERHEAD LINE ELECTRIFICATION
    GOLDRING, AG
    SUDDARDS, AD
    LOOMS, JST
    EDWARDS, DR
    MASON, JH
    BANKS, VAA
    ECCLESTONE, BG
    BRADWELL, A
    WHEELER, JCG
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1983, 130 (04): : 284 - 288
  • [4] EVALUATION OF PLASTICS INSULATORS FOR USE ON BRITISH RAILWAYS 25KV OVERHEAD LINE ELECTRIFICATION
    BRADWELL, A
    WHEELER, JCG
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1982, 129 (03): : 101 - 110
  • [5] Modelling of the Positive Lightning Impulse Flashover of Medium Voltage Overhead Line Insulators using ATP/EMTP
    Mikropoulos, Pantelis N.
    Tsouris, Petros P.
    2022 36TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2022), 2022, : 535 - 539
  • [6] Contaminated Insulators on 220 kV Overhead Lines.
    Kaiser, F.
    1600, (37):
  • [7] AC Flashover Performance for Line Post and Pin Post Insulators in Distribution 22 kV.
    Thipprasert, W.
    Sritakeaw, P.
    Jirapong, P.
    2012 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2012, : 464 - 468
  • [8] Phase-time analysis of the leakage impulse current of faulty line-post pin insulators
    Kim, CJ
    Momoh, JA
    Lee, HJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) : 323 - 328
  • [9] Dynamics characteristic of V-string composite insulators for 330kV overhead transmission line
    Hou, Lei
    Wang, Liming
    Guan, Zhicheng
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 429 - 432
  • [10] Volt-time Curves of 24 kV Porcelain Insulators under Non-Standard Impulse Waveshapes
    Shigihara, M.
    Piantini, A.
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,