Uncemented rotating-platform total knee replacement: A five to twelve-year follow-up study

被引:57
|
作者
Sorrells, RB
Voorhorst, PE
Murphy, JA
Bauschka, MP
Greenwald, AS
机构
[1] Joint Replacement Clin, Little Rock, AR 72205 USA
[2] DePuy Orthopaed, Warsaw, IN 46581 USA
[3] Lutheran Gen Hosp, Cleveland Clin, Hlth Syst, Orthopaed Res Labs, Cleveland, OH 44113 USA
来源
关键词
D O I
10.2106/00004623-200410000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Mobile-bearing knee designs represent an alternative to conventional fixed-bearing total knee arthroplasty. We present the results of a prospective, intermediate-term clinical follow-up study of the bicruciate ligament-sacrificing porous-coated Low Contact Stress rotating-platform total knee design. Methods: Between February 1984 and January 1994, 528 uncemented primary knee replacements were performed in 421 patients. All patellae were resurfaced with use of the Low Contact Stress rotating patellar component. The average age of the patients at the time of the index procedure was sixty-nine years. The study group included 261 women and 160 men. Patients were evaluated at three months, six months, and yearly thereafter with use of the 100-point New Jersey Orthopaedic Hospital knee-scoring system. In addition, a radiographic analysis of the tibial, femoral, and patellar components was performed at each interval. Results: There were twenty-nine failures that resulted in revision. The Kaplan-Meier estimate of implant survival at twelve years was 89.5% (95% confidence interval, 83.4% to 95.6%). The total clinical scores improved significantly compared with the preoperative scores for the first twelve months postoperatively and then plateaued. Three hundred and twenty-one knees had adequate radiographic follow-up (average, 8.1 years; range, five to twelve years). Zonal radiographic analysis revealed ninety-three instances of radiolucent lines (eighty-two of which measured <1 mm in width), with the greatest number of radiolucent lines (thirty-nine) being located around the tibial tray stem. None of these lines were deemed to be progressive, and no knee with a radiolucent line that measured >2 mm was revised because of failure. Conclusions: This first-generation uncemented, mobile-bearing, bicruciate ligament-sacrif icing knee replacement was associated with a good survival rate and demonstrated clinical efficacy during the five to twelve-year follow-up interval. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:2156 / 2162
页数:7
相关论文
共 50 条
  • [1] Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study
    Callaghan, JJ
    Squire, MW
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05): : 705 - 711
  • [2] Uncemented rotating-platform total knee arthroplasty: A 4-year to 12-year follow-up
    Ali, MS
    Mangaleshkar, SR
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01): : 80 - 84
  • [3] Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilized Total Knee Arthroplasty
    Meftah, Morteza
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (05): : 426 - 432
  • [4] Cemented Rotating-Platform Total Knee Replacement
    Callaghan, John J.
    Wells, Christopher W.
    Liu, Steve S.
    Goetz, Devon D.
    Johnston, Richard C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07): : 1635 - 1639
  • [5] Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report
    Callaghan, JJ
    O'Rourke, MR
    Iossi, MF
    Liu, SS
    Goetz, DD
    Vittetoe, DA
    Sullivan, PM
    Johnston, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09): : 1995 - 1998
  • [6] Posterior Cruciate-retaining, Rotating-platform Total Knee Arthroplasty: Minimum 4-year Follow-up Study
    Elwood, Justin J.
    Callaghan, John J.
    Liu, Steve S.
    Goetz, Devon D.
    ORTHOPEDICS, 2012, 35 (12) : E1699 - E1704
  • [7] A high-flexion design total knee prosthesis: a ten to twelve-year follow-up study
    Kim, Man Soo
    Choi, Keun Young
    Hur, Jae Hyeong
    In, Yong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [8] The Outcome of Rotating-Platform Total Knee Arthroplasty with Cement at a Minimum of Ten Years of Follow-up
    Argenson, Jean-Noel A.
    Parratte, Sebastien
    Ashour, Abdullah
    Saintmard, Bertrand
    Aubaniac, Jean-Manuel
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (07): : 638 - 644
  • [9] Safety and Efficacy of a Rotating-Platform, High-Flexion Knee Design Three- to Five-Year Follow-Up
    Meftah, Morteza
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (02): : 201 - 206
  • [10] Twelve-year follow-up of penetrating keratoplasty
    Takashi Ono
    Sosuke Ishiyama
    Takeshi Hayashidera
    Yosai Mori
    Ryohei Nejima
    Kazunori Miyata
    Shiro Amano
    Japanese Journal of Ophthalmology, 2017, 61 : 131 - 136