An Early Investigation into Possible Alternatives to Stapled Hysterotomy in Open Fetal Surgery

被引:6
|
作者
Church, Joseph T. [1 ]
McLeod, Jennifer S. [1 ]
Coughlin, Megan A. [1 ]
Bergin, Ingrid L. [2 ]
Perkins, Elena M. [1 ]
Hoffman, Hayley R. [1 ]
Bilger, Mark [1 ]
Rojas-Pena, Alvaro [1 ]
Treadwell, Marjorie C. [3 ]
Berman, Deborah R. [3 ]
Jarboe, Marcus D. [4 ]
Mychaliska, George B. [4 ]
Perrone, Erin E. [4 ]
机构
[1] Univ Michigan, Extracorporeal Life Support Lab, Dept Surg, Michigan Med, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Unit Lab Anim Med, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Obstet & Gynecol, Fetal Diag & Treatment Ctr, Michigan Med, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Surg, Fetal Diag & Treatment Ctr, Michigan Med, Ann Arbor, MI 48109 USA
关键词
hysterotomy; prenatal; Harmonic; LigaSure; AutoSuturePremium Poly CS*-57 Stapler; surgical energy; HARMONIC SCALPEL; REPRODUCTIVE OUTCOMES; MATERNAL MORBIDITY; THYROID-SURGERY; HEMOSTASIS; LIGASURE; METAANALYSIS;
D O I
10.1055/s-0038-1673664
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery. Study Design Initial studies compared the LigaSure Impact and Harmonic ACE+7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term=145; n =7) underwent hysterotomy using either device. Hysterotomy edges were resected, and thermal injury extent was determined by histopathological assessment. Upon determining a superior device, subsequent studies compared this to the AutoSuture Premium Poly CS*-57 Stapler in uterine healing. Pregnant ewes ( n =6) at an EGA of 87 to 93 days underwent 6-cm hysterotomy in each gravid horn with either the stapler ( n =5) or Harmonic ( n =5) followed by closure and animal recovery. After 37 to 42 days, uterine healing was assessed by evaluating tensile strength and histopathology. Results Thermal damage was more extensive with the LigaSure ( n =11 hysterotomies) than with the Harmonic ( n =11; 5.61 vs. 3.1 +/- 0.6mm; p <0.0001);therefore, the Harmonic was selected for healing studies. Gross scar appearance and tensile strength were the same between the Harmonic and stapler. The stapler caused more fibrosis (4/7 samples with moderate fibrosis vs. 0/8 with the Harmonic; p =0.02). Conclusion The Harmonic ACE+7 caused less thermal injury than the LigaSure Impact and performed similar to the CS*-57 Stapler in uterine healing with continued gestation.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 50 条
  • [41] Impact of continuous intraoperative monitoring on outcomes in open fetal surgery
    Keswani, SG
    Crombleholme, TM
    Rychik, J
    Tian, ZY
    MacKenzie, TC
    Johnson, MP
    Wilson, RD
    Flake, AW
    Hedrick, HL
    Howell, LJ
    Adzick, NS
    FETAL DIAGNOSIS AND THERAPY, 2005, 20 (04) : 316 - 320
  • [42] Fetal Surgery for Open Spina Bifida in Canada: Initial Results
    Pruthi, Vagisha
    Abbasi, Nimrah
    Ryan, Greg
    Drake, James
    Kulkarni, Abhaya, V
    Kwan-Wong, Terence
    Phillips, John
    Thakur, Varsha
    Church, Paige
    Diambomba, Yenge
    Kelly, Edmond
    Vermeersch, Leslie
    Pollard, Lindsay
    Carvalho, Jose C. A.
    Van Mieghem, Tim
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2021, 43 (06) : 733 - +
  • [43] Uterine Defect after Open Maternal-fetal Surgery
    Ting, Paxton
    Sanders, Ari P.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2021, 28 (04) : 739 - 740
  • [44] In Utero Treatment of Meningomyelocele: Open and Minimally Invasive Fetal Surgery
    Belfort, M. A.
    BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2016, 106 (05) : 362 - 362
  • [45] Fetal surgery for open neural tube defect with severe ventriculomegaly
    Mitts, M. D.
    Whitehead, W.
    Corroenne, R.
    Johnson, R.
    Donepudi, R.
    Espinoza, J.
    Shamshirsaz, A. A.
    Sanz Cortes, M.
    Belfort, M. A.
    Nassr, A. A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2024, 64 (01) : 65 - 70
  • [46] THE INCIDENCE AND SPECTRUM OF NEUROLOGICAL INJURY AFTER OPEN FETAL SURGERY
    BEALER, JF
    RAISANEN, J
    SKARSGARD, ED
    LONG, SR
    WONG, K
    FILLY, RA
    ADZICK, NS
    HARRISON, MR
    JOURNAL OF PEDIATRIC SURGERY, 1995, 30 (08) : 1150 - 1154
  • [47] Early fetal megacystis: Is it possible to predict the prognosis in the first trimester?
    Iuculano, Ambra
    Peddes, Cristina
    Monni, Giovanni
    JOURNAL OF PERINATAL MEDICINE, 2018, 46 (09) : 1035 - 1039
  • [48] Prima del Traite? possible alternatives for the study of the corporeality of the early Nineteenth century
    Ligore, Bruno
    RICERCHE DI S-CONFINE, 2019, : 21 - 36
  • [49] Conventional Open Surgery in Early Gastric Cancer
    Noh, Sung Hoon
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2010, 53 (04): : 306 - 310
  • [50] Early extubation after open heart surgery
    MA Umre
    K Kumar
    A Saraswat
    S Kalra
    S Singh
    HJ Prasad
    Indian Journal of Thoracic and Cardiovascular Surgery, 2006, 22 (1) : 83 - 83