Characterization of the impact to PET quantification and image quality of an anterior array surface coil for PET/MR imaging

被引:22
|
作者
Wollenweber, Scott D. [1 ]
Delso, Gaspar [1 ,2 ]
Deller, Timothy [1 ]
Goldhaber, David [1 ]
Huellner, Martin [2 ]
Veit-Haibach, Patrick [2 ]
机构
[1] GE Healthcare, Waukesha, WI 53186 USA
[2] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
关键词
Positron-emission tomography; Magnetic resonance imaging; Attenuation correction; ATTENUATION CORRECTION; TIME;
D O I
10.1007/s10334-013-0388-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Object The aim of this study was to determine the impact to PET quantification, image quality and possible diagnostic impact of an anterior surface array used in a combined PET/MR imaging system. Materials and methods An extended oval phantom and 15 whole-body FDG PET/CT subjects were re-imaged for one bed position following placement of an anterior array coil at a clinically realistic position. The CT scan, used for PET attenuation correction, did not include the coil. Comparison, including liver SUVmean, was performed between the coil present and absent images using two methods of PET reconstruction. Due to the time delay between PET scans, a model was used to account for average physiologic time change of SUV. Results On phantom data, neglecting the coil caused a mean bias of -8.2 % for non-TOF/PSF reconstruction, and -7.3 % with TOF/PSF. On clinical data, the liver SUV neglecting the coil presence fell by -6.1 % (+/- 6.5 %) for non-TOF/PSF reconstruction; respectively-5.2 %(+/- 5.3 %) with TOF/PSF. All FDG-avid features seen with TOF/PSF were also seen with non-TOF/PSF reconstruction. Conclusion Neglecting coil attenuation for this anterior array coil results in a small but significant reduction in liver SUVmean but was not found to change the clinical interpretation of the PET images.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [21] Impact of MR-based PET motion correction on the quantification of PET kinetic parameters in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ebrahimi, Behzad
    Reese, Timothy
    Guehl, Nicolas
    Normandin, Marc
    Alpert, Nathaniel
    El Fakhri, Georges
    Ouyang, Jinsong
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [22] Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging
    Gratz, Marcel
    Ruhlmann, Verena
    Umutlu, Lale
    Fenchel, Matthias
    Hong, Inki
    Quick, Harald H.
    PLOS ONE, 2020, 15 (06):
  • [23] The Effect of TOF Technology on PET Image Quality of Integrated PET/MR Equipment
    Dong, Shuo
    Li, Dong
    Wu, Tianqi
    Wu, Ping
    Xie, Feng
    Zhuang, Jingwen
    Bai, Mei
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [24] A PET/MR coil with an integrated, orbiting 511 keV transmission source for PET/MR imaging validated in an animal study
    Renner, Andreas
    Rausch, Ivo
    Gonzalez, Jacobo Cal
    Laistler, Elmar
    Moser, Ewald
    Jochimsen, Thies
    Sattler, Tatjana
    Sabri, Osama
    Beyer, Thomas
    Figl, Michael
    Birkfellner, Wolfgang
    Sattler, Bernhard
    MEDICAL PHYSICS, 2022, 49 (04) : 2366 - 2372
  • [25] Effects of MR-Invisible Objects and Object Attenuation on PET Quantification in Small Animal PET/MR Imaging
    Bezrukov, Ilja
    Wehrl, Hans F.
    Liu, Chih-Chieh
    Hossain, Mosaddek
    Mantlik, Frederic
    Pichler, Bernd J.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study
    Tellmann, L.
    Quick, H. H.
    Bockisch, A.
    Herzog, H.
    Beyer, T.
    MEDICAL PHYSICS, 2011, 38 (05) : 2795 - 2805
  • [27] A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer
    Dregely, Isabel
    Lanz, Titus
    Metz, Stephan
    Mueller, Matthias F.
    Kuschan, Marika
    Nimbalkar, Manoj
    Bundschuh, Ralph A.
    Ziegler, Sibylle I.
    Haase, Axel
    Nekolla, Stephan G.
    Schwaiger, Markus
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 1154 - 1161
  • [28] PET/MR imaging of bone lesions – implications for PET quantification from imperfect attenuation correction
    Andrei Samarin
    Cyrill Burger
    Scott D. Wollenweber
    David W. Crook
    Irene A. Burger
    Daniel T. Schmid
    Gustav K. von Schulthess
    Felix P. Kuhn
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 1154 - 1160
  • [29] PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction
    Samarin, Andrei
    Burger, Cyrill
    Wollenweber, Scott D.
    Crook, David W.
    Burger, Irene A.
    Schmid, Daniel T.
    von Schulthess, Gustav K.
    Kuhn, Felix P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (07) : 1154 - 1160
  • [30] Metal implants appear to be less detrimental to the PET quality in PET/MR than in PET/CT imaging
    Beyer, T.
    Keller, S.
    Hansen, A.
    Loft, A.
    Lofgren, J.
    Hojgaard, L.
    Holm, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S231 - S231