Direct-detected rapid-scan EPR at 250 MHz

被引:80
|
作者
Stoner, JW
Szymanski, D
Eaton, SS [1 ]
Quine, RW
Rinard, GA
Eaton, GR
机构
[1] Univ Denver, Dept Chem & Biochem, Denver, CO 80208 USA
[2] Univ Denver, Dept Engn, Denver, CO 80208 USA
关键词
rapid-scan; EPR; direct-detection; trityl; lithium phthalocyanine; 250 MHz EPR;
D O I
10.1016/j.jmr.2004.06.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
EPR spectra at 250 MHz for a single crystal of lithium phthalocyanine (LiPc) in the absence of oxygen and for a deoxygenated aqueous solution of a Nycomed triarylmethyl (trityl-CD3) radical were obtained at scan rates between 1.3 x 10(3) and 3.4 x 10(5) G/s, These scan rates are rapid relative to the reciprocals of the electron spin relaxation times (LiPc: T-1 = 3.5 mus and T-2 = 2.5 mus; trityl: T-1 = 12 mus and T-2 = 11.5 mus) and cause characteristic oscillations in the direct-detected absorption spectra. For a given scan rate, shorter values of T-2 and increased inhomogeneous broadening cause less deep oscillations that damp out more quickly than for longer T-2. There is excellent agreement between experimental and calculated lineshapes and signal amplitudes as a function of radiolfrequency magnetic field (B-1) and scan rate. When B-1 is adjusted for maximum signal amplitude as a function of scan rate, signal intensity for constant number of scans is enhanced by up to a factor of three relative to slow scans. The number of scans that can be averaged in a defined period of time is proportional to the scan rate, which further enhances signal amplitude per unit time. Longer relaxation times cause the maximum signal intensity to occur at slower scan rates. These experiments provide the first systematic characterization of direct-detected rapid-scan EPR signals. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 50 条
  • [31] A RAPID-SCAN CIRCULARLY SYMMETRICAL PILLBOX ANTENNA
    ROTMAN, W
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1952, 40 (02): : 228 - 228
  • [32] Multi-frequency rapid-scan HFEPR
    Laguta, O.
    Tucek, M.
    van Slageren, J.
    Neugebauer, P.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 296 : 138 - 142
  • [33] SPECTRAL SENSITIVITY BY RAPID-SCAN FLICKER PHOTOMETRY
    KAISER, PK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 172 - 172
  • [34] A 5 MHZ HIGH-VOLTAGE DEMULTIPLEXED ULTRASONIC ARRAY SYSTEM FOR RAPID-SCAN TESTING OF ADVANCED MATERIALS
    RAMOS, A
    DEESPINOSA, FRM
    SANZ, PT
    TORREGROSA, JM
    SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 : 385 - 390
  • [35] DPSK-Labeled Direct-Detected Optical OFDM Transmission
    Peng, Wei-Ren
    Feng, Kai-Ming
    Chi, Sien
    2009 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1AND 2, 2009, : 471 - +
  • [36] Field-domain rapid-scan EPR at 240 GHz for studies of protein functional dynamics at room temperature
    Price, Brad D.
    Sojka, Antonin
    Maity, Shiny
    Chavez, I. Marcelo
    Starck, Matthieu
    Wilson, Maxwell Z.
    Han, Songi
    Sherwin, Mark S.
    JOURNAL OF MAGNETIC RESONANCE, 2024, 366
  • [37] RAPID-SCAN INFRARED FOURIER-TRANSFORM SPECTROSCOPY
    GRIFFITHS, PR
    FOSKETT, CT
    CURBELO, R
    APPLIED SPECTROSCOPY REVIEWS, 1972, 6 (01) : 31 - +
  • [38] Rapid frequency scan EPR
    Tseitlin, Mark
    Rinard, George A.
    Quine, Richard W.
    Eaton, Sandra S.
    Eaton, Gareth R.
    JOURNAL OF MAGNETIC RESONANCE, 2011, 211 (02) : 156 - 161
  • [39] Dynamic infrared spectroscopy using the rapid-scan technique
    Ekgasit, S
    Siesler, HW
    Steeman, PAM
    APPLIED SPECTROSCOPY, 1999, 53 (12) : 1535 - 1541
  • [40] RAPID-SCAN AREA-COVERAGE COMMUNICATION SATELLITE
    REUDINK, DO
    YEH, YS
    JOURNAL OF SPACECRAFT AND ROCKETS, 1980, 17 (01) : 9 - 14