Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

被引:13
|
作者
Conti, C. C. [1 ,2 ]
Anjos, M. J. [2 ]
Salgado, C. M. [3 ]
机构
[1] Inst Radioprotecao & Dosimetria IRD CNEN, BR-22783127 Rio De Janeiro, Brazil
[2] State Univ Rio de Janeiro UERJ, Inst Phys, Rio De Janeiro, Brazil
[3] Nucl Engn Inst IEN CNEN, Rio De Janeiro, Brazil
关键词
MCNP5; X-ray; Fluorescence; Mass attenuation coefficient; EFFECTIVE ATOMIC-NUMBER; HPGE DETECTOR; RADIATION; COHERENT; MCNP5;
D O I
10.1016/j.nimb.2014.06.004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [21] A NOVEL METHOD FOR THE DETERMINATION OF X-RAY-MASS ATTENUATION COEFFICIENTS
    KERUR, BR
    THONTADARYA, SR
    HANUMAIAH, B
    APPLIED RADIATION AND ISOTOPES, 1991, 42 (06) : 571 - 575
  • [22] Rayleigh to Compton ratio with monochromatic radiation from an X-ray tube (preliminary results)
    Donativi, M.
    Quarta, S.
    Cesareo, R.
    Castellano, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (01): : 189 - 193
  • [23] Measurement of the K X-ray absorption jump ratio of erbium by attenuation of a Compton peak
    Ayala, AP
    Mainardi, RT
    RADIATION PHYSICS AND CHEMISTRY, 1996, 47 (02): : 177 - 181
  • [24] Effects in K X-ray fluorescence spectra due to Compton scattering in the target
    Uroic, M.
    Majer, M.
    Pasic, S.
    Bokulic, T.
    Vukovic, B.
    Ilakovac, K.
    RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (11) : 1693 - 1697
  • [25] Assessing the Accuracy of Mass Attenuation Coefficients for Soft X-ray EPMA
    Llovet, Xavier
    Poeml, Philipp
    Moy, Aurelien
    Fournelle, John H.
    MICROSCOPY AND MICROANALYSIS, 2023, 29 (02) : 540 - 551
  • [26] Correction for beam attenuation and indirect excitation in x-ray fluorescence holography
    Dul, D. T.
    Dabrowski, K. M.
    Korecki, P.
    EPL, 2013, 104 (06)
  • [28] New consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique
    Chantler, C. T.
    Islam, M. T.
    Rae, N. A.
    Tran, C. Q.
    Glover, J. L.
    Barnea, Z.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2012, 68 : 188 - 195
  • [29] Anomalous nonlinear X-ray Compton scattering
    Fuchs, Matthias
    Trigo, Mariano
    Chen, Jian
    Ghimire, Shambhu
    Shwartz, Sharon
    Kozina, Michael
    Jiang, Mason
    Henighan, Thomas
    Bray, Crystal
    Ndabashimiye, Georges
    Bucksbaum, Philip H.
    Feng, Yiping
    Herrmann, Sven
    Carini, Gabriella A.
    Pines, Jack
    Hart, Philip
    Kenney, Christopher
    Guillet, Serge
    Boutee, Sebastien
    Williams, Garth J.
    Messerschmidt, Marc
    Seibert, M. Marvin
    Moeller, Stefan
    Hastings, Jerome B.
    Reis, David A.
    NATURE PHYSICS, 2015, 11 (11) : 964 - 970
  • [30] Correction for X-ray absorption in compton tomography
    Golosio, B
    Brunetti, A
    Cesareo, R
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 651 - 654