Non-linear Calibration of Pipeline ADCs using a Histogram-based Estimation of the Redundant INL

被引:0
|
作者
Gines, Antonio [1 ]
Leger, Gildas [1 ]
Peralias, Eduardo [1 ]
机构
[1] Univ Seville, Inst Microelect Sevilla IMSE CNM, CSIC, Av Americo Vespucio 28, Seville 41092, Spain
关键词
Pipeline ADC; Non-linearity; Redundancy; LUT-based calibration; Redundant Integral-Non-linearity (INL);
D O I
10.1109/newcas49341.2020.9159800
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a digital non-linear calibration technique for Pipeline ADCs using a novel Look-up Table (LUT) approach. Due to redundancy, the signal paths (and hence, the errors in Pipeline ADCs) are not unique for a given input level. This effect limits the performance of conventional LUT-based calibration methods using the output code of the ADC as single address in the error code LUT memory. To overcome this drawback, this work uses an estimation of true redundant INL (Integral Non-Linearity), based on the standardized histogram method. The technique resolves the presence of multiple error codes for a single input level incorporating the most significant redundant subcodes in the memory address. The advantages of the method are shown by realistic behavioral simulations and by a 0.8V(pp) 11-bit 60Msps Pipeline ADC silicon demonstrator in a 130nm CMOS process.
引用
收藏
页码:142 / 145
页数:4
相关论文
共 50 条
  • [21] Estimation of Object Position Using Non-linear Filters
    Konatowski, Stanislaw
    Kaniewski, Piotr
    Labowski, Michal
    2017 18TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2017,
  • [22] Adjustment of highly non-linear redundant systems of equations using a numerical, topology-based approach
    Saltogianni, Vasso
    Stiros, Stathis
    JOURNAL OF APPLIED GEODESY, 2012, 6 (3-4) : 125 - 134
  • [23] GA-based non-linear harmonic estimation
    Bettayeb, M
    Qidwai, U
    ARTIFICIAL NEURAL NETS AND GENETIC ALGORITHMS, 2001, : 292 - 295
  • [24] A new histogram-based estimation technique of entropy and mutual information using mean squared error minimization
    Hacine-Gharbi, A.
    Deriche, M.
    Ravier, P.
    Harba, R.
    Mohamadi, T.
    COMPUTERS & ELECTRICAL ENGINEERING, 2013, 39 (03) : 918 - 933
  • [25] Fault residuals for Compact Disc players based on redundant and non-linear sensors
    Odgaard, PF
    Stoustrup, J
    Andersen, P
    Mikkelsen, HF
    PROCEEDINGS OF THE 2004 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2004, : 1842 - 1847
  • [26] Observer for non-linear systems with sampled measurements: Application to the friction factor estimation of a pipeline
    Hernandez-Gonzalez, O.
    Ramirez-Rasgado, F.
    Astorga-Zaragoza, C. M.
    Guerrero-Sanchez, M. E.
    Valencia-Palomo, G.
    Rodriguez-Mata, A. E.
    IET CONTROL THEORY AND APPLICATIONS, 2021, 15 (03): : 432 - 445
  • [27] Non-Linear Flow Sensor Calibration Using A Fixed Volume Syringe
    Biselli, P. J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [28] Color calibration of a colorimetric scanner using non-linear least squares
    Rao, AR
    Mintzer, F
    IMAGE PROCESSING IMAGE QUALITY IMAGE CAPTURE SYSTEMS CONFERENCE, 1998, : 118 - 120
  • [29] Estimation of Radioactivity Release Activity Using Non-Linear Kalman Filter-Based Estimation Techniques
    Becerra, Victor M.
    Vajpayee, Vineet
    Bausch, Nils
    Santhosh, T., V
    Vinod, Gopika
    Deng, Jiamei
    ENERGIES, 2020, 13 (15)
  • [30] Non-linear calibration optimisation based on the Levenberg-Marquardt algorithm
    Hu, Guoliang
    Zhou, Zuofeng
    Cao, Jianzhong
    Huang, Huimin
    IET IMAGE PROCESSING, 2020, 14 (07) : 1402 - 1414