Uncemented rotating-platform total knee replacement: A five to twelve-year follow-up study

被引:57
|
作者
Sorrells, RB
Voorhorst, PE
Murphy, JA
Bauschka, MP
Greenwald, AS
机构
[1] Joint Replacement Clin, Little Rock, AR 72205 USA
[2] DePuy Orthopaed, Warsaw, IN 46581 USA
[3] Lutheran Gen Hosp, Cleveland Clin, Hlth Syst, Orthopaed Res Labs, Cleveland, OH 44113 USA
来源
关键词
D O I
10.2106/00004623-200410000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Mobile-bearing knee designs represent an alternative to conventional fixed-bearing total knee arthroplasty. We present the results of a prospective, intermediate-term clinical follow-up study of the bicruciate ligament-sacrificing porous-coated Low Contact Stress rotating-platform total knee design. Methods: Between February 1984 and January 1994, 528 uncemented primary knee replacements were performed in 421 patients. All patellae were resurfaced with use of the Low Contact Stress rotating patellar component. The average age of the patients at the time of the index procedure was sixty-nine years. The study group included 261 women and 160 men. Patients were evaluated at three months, six months, and yearly thereafter with use of the 100-point New Jersey Orthopaedic Hospital knee-scoring system. In addition, a radiographic analysis of the tibial, femoral, and patellar components was performed at each interval. Results: There were twenty-nine failures that resulted in revision. The Kaplan-Meier estimate of implant survival at twelve years was 89.5% (95% confidence interval, 83.4% to 95.6%). The total clinical scores improved significantly compared with the preoperative scores for the first twelve months postoperatively and then plateaued. Three hundred and twenty-one knees had adequate radiographic follow-up (average, 8.1 years; range, five to twelve years). Zonal radiographic analysis revealed ninety-three instances of radiolucent lines (eighty-two of which measured <1 mm in width), with the greatest number of radiolucent lines (thirty-nine) being located around the tibial tray stem. None of these lines were deemed to be progressive, and no knee with a radiolucent line that measured >2 mm was revised because of failure. Conclusions: This first-generation uncemented, mobile-bearing, bicruciate ligament-sacrif icing knee replacement was associated with a good survival rate and demonstrated clinical efficacy during the five to twelve-year follow-up interval. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:2156 / 2162
页数:7
相关论文
共 50 条
  • [31] HERBERT TOTAL KNEE REPLACEMENT - LONGER THAN 3 YEAR FOLLOW-UP
    RITTER, MA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1977, (129) : 232 - 235
  • [32] Patient Preferences for Total Knee Replacement Surgery: Two Year Follow-up
    Vina, Ernest
    Ran, Di
    Ashbeck, Erin
    Ibrahim, Said
    Hannon, Michael J.
    Zhou, Jin
    Kwoh, C. Kent
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [33] A 15 to 17-year follow-up of the Kinemax total knee replacement
    Grazette, Andrew J.
    Wylde, Vikki
    Dixon, Samantha
    Whitehouse, Sarah L.
    Blom, Ashley W.
    Whitehouse, Michael R.
    KNEE, 2018, 25 (06): : 1292 - 1298
  • [34] Twelve-Year Follow-Up of Laser In Situ Keratomileusis for Moderate to High Myopia
    Ikeda, Tetsuya
    Shimizu, Kimiya
    Igarashi, Akihito
    Kasahara, Sumie
    Kamiya, Kazutaka
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [35] Twelve-Year Follow-Up of Laser Frenectomy during Early Mixed Dentition
    Awooda, Elhadi Mohieldin
    CASE REPORTS IN DENTISTRY, 2023, 2023
  • [36] HIV infection among children in Malanje province, Angola: a twelve-year follow-up study
    Sito, Joaquim
    Nunes, Manuel L.
    Fonseca, Ana Mafalda L.
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2024, 18 (05): : 802 - 808
  • [37] Twelve-year follow-up of 137 patients with accelerated-malignant hypertension
    Bemardes, SH
    Bortolotto, LA
    Krieger, EM
    Ramires, JAF
    JOURNAL OF HYPERTENSION, 1998, 16 : S202 - S202
  • [38] Pharmacogene Variants Associated with Liver Transplant in a Twelve-Year Clinical Follow-Up
    Sendra, Luis
    Olivera, Gladys G.
    Lopez-Andujar, Rafael
    Serrano, Cristina
    Rojas, Luis E.
    Maria Montalva, Eva
    Jose Herrero, Maria
    Alino, Salvador F.
    PHARMACEUTICS, 2022, 14 (02)
  • [39] Minimally invasive surgery (MIS) for total knee replacement; medium term results with minimum five year follow-up
    Unwin, Olivia
    Hassaballa, Mohammed
    Murray, James
    Harries, William
    Porteous, Andrew
    KNEE, 2017, 24 (02): : 454 - 459
  • [40] Clinical usefulness and safety in the early phase after a newly designed rotating-platform total knee arthroplasty: A prospective multicentre cohort study with a 2-year follow up
    Ueyama, Hideki
    Kodama, Takao
    Fujikawa, Yosuke
    Ozeki, Kenji
    Nakagawa, Shigeru
    Nomura, Koji
    Fukunaga, Kenji
    Koyanagi, Junichiro
    KNEE, 2022, 39 : 269 - 278