Cone beam computed tomography-based models versus multislice spiral computed tomography-based models for assessing condylar morphology

被引:11
|
作者
Gomes, Liliane Rosas [1 ,2 ]
Gomes, Marcelo Regis
Goncalves, Joao Roberto [1 ]
Ruellas, Antonio Carlos O. [3 ]
Wolford, Larry M. [4 ,5 ]
Paniagua, Beatriz [6 ]
Benavides, Erika [7 ]
Cevidanes, Lucia Helena Soares [2 ]
机构
[1] UNESP Univ Estadual Paulista, Fac Odontol Araraquara, Dept Orthodont, BR-14801903 Sao Paulo, Brazil
[2] Univ Michigan, Sch Dent, Dept Orthodont, Ann Arbor, MI 48109 USA
[3] Univ Fed Rio de Janeiro, Dept Orthodont, Rio De Janeiro, Brazil
[4] Baylor Univ, Med Ctr, Dept Oral & Maxillofacial Surg, A&M Univ,Hlth Sci Ctr,Baylor Coll Dent, Dallas, TX USA
[5] Baylor Univ, Med Ctr, Dept Orthodont, A&M Univ,Hlth Sci Ctr,Baylor Coll Dent, Dallas, TX USA
[6] Univ N Carolina, Dept Psychiat, Chapel Hill, NC USA
[7] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
基金
巴西圣保罗研究基金会; 美国国家卫生研究院;
关键词
DIFFERENT VOXEL RESOLUTIONS; VERTICAL ROOT FRACTURES; TOTAL JOINT PROSTHESIS; MANDIBULAR CONDYLE; MULTIDETECTOR CT; ORTHOGNATHIC SURGERY; DIAGNOSTIC-ACCURACY; LINEAR MEASUREMENTS; OSSEOUS CHANGES; IMAGE-ANALYSIS;
D O I
10.1016/j.oooo.2015.10.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To quantitatively compare condylar morphology using cone beam computed tomography (CBCT) and multislice spiral computed tomography (MSCT) virtual three-dimensional surface models. Study Design. The sample consisted of secondary data analyses of CBCT and MSCT scans obtained for clinical purposes from 74 patients treated with condylar resection and prosthetic joint replacement. Three-dimensional surface models of 146 condyles were constructed from each scan modality. Across-subject models were approximated and voxel-based registration was performed between homologous CBCT and MSCT images, making it possible to create average CBCT- and MSCT-based condylar models. SPHARM-PDM software provided matching points on each corresponding model. Shape Analysis MANCOVA software assessed statistically significant differences between observers and imaging modalities. One-sample t-tests evaluated the null hypothesis that the mean differences between each CBCT-and MSCT-based model were not clinically significant (<.5 mm). Tests were conducted at a significance level of P<.05. Results. Shape Analysis MANCOVA showed no statistically significant difference between the average CBCT-and MSCT-based models (P>.68). During pairwise comparison, the mean difference observed was .406 mm (SD, .173). One sample t-test showed that mean differences between each set of paired CBCT-and MSCT-based models were not clinically significant (P=.411). Conclusion. Three-dimensional surface models constructed from CBCT images are comparable to those derived from MSCT scans and may be considered reliable tools for assessing condylar morphology.
引用
收藏
页码:96 / 105
页数:10
相关论文
共 50 条
  • [21] Altered passive eruption diagnosis and treatment: a cone beam computed tomography-based reappraisal of the condition
    Batista, Eraldo L., Jr.
    Moreira, Carla C.
    Batista, Felipe C.
    de Oliveira, Rafael R.
    Pereira, Karina K. Y.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (11) : 1089 - 1096
  • [22] Evaluation of Cone-Beam Computed Tomography-Based Radiomic Features Reproducibility: A Phantom Study
    Adachi, T.
    Nakamura, M.
    Iramina, H.
    Mizowaki, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy
    Tsai, Pingfang
    Tseng, Yu-Lun
    Shen, Brian
    Ackerman, Christopher
    Zhai, Huifang A.
    Yu, Francis
    Simone II, Charles B.
    Choi, J. Isabelle
    Lee, Nancy Y.
    Kabarriti, Rafi
    Lazarev, Stanislav
    Johnson, Casey L.
    Liu, Jiayi
    Chen, Chin-Cheng
    Lin, Haibo
    CANCERS, 2023, 15 (20)
  • [24] Advances in computed tomography-based evaluation of coronary arteries: A review of coronary artery imaging with multidetector spiral computed tomography
    Chien, Christopher
    Feng, Yan-Fu
    Arora, Rohit R.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2007, 8 (02) : 53 - 60
  • [25] The Feasibility of Condylar Screws for Occipitocervical Fusion in Arabs: Computed Tomography-Based Morphometric Study
    Marwan, Yousef
    Jarragh, Ali
    Algarni, Nizar
    Sheikh, Mehraj
    Alsaeed, Osama
    GLOBAL SPINE JOURNAL, 2024,
  • [26] Computed tomography-based surgical navigation for hip arthroplasty
    Ecker, Tiyno M.
    Tannast, Moritz
    Murphy, Stephen B.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) : 100 - 105
  • [27] Neuroanatomy of stroke: A computed tomography-based topographic analysis
    Subhadarsini, Sonali
    Shani, Aboobacker Sait
    Mishra, Dharma Niranjan
    JOURNAL OF THE ANATOMICAL SOCIETY OF INDIA, 2023, 72 (02) : 145 - 150
  • [28] Postoperative computed tomography-based control of syndesmotic screws
    Schwarz N.
    Köfer E.
    European Journal of Trauma, 2005, 31 (3): : 266 - 270
  • [29] Computed tomography-based navigation for curved periacetabular osteotomy
    Akiyama, Haruhiko
    Goto, Koji
    So, Kazutaka
    Nakamura, Takashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (06) : 829 - 833
  • [30] Cone-beam computed tomography-based radiomics in prostate cancer: a mono-institutional study
    Bosetti, Davide Giovanni
    Ruinelli, Lorenzo
    Piliero, Maria Antonietta
    van der Gaag, Linda Christina
    Pesce, Gianfranco Angelo
    Valli, Mariacarla
    Bosetti, Marco
    Presilla, Stefano
    Richetti, Antonella
    Deantonio, Letizia
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (10) : 943 - 951